scholarly journals Radiographic Accuracy of Percutaneous Pedicle Screw Placement in Fluoroscopic- Versus CT Navigation-Guided Lumbar Spine Instrumentation

Neurosurgery ◽  
2019 ◽  
Vol 66 (Supplement_1) ◽  
Author(s):  
Guang-Ting Cong ◽  
Avani Vaishnav ◽  
Joseph Barbera ◽  
Hiroshi Kumagai ◽  
James Dowdell ◽  
...  

Abstract INTRODUCTION Posterior spinal instrumentation for fusion using intraoperative computed tomography (CT) navigation is gaining traction as an alternative to the conventional two-dimensional fluoroscopic-guided approach to percutaneous pedicle screw placement. However, few studies to date have directly compared outcomes of these 2 minimally invasive instrumentation methods. METHODS A consecutive cohort of patients undergoing primary percutaneous posterior lumbar spine instrumentation for spine fusion was retrospectively reviewed. Revision surgeries or cases converted to open were excluded. Accuracy of screw placement was assessed using a postoperative CT scan with blinding to the surgical methods used. The Gertzbein-Robbins classification was used to grade cortical breach: Grade 0 (<0 mm cortical breach), Grade I (<2 mm), Grade II (2-4 mm), Grade III (4-6 mm), and Grade IV (>6 mm). RESULTS CT navigation was found to significantly improve accuracy of screw placement (P < .022). There was significantly more facet violation of the unfused level in the fluoroscopy group vs the CT group (9% vs 0.5%; P < .0001). There was also a higher proportion of poor screw placement in the fluoroscopy group (10.1% vs 3.6%). No statistical difference was found in the rate of tip breach, inferomedial breach, or lateral breach. Regression analysis showed that fluoroscopy had twice the odds of incurring poor screw placement as compared to CT navigation. CONCLUSION This radiographic study comparing screw placement in minimally invasive fluoroscopy- vs CT navigation-guided lumbar spine instrumentation provides evidence that CT navigation significantly improves accuracy of screw placement, especially in optimizing the screw trajectory so as to avoid facet violation. Long-term follow-up studies should be performed to ascertain whether this difference can contribute to an improvement in clinical outcomes.

2017 ◽  
Vol 43 (2) ◽  
pp. E9 ◽  
Author(s):  
Brandon W. Smith ◽  
Jacob R. Joseph ◽  
Michael Kirsch ◽  
Mary Oakley Strasser ◽  
Jacob Smith ◽  
...  

OBJECTIVEPercutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy.METHODSPatients undergoing PPSI utilizing the K-wire–less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement.RESULTSThirty-six patients (18 male and 18 female) were included. The patients’ mean age was 60.4 years (range 23.8–78.4 years), and their mean body mass index was 28.5 kg/m2 (range 20.8–40.1 kg/m2). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4–14) were placed over a mean of 2.61 levels (range 1–7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort.CONCLUSIONSThis streamlined 2-step K-wire–less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.


Neurosurgery ◽  
2011 ◽  
Vol 70 (4) ◽  
pp. 990-995 ◽  
Author(s):  
John K. Houten ◽  
Rani Nasser ◽  
Nrupen Baxi

Abstract BACKGROUND: Increasing popularity of minimally invasive surgery for lumbar fusion has led to dependence upon intraoperative fluoroscopy for pedicle screw placement, because limited muscle dissection does not expose the bony anatomy necessary for traditional, freehand techniques nor for registration steps in image-guidance techniques. This has raised concerns about cumulative radiation exposure for both surgeon and operating room staff. The recent introduction of the O-arm Multidimensional Surgical Imaging System allows for percutaneous placement of pedicle screws, but there is limited clinical experience with the technique and data examining its accuracy. OBJECTIVE: We present the first large clinical series of percutaneous screw placement using navigation of O-arm imaging and compare the results with the fluoroscopy-guided method. METHODS: A retrospective review of a 24-month period identified patients undergoing minimally invasive lumbar interbody fusion. The O-arm was introduced in the middle of this period and was used for all subsequent patients. Accuracy of screw placement was assessed by examination of axial computed tomography or O-arm scans. RESULTS: The fluoroscopy group included 141 screws in 42 patients, and the O-arm group included 205 screws in 52 patients. The perforation rate was 12.8% in the fluoroscopy group and 3% in the O-arm group (P &lt; .001). Single-level O-arm procedures took a mean 200 (153–241) minutes, whereas fluoroscopy took 221 (178–302) minutes (P &lt; .03). CONCLUSION: Percutaneous pedicle screw placement with the O-arm Multidimensional Intraoperative Imaging System is a safe and effective technique and provided improved overall accuracy and reduced operative time compared with conventional fluoroscopic techniques.


