USING RESPIRATORY EXCHANGE RATIO TO IDENTIFY ANAEROBIC THRESHOLD: A NEW METHOD 800

1996 ◽  
Vol 28 (Supplement) ◽  
pp. 134
Author(s):  
A. K. Lish ◽  
P. Watts
2017 ◽  
Vol 23 (10) ◽  
pp. S59
Author(s):  
Naoya Kakutani ◽  
Arata Fukushima ◽  
Takashi Yokota ◽  
Takashi Katayama ◽  
Ryosuke Shirakawa ◽  
...  

Author(s):  
Fernando Diefenthaeler ◽  
Raphael Luiz Sakugawa ◽  
Rodolfo André Dellagrana ◽  
Bruno Follmer ◽  
Elisa Cristina Lemos ◽  
...  

DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n1p108 Several studies showed that respiratory exchange ratio (RER) have been used as an alternative to evaluate the aerobic capacity in a single incremental test. However, few studies have investigated trained runners. The aim of this study was to verify if the respiratory exchange ratio (RER) could be used as an alternative criterion for estimating anaerobic threshold (AT) in long-distance runners. Nineteen male long-distance runners volunteered to participate in the study. An incremental treadmill test was performed with initial speed of 10 km·h-1 with increments of 1 km·h-1 every 1 min until voluntary exhaustion. The variables measured were oxygen uptake (VO2), first and second ventilatory thresholds (VT1 and VT2, respectively), intensity corresponding to RER level of1.0 (iRER1.0), peak velocity (PV), heart rate (HR), and rate of perceived exertion (RPE). One-way repeated measure analysis variance was used, following Bonferroni post hoc test. Agreement between parameters was evaluated by Pearson correlation and dispersion error. There were no significant differences between iRER1.0 and VT2 parameters. The correlations were significant between iRER1.0 and VT2 parameters for absolute and relative VO2, speed, and HR (r=0.95; r=0.60; r=0.72; r=0.81, respectively). A small mean error (-0.2 km·h-1) was observed between iRER1.0 and VT2. However, it was also observed an overestimation trend for high speeds. In conclusion, iRER1.0 can be used as an alternative method to detect AT in long distance runners. However, its use is limited in runners with high aerobic capacity.


Author(s):  
C. C. Clawson ◽  
L. W. Anderson ◽  
R. A. Good

Investigations which require electron microscope examination of a few specific areas of non-homogeneous tissues make random sampling of small blocks an inefficient and unrewarding procedure. Therefore, several investigators have devised methods which allow obtaining sample blocks for electron microscopy from region of tissue previously identified by light microscopy of present here techniques which make possible: 1) sampling tissue for electron microscopy from selected areas previously identified by light microscopy of relatively large pieces of tissue; 2) dehydration and embedding large numbers of individually identified blocks while keeping each one separate; 3) a new method of maintaining specific orientation of blocks during embedding; 4) special light microscopic staining or fluorescent procedures and electron microscopy on immediately adjacent small areas of tissue.


1960 ◽  
Vol 23 ◽  
pp. 227-232 ◽  
Author(s):  
P WEST ◽  
G LYLES
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document