Low energy excitation in liquid Sb and liquid Bi observed in inelastic x-ray scattering spectra

2021 ◽  
Vol 33 (47) ◽  
pp. 475101
Author(s):  
M Inui ◽  
Y Kajihara ◽  
S Hosokawa ◽  
A Chiba ◽  
Y Nakajima ◽  
...  
2008 ◽  
Vol 354 (19-25) ◽  
pp. 2669-2672 ◽  
Author(s):  
Kiyoto Matsuishi ◽  
Shinya Hosokawa ◽  
Satoshi Tsutsui ◽  
Alfred Q.R. Baron

2020 ◽  
Vol 27 (4) ◽  
pp. 963-969
Author(s):  
J.-K. Kim ◽  
Diego Casa ◽  
Xianrong Huang ◽  
Thomas Gog ◽  
B. J. Kim ◽  
...  

Resonant inelastic X-ray scattering (RIXS) is increasingly playing a significant role in studying highly correlated systems, especially since it was proven capable of measuring low-energy magnetic excitations. However, despite high expectations for experimental evidence of novel magnetic phases at high pressure, unequivocal low-energy spectral signatures remain obscured by extrinsic scattering from material surrounding the sample in a diamond anvil cell (DAC): pressure media, Be gasket and the diamond anvils themselves. A scattered X-ray collimation based medium-energy resolution (∼100 meV) analyzer system for a RIXS spectrometer at the Ir L 3-absorption edge has been designed and built to remediate these difficulties. Due to the confocal nature of the analyzer system, the majority of extrinsic scattering is rejected, yielding a clean low-energy excitation spectrum of an iridate Sr2IrO4 sample in a DAC cell. Furthermore, the energy resolution of different configurations of the collimating and analyzing optics are discussed.


2019 ◽  
Vol 27 (5) ◽  
pp. 857-870 ◽  
Author(s):  
M.M. Barysheva ◽  
N.I. Chkhalo ◽  
M.N. Drozdov ◽  
M.S. Mikhailenko ◽  
A.E. Pestov ◽  
...  

1998 ◽  
Vol 5 (3) ◽  
pp. 1052-1054 ◽  
Author(s):  
Hisashi Hayashi ◽  
Noboru Watanabe ◽  
Yasuo Udagawa

Inelastic X-ray scattering spectra of liquid water and cyclohexane have been measured with 2 eV resolution for a momentum transfer range between 0.69 and 2.77 au at BL16A of the Photon Factory, KEK, Tsukuba. Observed spectra are transformed to the dynamic structure factor which is normalized by using the Bethe sum rule, and the static structure factor is obtained. From a comparison with extended CI calculations by the use of various basis sets, correlation effects are proved to be of vital importance in inelastic X-ray scattering.


2000 ◽  
Vol 61 (2) ◽  
pp. 1518-1526 ◽  
Author(s):  
C. Y. Liao ◽  
S. H. Chen ◽  
F. Sette

1999 ◽  
Vol 101-103 ◽  
pp. 573-578 ◽  
Author(s):  
M. Magnuson ◽  
L. Yang ◽  
J.-H. Guo ◽  
C. Såthe ◽  
A. Agui ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document