2015 ◽  
Vol 28 (9) ◽  
pp. E522-E527 ◽  
Author(s):  
Guangfei Gu ◽  
Hailong Zhang ◽  
Shisheng He ◽  
Xiaobing Cai ◽  
Xin Gu ◽  
...  

2020 ◽  
Author(s):  
Wei-Xing Xu ◽  
wei-guo Ding ◽  
Bin Xu ◽  
Tian-Hong Hu ◽  
Hong-Feng Sheng ◽  
...  

Abstract Background: We studied the characteristics and regularity of appropriate insertion points for percutaneous pedicle screw placement in the lumbar spine using C-arm X-ray fluoroscopy. The purpose of this study was to improve the accuracy of percutaneous pedicle screw placement and reduce the incidence of superior-level facet joint violation. Methods: Six normal spinal specimens were included. Three different methods for placing percutaneous pedicle screws in the lumbar spine were applied, including the Roy-Camille method, Magerl method and Weinstein method. The relationships among the insertion point, pedicle projection and proximal facet joint on C-arm X-ray films were studied. The projection morphology of the vertebral pedicle in different segments of the lumbar spine was observed. The relationship between the outer edge of the pedicle projection and the outer edge of the cranial articular process was also studied. The distance between the insertion point and the facet joint (M1), the distance between the insertion point and outer edge of the cranial articular process (M2), and the distance between the insertion point and the projection center of the pedicle (M) were measured. Results: In this study, we found that the projection shape of the vertebral pedicle differed across segments of the lumbar spine: the shape for L1-L3 was oval, and that for L4-L5 was round. The radiographic study showed that the outer edge of the cranial articular process was located on the lateral side of the outer edge of the pedicle projection and did not overlap with the pedicle projection. M for the Weinstein group was larger than that for the Roy-Camille group (P < 0.05). M1 for the Weinstein group was larger than that for the Roy-Camille and Magerl groups (P < 0.05). M2 for the Roy-Camille group was negative, M2 for the Magerl group was 0, and M2 for the Weinstein group was positive. Conclusion: Under C-arm X-ray fluoroscopy, we were able to accurately identify the characteristics and regularity of the appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine, which was important for improving the accuracy of percutaneous pedicle screw placement and reducing the incidence of superior-level facet joint violation.


2021 ◽  
Author(s):  
Shangju Gao ◽  
Jingchao Wei ◽  
Wenyi Li ◽  
Long Zhang ◽  
Can Cao ◽  
...  

Abstract Background: Robot-assisted pedicle screw placement is usually performed under general anaesthesia to keep the body still. The aim of this study was to compare the accuracy of the robot-assisted technique under regional anaesthesia with conventional fluoroscopy-guided percutaneous pedicle screw placement under general anaesthesia in minimally invasive lumbar fusion surgery.Methods: Patients who underwent robot-assisted percutaneous endoscopic lumbar interbody fusion (PELIF) or fluoroscopy-guided minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) from December 2017 to February 2020 in a single centre were included. Based on the method of percutaneous pedicle screw placement used, patients were divided into the robot-assisted under regional anaesthesia (group RE-RO) and fluoroscopy-guided under general anaesthesia (group GE-FLU) groups. The primary outcome measures were screw accuracy and the incidence of facet joint violation (FJV). Secondary outcome measures included X-ray exposure and intraoperative adverse events.Results: Eighteen patients were included in group RE-RO, and 23 patients were included in group GE-FLU. The percentages of clinically acceptable screws (Gertzbein and Robbins grades A and B) were 94.4% and 91.5%, respectively. There was no significant difference in the percentages of clinically acceptable screws (p=0.44) or overall Gertzbein and Robbins screw accuracy grades (p=0.35). Only the top screws were included in the analysis of FJVs. The percentages of FJV (Babu grades 1, 2 and 3) were 5.6% and 28.3%, respectively. This difference was statistically significant (p=0.01). Overall, the FJV grades in group RE-RO were significantly better than those in group GE-FLU (p=0.009). The mean fluoroscopy time for each screw in group RE-RO was significantly shorter than that in group GE-FLU (group RE-RO, 5.4±1.9 seconds, group GE-FLU, 6.8±2.0 seconds; P=0.03). The intraoperative adverse events included 1 case of registration failure and 1 case of guide-wire dislodgment in group RE-RO as well as 2 cases of screw misplacement in group GE-FLU. No complications related to anaesthesia were observed.Conclusion: Robot-assisted pedicle screw placement under regional anaesthesia can be performed effectively and safely. The accuracy is comparable to the conventional technique. Moreover, this technique has the advantage of fewer FJVs and a lower radiation time.


