A High-Performance Liquid Chromatographic Method for the Determination of Meropenem in Serum

2019 ◽  
Vol 58 (2) ◽  
pp. 144-150
Author(s):  
Demet Dincel ◽  
Olcay Sagirli ◽  
Gulacti Topcu

Abstract In this study, a new, sensitive and selective high-performance liquid chromatographic method was developed for the determination of meropenem (MEM) in human serum. In the developed method, C18 column (3.9 × 150 mm, 5 μm) was selected as stationary phase at 30°C, and methanol: acetic acid solution mixture was used as mobile phase with gradient program. Chromatographic separation was carried out at a flow rate of 1 mL/min, and detection was performed at 300 nm with diode array detector. Doripenem was selected as an internal standard, and the analytes were extracted from serum using protein precipitation method with ortho-phosphoric acid: methanol. Detection wavelength was selected as 300 nm. The developed method was validated according to International Council for Harmonisation (ICH) guidelines. The calibration curve was linear over a concentration range of 4–240 μg/mL with correlation coefficient of 0.9985. The limit of detection and limit of quantification values were found as 0.057 and 0.192 μg/mL, respectively. The validated method was successfully applied for the determination of MEM in human serum samples collected from patient volunteers at different time intervals, and therapeutic drug monitoring of MEM has been investigated.

2008 ◽  
Vol 91 (1) ◽  
pp. 67-72 ◽  
Author(s):  
Juliana Sippel ◽  
Letcia L Sfair ◽  
Elfrides E S Schapoval ◽  
Martin Steppe

Abstract A new high-performance liquid chromatographic method was developed and validated for clopidogrel determination in pharmaceutical formulations. The system consisted of an ACE 5 octadecylsilane (C18; 150 4.6 mm id), 5.0 m particle size column; methanol0.1 triethylamine (75 + 25, v/v), pH 5.3, mobile phase at a flow rate of 1.2 mL/min; and a diode array detector set at 220 nm. Specificity, linearity, precision, accuracy, and robustness were the parameters evaluated. The retention time for clopidogrel was 6.8 min. To estimate specificity, an aqueous sample solution was subjected to degradation by ultraviolet light and by acid, alkaline, and oxidation media. The peaks of degradation products did not interfere with the compound signal, and there was no interference when a placebo solution was analyzed. Linearity over a concentration range of 10.0 to 90.0 g/mL was shown (correlation coefficient = 0.9998). Low values of relative standard deviation indicated the adequate intraday and interday precision. The average recovery was found as 99.16. In the robustness test, small modifications to the mobile phase composition did not affect the determination of clopidogrel. The proposed method proved to be simple, fast, and cost efficient for the intended use.


Sign in / Sign up

Export Citation Format

Share Document