pedicle screw
Recently Published Documents


TOTAL DOCUMENTS

3363
(FIVE YEARS 957)

H-INDEX

94
(FIVE YEARS 11)

2022 ◽  
Vol 19 (1) ◽  
pp. 13-17
Author(s):  
Sandeep Gurung ◽  
Gopal Sagar DC

Introduction: Surgical treatment of thoracolumbar fracture without neurological damage has resulted in better clinical and radiological outcome than conservative treatment. Traditional open approach is associated with extensive paravertebral muscle damage and postoperative morbidity so percutaneous pedicle screw fixation is highly valuable alternatives. Aims: to evaluate the efficacy and outcome of percutaneous pedicle screw fixation in the treatment of traumatic thoracolumbar fracture without neurological deficit. Methods: This study was conducted in Nepalgunj Medical College, Nepalgunj in a time span of one year; total of 40 patients were included and treated with percutaneous pedicle screw fixation and followed up for 6months. They were evaluated clinically and radiologically. Results: 40 patients with thoracolumbar fractures were managed with percutaneous pedicle screw fixation with a mean operative time of 77.30 min and intraoperative blood loss was 88.38ml. There was significant improvement in cobb’s angle (mean difference 13.92 degree), vertebral body height loss (mean difference 37.7%) and visual analogue scale (mean difference 3.55) postoperatively. These improvements remained statically significant at 6months follow up. Conclusion: Percutaneous pedicle screw fixation is safe, valid and effective treatment of thoracolumbar fracture without neurological deficit.


2022 ◽  
Vol 11 (2) ◽  
pp. 419
Author(s):  
Takashi Yurube ◽  
Yutaro Kanda ◽  
Masaaki Ito ◽  
Yoshiki Takeoka ◽  
Teppei Suzuki ◽  
...  

An electrical conductivity-measuring device (ECD) has recently been developed to support pedicle screw placement. However, no evidence exists regarding its efficacy for syndromic/neuromuscular scoliosis with extremely difficult screwing. We retrospectively reviewed 2010–2016 medical records of 21 consecutive syndromic/neuromuscular scoliosis patients undergoing free-hand segmental fixation surgery at our institution and compared the pedicle screw insertion accuracy and safety between 10 with a conventional non-ECD probe (2010–2013) and 11 with an ECD probe (2014–2016). We analyzed preoperative pedicle shape and postoperative screw placement in computed tomography. There were no significant differences between ECD and non-ECD groups in demographic, clinical, and treatment characteristics including scoliosis severity and pedicle diameter. The abandonment rate due to liquorrhea or perforation was lower in ECD (12.3%) than in non-ECD (26.7%) (p < 0.01). Acceptable insertion without perforation or <2-mm lateral/cranial position was more frequent in ECD (67.1%) than in non-ECD (56.9%) (p = 0.02). Critical ≥5-mm medial/caudal malposition was not seen in ECD (0.0%) but in non-ECD (2.4%) (p = 0.02). The perforation distance was shorter in ECD (2.2 ± 1.1 mm) than in non-ECD (2.6 ± 1.7 mm) (p = 0.01). Results involve small sample size, selection, performance, and learning curve biases; nevertheless, ECD could be useful for more accurate and safer pedicle screw placement in severe syndromic/neuromuscular scoliosis.


2022 ◽  
Vol 11 (2) ◽  
pp. 396
Author(s):  
Ji-Won Kwon ◽  
Edward O. Arreza ◽  
Anthony A. Suguitan ◽  
Soo-Bin Lee ◽  
Sahyun Sung ◽  
...  

This study describes a new and safe freehand cervical pedicle screw insertion technique using preoperative computed tomography (CT) morphometric measurements as a guide and a medial pedicle pivot point (MPPP) during the procedure. This study included 271 pedicles at 216 cervical spine levels (mean: 4.75 pedicles per patient). A pedicle diameter (PD) ≥ 3.5 mm was the cut-off for pedicle screw fixation. The presence and grade of perforation were detected using postoperative CT scans, where perforations were graded as follows: 0, no perforation; 1, perforation < 0.875 mm; 2, perforation 0.875–1.75 mm; and 3, perforation > 1.75 mm. The surgical technique involved the use of an MPPP, which was the point at which the lines representing the depth of the lateral mass and total length of the pedicle intersected, deep in the lateral mass. The overall success rate was 96.3% (261/271, Grade 0 or 1 perforations). In total, 54 perforations occurred, among which 44 (81.5%) were Grade 1 and 10 (18.5%) were Grade 2. The most common perforation direction was medial (39/54, 72.2%). The freehand technique for cervical pedicle screw fixation using the MPPP may allow for a safe and accurate procedure in patients with a PD ≥3.5 mm.


