Endovascular Treatment of Aneurysms Using Flow-Diversion Embolization: 2-Dimensional Operative Video

2021 ◽  
Author(s):  
Daniel D Cavalcanti ◽  
Peter Kim Nelson ◽  
Eytan Raz ◽  
Maksim Shapiro ◽  
Erez Nossek ◽  
...  

Abstract Initially developed for large and giant wide-necked aneurysms of the internal carotid artery, flow diverter devices are now used in almost every location safely and with effectiveness.1-5 This video demonstrates a unique case of a giant aneurysm of the right petrous internal carotid artery in a 20-yr-old patient. This is an extremely rare location, and most of patients are asymptomatic.3-6 Signs of compression of the seventh and eight cranial nerves can be present and even Horner syndrome and lower cranial nerves neuropathies. Nevertheless, rupture can lead to epistaxis and otorrhagia, and ultimately to hemorrhagic shock. The patient in the current report was otherwise healthy but presented with lightheadedness and dizziness for 10 d. The patient consented to the procedure. There was no history of major trauma or head and neck infection. A transradial endovascular flow diversion embolization of a giant aneurysm of the petrous internal carotid artery is herein demonstrated in a stepwise manner. A triaxial system was used to deploy 3 overlapping devices. Concepts of J-wire technique, multiple coverage,1 and the so-called weld technique are emphasized. The role of adjunctive coiling and main reasons for failure are also discussed.7,8 Brief cases of flow diversion embolization of aneurysms of different morphologies at different locations are used to highlight the importance of assessing vessel wall apposition and follow-up imaging.

2020 ◽  
Vol 13 (6) ◽  
pp. e015581
Author(s):  
Mark Alexander MacLean ◽  
Thien J Huynh ◽  
Matthias Helge Schmidt ◽  
Vitor M Pereira ◽  
Adrienne Weeks

We report the case of a patient with subarachnoid hemorrhage and three aneurysms arising from the posterior communicating artery (Pcomm)-P1 complex, treated with endovascular coiling and competitive flow diversion. The largest and likely ruptured Pcomm aneurysm was treated with traditional coiling. Two smaller potentially ruptured aneurysms arose from the distal right posterior cerebral artery (PCA) P1 segment. After a failed attempt to treat with conventional flow diversion across the PCA-P1 segment, the P1 aneurysms were successfully treated with competitive flow diversion distal to the PCA-P1 segment from Pcomm to the P2 segment. Over 12 months, competitive flow diversion redirected flow to the right PCA territory via the internal carotid artery-Pcomm-P2, reducing the size of the PCA-P1 segment and obliterating the P1 aneurysms. Competitive flow diversion treatment should be considered for aneurysms occurring at the circle of Willis when traditional methods are not feasible. Herein, we introduce a novel classification for competitive flow diversion treatment.


2015 ◽  
Vol 8 (3) ◽  
pp. 279-286 ◽  
Author(s):  
Geoffrey P Colby ◽  
Li-Mei Lin ◽  
Justin M Caplan ◽  
Bowen Jiang ◽  
Barbara Michniewicz ◽  
...  

BackgroundFlow diversion is an important tool for treatment of cerebral aneurysms, particularly large and giant aneurysms. The Surpass flow diverter is a new system under evaluation in the USA.ObjectiveTo report our initial experience of 20 cases with the Surpass flow diverter to demonstrate its basic properties, the required triaxial delivery platform, and the methodologies used to deploy it during treatment of large internal carotid artery (ICA) aneurysmsMethodsTwenty patients with ICA aneurysms ≥10 mm with ≥4 mm neck treated as part of the Surpass IntraCranial Aneurysm Embolization System Pivotal Trial (the SCENT trial; Stryker) were included. Details of patient demographics, aneurysm characteristics, and technical procedures were collected.ResultsTwenty patients (mean age 63.3±1.3 years; range 51–72) with 20 unruptured aneurysms (mean size 13.4±0.9 mm; range 10–21 mm) were treated. For proximal access, 60% of cases had aortic arch ≥grade II, 55% had significant cervical ICA tortuosity, and 60% had cavernous ICA ≥grade II. The Surpass device was implanted in 19/20 (95%) cases. Of 19 cases, a single device was used in 18 cases (95%) and 2 devices in only 1 case (5%). Balloon angioplasty was performed in 8/19 cases (42%). Complete aneurysm neck coverage and adequate vessel wall apposition was obtained in all 19 cases.ConclusionsSurpass is a next-generation flow diverter with unique device-specific and delivery-specific features compared with clinically available endoluminal flow diverters. Our initial experience demonstrates a favorable technical profile in treatment of large and giant ICA aneurysms.Trial registration numberNCT01716117.


