A new approach to the quality control of steroid receptor assays.

1988 ◽  
Vol 34 (10) ◽  
pp. 2076-2079
Author(s):  
M Borsotti ◽  
M Quercioli ◽  
R D'Ettole ◽  
A Piffanelli ◽  
G Messeri

Abstract Lyophilized cytosols prepared from calf uterus and human breast tumor tissue are commonly used to assess the reliability of routine steroid receptor assays. However, preanalytical error (sample preparation, storage, homogenization) cannot be detected in this way. Participating laboratories were asked to mail us all their receptor results obtained over a four-month interval, and to include some information about the patients involved (age, menopausal status, nodal status). After verifying the homogeneity of the populations investigated, we computed consensus means for the percentages of positive samples and for their absolute value. Despite the homogeneity of the characteristics of the populations studied, results from some laboratories systematically differed from the consensus mean. This approach to the quality control of steroid receptors allows evaluation of the whole procedure, from sample preparation to analysis, and thus may be helpful as an addition to the usual practice of distribution of cytosols and tissue powders for assay.

1988 ◽  
Vol 3 (1) ◽  
pp. 69-69
Author(s):  
M. Borsotti ◽  
R. D'Ettole ◽  
G. Messeri ◽  
M. Quercioli ◽  
A. Piffanelli

Author(s):  
Hua Younan

Abstract In wafer fabrication (Fab), Fluorine (F) based gases are used for Al bondpad opening process. Thus, even on a regular Al bondpad, there exists a low level of F contamination. However, the F level has to be controlled at a lower level. If the F level is higher than the control/spec limits, it could cause F-induced corrosion and Al-F defects, resulting in pad discoloration and NSOP problems. In our previous studies [1-5], the theories, characteristics, chemical and physical failure mechanisms and the root causes of the F-induced corrosion and Al-F defects on Al bondpads have been studied. In this paper, we further study F-induced corrosion and propose to establish an Auger monitoring system so as to monitor the F contamination level on Al bondpads in wafer fabrication. Auger monitoring frequency, sample preparation, wafer life, Auger analysis points, control/spec limits and OOC/OOS quality control procedures are also discussed.


Cancer ◽  
2003 ◽  
Vol 98 (10) ◽  
pp. 2207-2213 ◽  
Author(s):  
Junko Uchikawa ◽  
Tanri Shiozawa ◽  
Hsien-Chang Shih ◽  
Tsutomu Miyamoto ◽  
Yu-Zhen Feng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document