2022 ◽  
Vol 15 (1) ◽  
Author(s):  
Rahadyan Magetsari ◽  
Tedjo Rukmoyo ◽  
Marda Ade Saputra ◽  
Yudha Mathan Sakti

Abstract Objective This research aimed to developing customized pedicle screw based on Indonesian vertebral anatomy and compare the insertion time, pull-out strength, and screw-media interface area of different screw design. We have developed 3 different types of pedicle screws (v-thread cylinder-core, square-thread cylinder-core and square-thread conical-core). The thread diameter was calculated from pedicle width of Indonesian population (6 mm). We used commercially available pedicle screw as control group (6.2 mm). Result The insertion time were significantly difference between v-thread cylinder-core pedicle screw (22.94 s) with commercially available pedicle screw (15.86 s) (p < 0.05). The pull-out strength was significantly difference between commercially available pedicle screw (408.60 N) with square-thread conical pedicle screw (836.60 N) (p < 0.05). The square-thread conical-core group have the highest interface area (1486.21 mm2). The data comparison showed that the square-thread conical-core customized pedicle screw group has comparable insertion time and has better pull-out strength than commercially available pedicle screw.


Spine ◽  
2022 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Wesley M. Durand ◽  
Kevin J. DiSilvestro ◽  
Han Jo Kim ◽  
David K. Hamilton ◽  
Renaud Lafage ◽  
...  

2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Peng Tao Wang ◽  
Jia Nan Zhang ◽  
Tuan Jiang Liu ◽  
Jun Song Yang ◽  
Ding Jun Hao

Abstract Background To analyze the risk factors for pedicle screw invasion of the proximal facet joint after lumbar surgery. Methods From January 2019 to January 2021, 1794 patients with lumbar degenerative disease, such as lumbar disc herniation, lumbar spinal stenosis and lumbar spondylolisthesis, were treated at our hospital. In all, 1221 cases were included. General data (sex, age, BMI), bone mineral density, proximal facet joint angle, degenerative lumbar spondylolisthesis, isthmic lumbar spondylolisthesis and fixed segment in the two groups were recorded. After the operation, vertebral CT of the corresponding surgical segments was performed for three-dimensional reconstruction and evaluation of whether the vertebral arch root screw interfered with the proximal facet joint. The included cases were divided into an invasion group and a noninvasion group. Univariate analysis was used to screen the risk factors for pedicle screw invasion of the proximal facet joint after lumbar surgery, and the selected risk factors were included in the logistic model for multivariate analysis. Results The single-factor analysis showed a significant difference in age, BMI, proximal facet joint angle, degenerative lumbar spondylolisthesis, and fixed segment (P < 0.1). Multifactor analysis of the logistic model showed a significant difference for age ≥ 50 years (P < 0.001, OR = 2.291), BMI > 28 kg/m2 (P < 0.001, OR = 2.548), degenerative lumbar spondylolisthesis (P < 0.001, OR = 2.187), gorge cleft lumbar relaxation (P < 0.001, OR = 2.410), proximal facet joint angle (35 ~ 45°: P < 0.001, OR = 3.151; > 45°: P < 0.001, OR = 3.578), and fixed segment (lower lumbar spine: P < 0.001, OR = 2.912). Conclusion Age (≥ 50 years old), BMI (> 28 kg/m2), proximal facet joint angle (35 ~ 45°, > 45°), degenerative lumbar spondylolisthesis, isthmic lumbar spondylolisthesis and fixed segment (lower lumbar spine) are independent risk factors for pedicle screw invasion of the proximal facet joint after lumbar surgery. Compared with degenerative lumbar spondylolisthesis, facet joint intrusion is more likely in isthmic lumbar spondylolisthesis.


2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Peng Tao Wang ◽  
Jia Nan Zhang ◽  
Tuan Jiang Liu ◽  
Jun Song Yang ◽  
Ding Jun Hao