Neurosurgery ◽  
2013 ◽  
Vol 73 (suppl_1) ◽  
pp. S107-S110
Author(s):  
Rohan Chitale ◽  
George M. Ghobrial ◽  
Darlene Lobel ◽  
James Harrop

Abstract BACKGROUND: The learning and development of technical skills are paramount for neurosurgical trainees. External influences and a need for maximizing efficiency and proficiency have encouraged advancements in simulator-based learning models. OBJECTIVE: To confirm the importance of establishing an educational curriculum for teaching minimally invasive techniques of pedicle screw placement using a computer-enhanced physical model of percutaneous pedicle screw placement with simultaneous didactic and technical components. METHODS: A 2-hour educational curriculum was created to educate neurosurgical residents on anatomy, pathophysiology, and technical aspects associated with image-guided pedicle screw placement. Predidactic and postdidactic practical and written scores were analyzed and compared. Scores were calculated for each participant on the basis of the optimal pedicle screw starting point and trajectory for both fluoroscopy and computed tomographic navigation. RESULTS: Eight trainees participated in this module. Average mean scores on the written didactic test improved from 78% to 100%. The technical component scores for fluoroscopic guidance improved from 58.8 to 52.9. Technical score for computed tomography—navigated guidance also improved from 28.3 to 26.6. CONCLUSION: Didactic and technical quantitative scores with a simulator-based educational curriculum improved objectively measured resident performance. A minimally invasive spine simulation model and curriculum may serve a valuable function in the education of neurosurgical residents and outcomes for patients.


2009 ◽  
pp. 149-158
Author(s):  
Hormoz Sheikh ◽  
Ramiro A. Perez de la Torre ◽  
Oksana Didyuk ◽  
Vickram Tejwani ◽  
Mick J. Perez-Cruet

2013 ◽  
Vol 18 (4) ◽  
pp. 356-361 ◽  
Author(s):  
Darryl Lau ◽  
Samuel W. Terman ◽  
Rakesh Patel ◽  
Frank La Marca ◽  
Paul Park

Object A reported risk factor for adjacent-segment disease is injury to the superior facet joint from pedicle screw placement. Given that the facet joint is not typically visualized during percutaneous pedicle screw insertion, there is a concern for increased facet violation (FV) in minimally invasive fusion procedures. The purpose of this study was to analyze and compare the incidence of FV among patients undergoing minimally invasive transforaminal lumbar interbody fusion (MITLIF) and open transforaminal lumbar interbody fusion (TLIF). The impact of O-arm navigation compared with traditional fluoroscopy on FV in MITLIF is also assessed, as are risk factors for FV. Methods The authors identified a consecutive population of patients who underwent MITLIF with percutaneous pedicle screw placement, as well as a matched cohort of patients who underwent open TLIF. Postoperative CT imaging was assessed to determine intraarticular FV due to pedicle screw placement. Patients were stratified into minimally invasive and open TLIF groups. Within the MITLIF group, the authors performed a subanalysis of image guidance methods used in cases of FV. Two-tailed Student t-test, ANOVA, chi-square testing, and logistic regression were used for statistical analysis. Results A total of 282 patients were identified, with a total of 564 superior pedicle screw placements. The MITLIF group consisted of 142 patients with 284 screw insertions. The open TLIF group consisted of 140 patients with 280 screw insertions. Overall, 21 (7.4%) of 282 patients experienced FV. A total of 21 screws violated a facet joint for a screw-based FV rate of 3.7% (21 of 564 screws). There were no significant differences between the MITLIF and open TLIF groups in the percentage of patients with FV (6.3% vs 8.6%) and or the percentage of screws with FV (3.2% vs 4.3%) (p = 0.475 and p = 0.484, respectively). Further stratifying the MI group into O-arm navigation and fluoroscopic guidance subgroups, the patient-based rates of FV were 10.8% (4 of 37 patients) and 4.8% (5 of 105 patients), respectively, and the screw-based rates of FV were 5.4% (4 of 74 screws) and 2.4% (5 of 210 screws), respectively. There was no significant difference between the subgroups with respect to patient-based or screw-based FV rates (p = 0.375 and p = 0.442, respectively). The O-arm group had a significantly higher body mass index (BMI) (p = 0.021). BMI greater than 29.9 was independently associated with higher FV (OR 2.36, 95% CI 1.65–8.53, p = 0.039). Conclusions The findings suggest that minimally invasive pedicle screw placement is not associated with higher rates of FV. Overall violation rates were similar in MITLIF and open TLIF. Higher BMI, however, was a risk factor for increased FV. The use of O-arm fluoroscopy with computer-assisted guidance did not significantly decrease the rate of FV.


Sign in / Sign up

Export Citation Format

Share Document