P5981Impact of radiotherapy on myocardial function and paravalvular leaks after transcatheter aortic valve implantation (TAVI)

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M Cicenia ◽  
S Marchetta ◽  
R Dulgheru ◽  
F Ilardi ◽  
M Bouziane ◽  
...  

Abstract Introduction Thanks to the anticancer therapies, the life expectancy of the oncologic patients has noticeably increased, but several cardiac diseases can be observed in these patients as the result of the cardiotoxic effects. Purpose To investigate the impact of radiotherapy on the clinical and echocardiographic outcomes, in patients with severe aortic stenosis (AS) and preserved left ventricle ejection fraction (LVEF) treated with transcatheter aortic valve implantation (TAVI). Methods We recruited patients with severe AS and left ventricular ejection fraction (LVEF) ≥50‰ treated with TAVI and who received prior radiotheraphy. Patients with LVEF <50‰, treated with valve in valve, with inadequate acoustic windows or the absence of echocardiographic images pre-TAVI and after 3–6 months were excluded. Demographic, clinical and echocardiographic data were recorded. Results 102 patients were included in the present analysis. They were divided in two groups: 19 (18‰) with an oncologic history treated with previous left thoracic/mediastinal radiotherapy and 83 (82‰) patients without an oncologic history. The two groups were homogeneous in terms of demographic and clinical data, brain natriuretic peptide (BNP), echocardiographic data pre-TAVI. They only differed for a greater prevalence of mitral stenosis and calcifications in the oncologic patients versus the non-oncologics (respectively 36‰ vs. 12‰ p=0,016; 73‰ vs. 29‰ p=0,001). No differences in terms of in-hospital clinical outcomes were observed. The echocardiographic evaluation in both groups showed a significant decrease of the peak velocities and of the transprosthetic gradients. There was a higher incidence of at least moderate degree paraprosthetic leaks in the oncologic group vs. the non-oncologic one: 6 (31‰ total leaks, 37‰ leaks >2+) vs. 7 (8‰ total leaks, 12‰ leaks >2+); p=0.029. After 3–6 months, there was not a statistically significant improvement of ejection fraction (EF) in neither of the two groups but there was a statistically significant improvement of transmural, subepicardial and subendocardial longitudinal strain values in the non-oncologic group compared to pre-TAVI values, respectively −19±4 vs. −17±4 (p<0.001); −17±3 vs. −15±3 (p<0.001); −22±4 vs. −19.8±4 (p<0.001). Any statistically significant improvement was detected in the group with history of anticancer treatments between the longitudinal strain values post and pre-TAVI (−18±3‰ vs. −16±3‰; −14±3‰ vs. −20±5‰; −20 ±± 5‰ vs. −19±4‰). Conclusions Patients affected by severe AS treated with TAVI and who received received prior radiotheraphy, showed the absence of statistically significant improvement of multilayer strain values, at 3–6 months after TAVI. Oncologic patients also had a higher incidence of haemodynamically relevant paravalvular leaks after the intervention, compared to the non-oncologic patients.

Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2399
Author(s):  
Jeanne Martine Gunzinger ◽  
Burbuqe Ibrahimi ◽  
Joel Baur ◽  
Maximilian Robert Justus Wiest ◽  
Marco Picirelli ◽  
...  

Transcatheter aortic valve implantation (TAVI) is an alternative to open heart surgery in the treatment of symptomatic aortic valve stenosis, which is often the treatment of choice in elderly and frail patients. It carries a risk of embolic complications in the whole cerebral vascular bed, which includes the retinal vasculature. The main objective was the evaluation of retinal emboli visible on optical coherence tomography angiography (OCTA) following TAVI. This is a prospective, single center, observational study enrolling consecutive patients over two years. Patients were assessed pre- and post-TAVI. Twenty-eight patients were included in the final analysis, 82.1% were male, median age was 79.5 (range 52–88), median BCVA was 82.5 letters (range 75–93). Eight patients (28.6%) presented new capillary dropout lesions in their post-TAVI OCTA scans. There was no statistically significant change in BCVA. Quantitative analysis of macular or peripapillary OCTA parameters did not show any statistically significant difference in pre- and post-intervention. In conclusion, capillary dropout lesions could frequently be found in patients after TAVI. Quantitative measurements of macular and peripapillary flow remained stable, possibly indicating effective ocular blood flow regulation within the range of left ventricular ejection fraction in our cohort.


