scholarly journals Quantitative Analysis of Three Chiral Pesticide Enantiomers by High-Performance Column Liquid Chromatography

2008 ◽  
Vol 91 (5) ◽  
pp. 1007-1012 ◽  
Author(s):  
Peng Wang ◽  
Donghui Liu ◽  
Xu Gu ◽  
Shuren Jiang ◽  
Zhiqiang Zhou

Abstract Methods for the enantiomeric quantitative determination of 3 chiral pesticides, paclobutrazol, myclobutanil, and uniconazole, and their residues in soil and water are reported. An effective chiral high-performance liquid chromatographic (HPLC)-UV method using an amylose-tris(3,5-dimethylphenylcarbamate; AD) column was developed for resolving the enantiomers and quantitative determination. The enantiomers were identified by a circular dichroism detector. Validation involved complete resolution of each of the 2 enantiomers, plus determination of linearity, precision, and limit of detection (LOD). The pesticide enantiomers were isolated by solvent extraction from soil and C18 solid-phase extraction from water. The 2 enantiomers of the 3 pesticides could be completely separated on the AD column using n-hexane isopropanol mobile phase. The linearity and precision results indicated that the method was reliable for the quantitative analysis of the enantiomers. LODs were 0.025, 0.05, and 0.05 mg/kg for each enantiomer of paclobutrazol, myclobutanil, and uniconazole, respectively. Recovery and precision data showed that the pretreatment procedures were satisfactory for enantiomer extraction and cleanup. This method can be used for optical purity determination of technical material and analysis of environmental residues.

2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


2012 ◽  
Vol 1 (12) ◽  
pp. 410-413 ◽  
Author(s):  
Sukhbir Lal Khokra ◽  
Balram Choudhary ◽  
Heena Mehta

A rapid, simple and highly sensitive reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed for the quantitative determination of Rabeprazole sodium and Aceclofenac in a combined dosage form. Rabeprazole sodium and Aceclofenac were chromatographed using C-18 column as stationary phase and methanol: acetonitrile: water (60 : 10 : 30 v/v/v) as the mobile phase at a flow rate of 1.0 ml/min at ambient temperature and detected at 280 nm. The retention time (RT) of Rabeprazole sodium and Aceclofenac were found to be 5.611 min and 2.102 minute, respectively. The linearities of Rabeprazole sodium and Aceclofenac were in the range of 1-10 µg/ml and 3-15 µg/ml, respectively. The limit of detection was found to be 0.091 µg/ml for Rabeprazole sodium and 0.043 µg/ml for Aceclofenac. The proposed method was applied for the determination of Rabeprazole sodium and Aceclofenac in a combined dosage form and result was found satisfactory.DOI: http://dx.doi.org/10.3329/icpj.v1i12.12450 International Current Pharmaceutical Journal 2012, 1(12): 410-413


2003 ◽  
Vol 68 (11) ◽  
pp. 883-892 ◽  
Author(s):  
Dragica Zendelovska ◽  
Trajce Stafilov

A rapid, specific and sensitive high-performance liquid chromatographic method for the determination of famotidine in human plasma has been developed. Famotidine and the internal standard were chromatographically separated from plasma components using a Lichrocart Lichrospher 60 RP select B cartridge for solid-phase separation with a mobile phase composed of 0.1 % (v/v) triethylamine in water (pH 3) and acetonitrile (92:8, v/v). UV detection was set at 270 nm. The calibration curve was linear in the concentration range of 10.0 ? 350.0 ng mL-1. The method was implemented to monitor the famotidine levels in patient samples.


Sign in / Sign up

Export Citation Format

Share Document