2018 ◽  
Vol 23 (3) ◽  
pp. 246-250
Author(s):  
Guilherme Cabral De Andrade ◽  
Helvércio F. Polsaque Alves ◽  
Roberto Parente Júnior ◽  
Cármine P. Salvarani ◽  
Walter M. Clímaco ◽  
...  

Aneurysmal dissection of the internal carotid artery in the cavernous segment is an uncommon lesion, as well as the association with subarachnoid hemorrhage. Its description is related to direct or indirect trauma of the neck region. We report on a 26 year-old male patient who presented in the imediate postoperative after an orthognathic surgery with paralysis the right ocular cranial nerves (IIIº °, IVº ° and VIº°) with ophthalmoplegia, without chemosis or proptosis and with subarachnoid hemorrhage in the cranial tomography. Angiography disclosed a dissecting aneurysm of the right internal carotid artery in the cavernous segment, presenting with rebleeding during his evolution. The therapeutic option was arterial embolization with platinum microcoils. After extensive literature review, endovascular treatment was suggested. 


2020 ◽  
Vol 18 (3) ◽  
pp. 563-565
Author(s):  
Subash Phuyal ◽  
Pooja Agrawal ◽  
Ritesh Lamsal ◽  
Nirmal Prasad Neupane ◽  
Gopal Sedain

Giant intracranial aneurysms are defined as aneurysms that measure over 25 mm in the greatest dimension. They are rare vascular lesions that preferentially involve regions with high-velocity blood flow, such as the cavernous and supraclinoid segments of the internal carotid artery, the middle cerebral artery, the vertebrobasilar region, and the basilar apex. The treatment of giant aneurysms is challenging and associated with high rates of morbidity and mortality. Flow-diverter devices have revolutionized their treatment in recent times. We report the successful management of two patients with giant cavernous internal carotid artery aneurysms using flow-diverter devices for the first time in Nepal. Keywords: Endovascular; flow-diverter devices; giant aneurysm


2016 ◽  
Vol 50 (4) ◽  
pp. 378-384 ◽  
Author(s):  
Marko Jevsek ◽  
Charbel Mounayer ◽  
Tomaz Seruga

Abstract Background Intra-arterial treatment of aneurysms by redirecting blood flow is a newer method. The redirection is based on a significantly more densely braided wire stent. The stent wall keeps the blood in the lumen of the stent and slows down the turbulent flow in the aneurysms. Stagnation of blood in the aneurysm sac leads to the formation of thrombus and subsequent exclusion of the aneurysm from the circulation. The aim of the study was to evaluate flow diverter device Pipeline for broad neck and giant aneurysm treatment. Methods Fifteen patients with discovered aneurysm of the internal carotid artery were treated between November 2010 and February 2014. The majority of aneurysms of the internal carotid artery were located intradural at the ophthalmic part of the artery. The patients were treated using a flow diverter device Pipeline, which was placed over the aneurysm neck. Treatment success was assessed clinically and angiographically using O’Kelly Marotta scale. Results Control angiography immediately after the release of the stent showed stagnation of the blood flow in the aneurysm sac. In none of the patients procedural and periprocedural complications were observed. 6 months after the procedure, control CT or MR angiography showed in almost all cases exclusion of the aneurysm from the circulation and normal blood flow in the treated artery. Neurological status six months after the procedure was normal in all patients. Conclusions Treatment of aneurysms with flow diverter Pipeline device is a safe and significantly less time consuming method in comparison with standard techniques. This new method is a promising approach in treatment of broad neck aneurysms.