2021 ◽  
Vol 23 (Supplement_G) ◽  
Author(s):  
Isabella Leo ◽  
Jolanda Sabatino ◽  
Antonio Strangio ◽  
Sabrina La Bella ◽  
Sabato Sorrentino ◽  
...  

Abstract Aims A growing number of patients is undergoing transcatheter treatment of severe Aortic Stenosis. Changes in cardiac mechanics after removal of afterload in these patients are under-investigated. Myocardial Work (MW) is emerging as a useful non-invasive correlate of invasively measured myocardial performance and oxygen consumption. Aim of this study was to assess the usefulness of non-invasive MW indices in the clinical assessment of patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). Methods and results Consecutive patients with severe aortic stenosis referred for TAVI in a single tertiary centre were included. Echocardiography recordings (GE-Healthcare) with systolic and diastolic non-invasive pressures, were obtained immediately before TAVI and after TAVI to measure myocardial work index (MWI), myocardial constructive work (MCW), myocardial wasted work (MWW), and myocardial work efficiency (MWE). Consecutive patients with severe AS (n = 73) undergoing TAVI and matched controls (n = 50) were included. Mean transaortic gradient, AV area, and peak transvalvular velocity were significantly improved (all P &lt; 0.05). No changes in left ventricular ejection fraction nor in global longitudinal strain (GLS) were observed. GWI (P &lt; 0.001) and GCW (P &lt; 0.001) were significantly reduced after TAVI. On the contrary, we observed no significant change in GWW (P = 0.241) nor GWE (P = 0.854). Women had higher GWI (P = 0.007) and GCW (P = 0.014) compared to men, with a larger delta change of GCW. Patients with a low flow low gradient (LF-LG) AS had lower LVEF (P &lt; 0.001), worse GLS (P &lt; 0.001) and lower baseline GWI (P &lt; 0.001), GCW (P &lt; 0.001), and GWE (P = 0.003). The improvement in GWI and GCW observed after TAVI in the general study population were abolished among LF-LG patients. Conclusions The use of non-invasive myocardial work might be useful to further classify patients with AS and could be useful to predict non responders.


Author(s):  
hulya yilmaz ak ◽  
Yasemin Ozsahin ◽  
Kerem Erkalp ◽  
Ziya Salihoglu

Abstract: Backgraound: Transcatheter aortic valve implantation (TAVI), with its improved valve technologies will also be an option for patients in the near future and improved operator experience. Cerebrovascular events are among the most feared complications of TAVI, since they cause high morbidity and mortality. Case: After the patient with EuroSCORE II = 8.6% was considered to be at high risk in terms of surgery, the decision to perform TAVI was taken. The valve (Medtronic 26 mm) was successfully placed during the 110 min procedure. Blood loss was 140 mL, no red blood cell (RBC) transfusion and catecholamines requirements were present, no VF (ventricular fibrillation) and cardiac tamponade were observed and post procedure left ventricular ejection fraction (LVEF) was 60%. At the end of the procedure, the BIS value of the patient was 70, regression in the Glasgow Coma Score (GCS = 12), anisocoria in the pupils (R = 2 mm < L = 4 mm) and motor loss in the right arm (3/5) and right leg (3/5) were detected. Modified Rankin scale (mRS) was evaluated as 4. Conclusions: The neurological complication rate of up to 80% during and in the days following the procedure, the long recovery period after embolism, the possibility of being a nursing patient and even the risk of death, remind us that the TAVI procedure and the sedation given during the procedure should never be underestimated. Keywords: Transcatheter aortic valve implantation, cerebral embolism, complications, neuroradiology, monitorized anaesthesia care, aort stenosis.


Sign in / Sign up

Export Citation Format

Share Document