The possibility of applying the standard calculation of the shear force of thin high-coercive neodymium— iron—boron permanent magnets in magnetic systems and magnetic couplings is considered. A correction factor is proposed for calculating the shear force in systems with thin magnets, which allows at the stage of developing sealed equipment to calculate the shear force of permanent magnets in these systems.
Keywords: magnetic system, magnetic coupling, permanent magnet, shear force.