Abstract Background Pedicle screw invasion of the proximal articular process will cause local articular process degeneration and acceleration, which is an important factor affecting adjacent segment degeneration. Although lumbar spondylolisthesis is a risk factor for screw invasion of the proximal joint, there is no clear conclusion regarding the two different types of spondylolisthesis. Therefore, the purpose of this study was to explore the influence of pedicle screw placement on proximal facet invasion in the treatment of degenerative spondylolisthesis and isthmic spondylolisthesis. Methods In total, 468 cases of lumbar spondylolisthesis treated by decompression and fusion in our hospital from January 2017 to January 2020 were included in this retrospective study. Among them, 238 cases were degenerative spondylolisthesis (group A), and 230 cases were isthmic spondylolisthesis (group B). Sex, age, body mass index, bone mineral density, preoperative visual analog scale (VAS) and Oswestry Disability Index (ODI) scores, postoperative VAS and ODI scores at 1 month and 3 months, and angle of the proximal facet joint at the last follow-up were recorded and compared between the two groups. The degree of pedicle screw invasion of the proximal facet joint was graded and compared by the SEO grading method. Results There were no significant differences in sex, age, body mass index, bone mineral density, preoperative VAS and ODI scores, or proximal facet joint angle between the two groups (P > 0.05). There was no significant difference in VAS and ODI scores between the two groups at 1 month and 3 months after the operation (P > 0.05). The VAS score of group A at the last follow-up was 1 (1,2). The VAS score of group B at the last follow-up was 3 (1,3). The ODI score of group A at the last follow-up was 6(4,26). The ODI score of group B at the last follow-up was 15(8,36). The VAS and ODI scores of the two groups at the last follow-up were significantly different (P < 0.05). According to the SEO grading method, the invasion of the proximal articular process by pedicle screw placement in group A involved 320 cases in grade 0, 128 cases in grade I and 28 cases in grade II. In group B, there were 116 cases in grade 0, 248 cases in grade I and 96 cases in grade II, with a significant difference (P < 0.01). Conclusion In summary, a certain number of cases involving screws invading the proximal facet joint occurred in the two different types of lumbar spondylolisthesis, but the number in the isthmic spondylolisthesis group was significantly higher than that in the degenerative spondylolisthesis group, which caused more trauma to the proximal facet joint and significantly affected the patient prognosis.


2022 ◽  
Vol 52 (1) ◽  
pp. E8

OBJECTIVE Pedicle screw insertion for stabilization after lumbar fusion surgery is commonly performed by spine surgeons. With the advent of navigation technology, the accuracy of pedicle screw insertion has increased. Robotic guidance has revolutionized the placement of pedicle screws with 2 distinct radiographic registration methods, the scan-and-plan method and CT-to-fluoroscopy method. In this study, the authors aimed to compare the accuracy and safety of these methods. METHODS A retrospective chart review was conducted at 2 centers to obtain operative data for consecutive patients who underwent robot-assisted lumbar pedicle screw placement. The newest robotic platform (Mazor X Robotic System) was used in all cases. One center used the scan-and-plan registration method, and the other used CT-to-fluoroscopy for registration. Screw accuracy was determined by applying the Gertzbein-Robbins scale. Fluoroscopic exposure times were collected from radiology reports. RESULTS Overall, 268 patients underwent pedicle screw insertion, 126 patients with scan-and-plan registration and 142 with CT-to-fluoroscopy registration. In the scan-and-plan cohort, 450 screws were inserted across 266 spinal levels (mean 1.7 ± 1.1 screws/level), with 446 (99.1%) screws classified as Gertzbein-Robbins grade A (within the pedicle) and 4 (0.9%) as grade B (< 2-mm deviation). In the CT-to-fluoroscopy cohort, 574 screws were inserted across 280 lumbar spinal levels (mean 2.05 ± 1.7 screws/ level), with 563 (98.1%) grade A screws and 11 (1.9%) grade B (p = 0.17). The scan-and-plan cohort had nonsignificantly less fluoroscopic exposure per screw than the CT-to-fluoroscopy cohort (12 ± 13 seconds vs 11.1 ± 7 seconds, p = 0.3). CONCLUSIONS Both scan-and-plan registration and CT-to-fluoroscopy registration methods were safe, accurate, and had similar fluoroscopy time exposure overall.


2022 ◽  
Vol 52 (1) ◽  
pp. E11

OBJECTIVE The application of robots in the field of pedicle screw placement has achieved great success. However, decompressive laminectomy, a step that is just as critical as pedicle screw placement, does not have a mature robot-assisted system. To address this lack, the authors designed a collaborative spine robot system to assist with laminectomy. In this study, they aimed to investigate the reliability of this novel collaborative spinal robot system and compare it with manual laminectomy (ML). METHODS Thirty in vitro porcine lumbar vertebral specimens were obtained as experimental bone specimens. Robot-assisted laminectomy (RAL) was performed on the left side of the lamina (n = 30) and ML was performed on the right side (n = 30). The time required for laminectomy on one side, whether the lamina was penetrated, and the remaining thickness of the lamina were compared between the two groups. RESULTS The time required for laminectomy on one side was longer in the RAL group than in the ML group (median 326 seconds [IQR 133 seconds] vs 108.5 seconds [IQR 43 seconds], p < 0.001). In the RAL group, complete lamina penetration occurred twice (6.7%), while in the ML group, it occurred 9 times (30%); the difference was statistically significant (p = 0.045). There was no statistically significant difference in the remaining lamina thickness between the two groups (median 1.035 mm [IQR 0.419 mm] vs 1.084 mm [IQR 0.383 mm], p = 0.842). CONCLUSIONS The results of this study confirm the safety of this novel spinal robot system for laminectomy. However, its efficiency requires further improvement.


Sign in / Sign up

Export Citation Format

Share Document