2007 ◽  
Vol 13 (3) ◽  
pp. 281-285 ◽  
Author(s):  
H. Nakayama ◽  
S. Iwabuchi ◽  
M. Hayashi ◽  
T. Yokouchi ◽  
H. Terada ◽  
...  

We describe a case of giant cervical internal carotid aneurysm successfully treated by endovascular trapping. A 57-year-old woman with a history of maxillary contusion seven years before presented with pharyngeal discomfort during swallowing. MRI revealed a 4 cm mass in the right parapharyngeal space. A common carotid angiogram revealed a giant aneurysm with a wide neck originating from the cervical internal carotid artery; kinking of the internal carotid artery was noted at a point distal to the carotid bifurcation. Analysis of cerebral blood flow by SPECT during a balloon occlusion test showed no hypoperfusion areas, and the patient underwent endovascular trapping. There were no neurological or other complications after the procedure. A follow-up MRI revealed complete thrombosis of the aneurysm. Our results show that endovascular trapping for pseudoaneurysm of the cervical internal carotid artery can be a reliable and effective treatment in patients who tolerate a balloon occlusion test.


Neurosurgery ◽  
2019 ◽  
Vol 86 (Supplement_1) ◽  
pp. S55-S63
Author(s):  
Kunal Vakharia ◽  
Stephan A Munich ◽  
Muhammad Waqas ◽  
Elad I Levy ◽  
Adnan H Siddiqui

Abstract Several studies have shown the efficacy and feasibility of flow diversion for the endovascular treatment of wide-necked and otherwise anatomically challenging intracranial aneurysms (IA). Technological advances have led to successful long-term occlusion rates and a safety profile for flow-diverter stents that parallels other endovascular and open surgical options for these lesions. With growing indications for use of the Pipeline Embolization Device (PED, Medtronic, Dublin, Ireland) to include IAs up to the internal carotid artery (ICA) terminus, understanding the nuances of this technology is increasingly relevant. Furthermore, there is a growing body of literature on the use of flow diversion to treat distal (up to A2, M2, and P2), ruptured, and posterior circulation aneurysms, although these applications are “off-label” at present. In this manuscript, we discuss the expanding role of flow diversion in the ICA and compare this technique with other endovascular options for the treatment of ICA IAs. We also discuss technical nuances of the deployment of flow diverters for the treatment of challenging lesions and in difficult and tortuous anatomy.


2020 ◽  
Vol 12 (9) ◽  
pp. e7-e7
Author(s):  
Mark Alexander MacLean ◽  
Thien J Huynh ◽  
Matthias Helge Schmidt ◽  
Vitor M Pereira ◽  
Adrienne Weeks

We report the case of a patient with subarachnoid hemorrhage and three aneurysms arising from the posterior communicating artery (Pcomm)-P1 complex, treated with endovascular coiling and competitive flow diversion. The largest and likely ruptured Pcomm aneurysm was treated with traditional coiling. Two smaller potentially ruptured aneurysms arose from the distal right posterior cerebral artery (PCA) P1 segment. After a failed attempt to treat with conventional flow diversion across the PCA-P1 segment, the P1 aneurysms were successfully treated with competitive flow diversion distal to the PCA-P1 segment from Pcomm to the P2 segment. Over 12 months, competitive flow diversion redirected flow to the right PCA territory via the internal carotid artery-Pcomm-P2, reducing the size of the PCA-P1 segment and obliterating the P1 aneurysms. Competitive flow diversion treatment should be considered for aneurysms occurring at the circle of Willis when traditional methods are not feasible. Herein, we introduce a novel classification for competitive flow diversion treatment.