scholarly journals Analytical Method for Dimethenamid-P in Selected Raw Agricultural Commodities by Gas Chromatography with Electron Capture Detection

2005 ◽  
Vol 88 (5) ◽  
pp. 1428-1432
Author(s):  
Kim A Anderson ◽  
Jennifer L Basile ◽  
Eugene R Johnson

Abstract A sensitive and simple method for the extraction and quantification of the herbicide dimethenamid-P from several raw agricultural commodities (RAC) is presented. The method provides sensitive and well-defined chromatography with baseline resolution in all matrixes tested. Homogenized samples were extracted with methanol–water, filtered, and then extracted with hexanes. A Florisil solid-phase extraction was then applied for the final cleanup. Sample separation and quantification were performed by gas chromatography with an electron capture detector. The instrument detection limit was 0.007 μg/mL, and the practical quantification limit was 0.003 μg/g (w/w) based on a 25 g sample. Recoveries for a series of fortified plant tissues ranged from 69 to 103%. The study demonstrated selective and sensitive recovery of dimethenamid-P from the RAC tested.

2001 ◽  
Vol 84 (5) ◽  
pp. 1561-1568 ◽  
Author(s):  
Cristina Yagüe ◽  
Susana Bayarri ◽  
Regina Lázaro ◽  
Pilar Conchello ◽  
Agustín Ariño ◽  
...  

Abstract A multiresidue analytical method based on matrix solid-phase dispersion was developed to analyze liquid milk for 22 organochlorine pesticides (OCPs) and 6 polychlorinated biphenyls (PCBs). Initial extraction is performed by loading 3 mL milk onto a 2.0 g octadecyl (C18)-bonded silica cartridge with n-hexane as the eluant. Neutral alumina column chromatography with sodium sulfate as the drying agent is used for further cleanup. The eluate is concentrated to 0.5 mL, and target analytes are determined by capillary gas chromatography with electron-capture detection. The optimized method was validated by determining accuracy (recovery percentages), precision (repeatability and reproducibility), and sensitivity (detection and quantitation limits) from analyses of milk samples fortified at 10 and 1 μg/L levels. Average recoveries were between 74 and 106% for all residues except β-HCH, β-endosulfan, and endosulfan sulfate. Both repeatability and reproducibility relative standard deviation values were < 22% for all residues. Detection limits ranged from 0.02 to 0.12 μg/L and quantitation limits were between 0.02 and 0.62 μg/L. The proposed analytical method may be used as a fast and simple procedure in routine determinations of OCPs and PCBs in milk.


RSC Advances ◽  
2016 ◽  
Vol 6 (99) ◽  
pp. 96510-96517 ◽  
Author(s):  
Jhih-Ming Chen ◽  
Chun-Chuan Yang ◽  
Wu-Hsun Chung ◽  
Wang-Hsien Ding

This work represents the development of vortex-homogenized matrix solid-phase dispersion (VH-MSPD) as an effective and simple method to rapidly extract halogenated phenolic compounds in marketed seafood samples.