Serum Theophylline Determination by Isothermal Gas-Liquid Chromatography on 3% SP2250-DB

1978 ◽  
Vol 2 (1) ◽  
pp. 3-6 ◽  
Author(s):  
Carol A. Pranskevich ◽  
Janice I. Swihart ◽  
Jerry J. Thoma
1977 ◽  
Vol 23 (7) ◽  
pp. 1306-1309 ◽  
Author(s):  
R H Smith ◽  
J A MacDonald ◽  
D S Thompson ◽  
W E Flacke

Abstract We describe an isothermal gas-liquid chromatographic procedure developed for measuring thiamylal and thiopental in plasma. The unchanged drug is extracted into ethyl acetate from acidified plasma, together with an internal standard. The solvent is removed, the residue methylated, aliquots, diluted with benzene, are injected into a 183-cm gas-liquid chromatographic column containing 3% OV-17. Sensitivity of detection is in the nanogram to picogram range.


1970 ◽  
Vol 16 (2) ◽  
pp. 107-110 ◽  
Author(s):  
M A Evenson ◽  
P Jones ◽  
B Darcey

Abstract The need for simultaneous determination of the concentration of diphenylhydantoin (Dilantin) and primidone (Mysoline) in serum is frequently expressed to the clinical chemistry laboratory. Isothermal gas-liquid chromatography (GLC) has been used to develop a rapid, specific method. The method involves a single extraction and no derivative formation. The procedure is simple enough to be used with large numbers of samples. Detection limits for the method are 0.3 µg diphenylhydantoin per ml and 0.1 µg primidone per ml. The mean precision of the method is 6.2% and 4.8%, expressed as the coefficient of variation, for diphenylhydantoin and primidone, respectively. Barbiturates and glutethimide added to serum samples did not interfere with the analysis. The method has been used for more than 500 patients without interferences from metabolites, and meets all criteria for routine and emergency use.


1978 ◽  
Vol 24 (9) ◽  
pp. 1599-1602 ◽  
Author(s):  
R H Smith ◽  
M A Brewster ◽  
J A MacDonald ◽  
D S Thompson

Abstract We describe an isothermal gas-liquid chromatographic procedure developed for measuring procaine and chloroprocaine in plasma. The unchanged drug is extracted into toluene from alkalinized plasma, together with an internal standard. The solvent is removed, the residue redissolved in methanol, and aliquots are injected into a 91.5-cm gas-liquid chromatographic column containing 3% OV-210. Sensitivity of detection is in the nanogram range.


1974 ◽  
Vol 24 (11) ◽  
pp. 645-654 ◽  
Author(s):  
F. Alan Barbour ◽  
Richard V. Barbour ◽  
J. Claine Peterson

1971 ◽  
Vol 67 (2) ◽  
pp. 303-315 ◽  
Author(s):  
A. J. Moolenaar ◽  
A. P. van Seters

ABSTRACT The 17-oxosteroids were estimated in the urine of 27 patients with Cushing's syndrome by gas-liquid chromatography (G. L. C.). The values of the various steroid fractions are compared with those of normal subjects, patients with thyrotoxicosis and obese subjects. The effect of the age of the patients on the diagnostic value of the invidual 17-oxosteroids and their ratios is discussed.


Sign in / Sign up

Export Citation Format

Share Document