scholarly journals Construction and simulation bias study of the guide Tube Calibration System for JUNO

2021 ◽  
Vol 16 (07) ◽  
pp. T07005
Author(s):  
Yuhang Guo ◽  
Kangfu Zhu ◽  
Qingmin Zhang ◽  
Feiyang Zhang ◽  
Yue Meng ◽  
...  
2019 ◽  
Vol 14 (09) ◽  
pp. T09005-T09005
Author(s):  
Yuhang Guo ◽  
Qingmin Zhang ◽  
Feiyang Zhang ◽  
Mengjiao Xiao ◽  
Jianglai Liu ◽  
...  

Author(s):  
Arthur J. Wasserman ◽  
Azam Rizvi ◽  
George Zazanis ◽  
Frederick H. Silver

In cases of peripheral nerve damage the gap between proximal and distal stumps can be closed by suturing the ends together, using a nerve graft, or by nerve tubulization. Suturing allows regeneration but does not prevent formation of painful neuromas which adhere to adjacent tissues. Autografts are not reported to be as good as tubulization and require a second surgical site with additional risks and complications. Tubulization involves implanting a nerve guide tube that will provide a stable environment for axon proliferation while simultaneously preventing formation of fibrous scar tissue. Supplementing tubes with a collagen gel or collagen plus extracellular matrix factors is reported to increase axon proliferation when compared to controls. But there is no information regarding the use of collagen fibers to guide nerve cell migration through a tube. This communication reports ultrastructural observations on rat sciatic nerve regeneration through a silicone nerve stent containing crosslinked collagen fibers.Collagen fibers were prepared as described previously. The fibers were threaded through a silicone tube to form a central plug. One cm segments of sciatic nerve were excised from Sprague Dawley rats. A control group of rats received a silicone tube implant without collagen while an experimental group received the silicone tube containing a collagen fiber plug. At 4 and 6 weeks postoperatively, the implants were removed and fixed in 2.5% glutaraldehyde buffered by 0.1 M cacodylate containing 1.5 mM CaCl2 and balanced by 0.1 M sucrose. The explants were post-fixed in 1% OSO4, block stained in 1% uranyl acetate, dehydrated and embedded in Epon. Axons were counted on montages prepared at a total magnification of 1700x. Montages were viewed through a dissecting microscope. Thin sections were sampled from the proximal, middle and distal regions of regenerating sciatic plugs.


1985 ◽  
Vol 5 (3) ◽  
pp. 273-278
Author(s):  
Yuichi Hashishin ◽  
Uichi Kubo
Keyword(s):  

Author(s):  
M. Jurek ◽  
R. Wagnerová

AbstractLaser engraving of photographs on wood surfaces is a challenging task. To optimize the outcome and production quality it is necessary to control every aspect of the laser engraving process. Most of the production machines and technologies overall are mainly focused on laser power control. However, with other systems and deeper knowledge of the wood characteristics it is possible to achieve even better quality. This paper deals with enlarging the number of achievable shades of burned wood and its optimization. A calibration system was developed to control colour shades of engraved wood with a combination of laser power and optic focus. With this approach it is possible to widen achievable palette of engraved shades by continuous control of chemical processes of laser and wood interaction. The production is divided into wood burning and wood carbonization by variation of laser beam focus.


2012 ◽  
Vol 36 (4) ◽  
pp. 334-338 ◽  
Author(s):  
Fei Jia ◽  
Yong-Wei Dong ◽  
Jun-Ying Chai ◽  
Jiang-Tao Liu ◽  
Bo-Bing Wu ◽  
...  

IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 62592-62605 ◽  
Author(s):  
Bin Tian ◽  
Kun Mean Hou ◽  
Xunxing Diao ◽  
Hongling Shi ◽  
Haiying Zhou ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document