Ratings of Perceived Exertion, Heart Rate, and Treadmill Speed in the Prediction of Maximal Oxygen Uptake During Submaximal Treadmill Exercise

1985 ◽  
Vol 5 (11) ◽  
pp. 540
Author(s):  
Jack H. Wilmore ◽  
Fred B. Roby ◽  
Philip R. Stanforth ◽  
Michael J. Buono ◽  
Stefan H. Constable ◽  
...  
1996 ◽  
Vol 82 (2) ◽  
pp. 419-424 ◽  
Author(s):  
Antonios K. Travlos ◽  
Daniel Q. Marisi

This study was conducted to investigate the influence of fitness level and gradually increased amounts of exercise on individuals' ratings of perceived exertion (RPE). 20 men served as paid subjects. They were divided into groups of high (>56 ml/kg/min.) and low fitness (<46 ml/kg/min.) according to their maximal oxygen uptake (VO2 max). Participants were required to pedal on a cycle ergometer at a progressively increased workload (every 10 min.) corresponding to 40, 50, 60, 70, and 80% of individual VO2 max values. Heart rates, RPE, and core temperatures were recorded every 5th minute after the initiation of exercising at a specific workload. Analysis indicated that, when controlling for VO2 max values, elevations of heart rate and core temperature were not affected by fitness. However, highly fit individuals perceived themselves under less exertion than did the group low in fitness. Correlations showed that, taking into consideration fitness, there is a stronger relationship between RPE and heart rate and RPE and core temperature for the highly fit individuals than for the less fit.


1986 ◽  
Vol 14 (3) ◽  
pp. 133-143 ◽  
Author(s):  
Jack H. Wilmore ◽  
Fred B. Roby ◽  
Philip R. Stanforth ◽  
Michael J. Buono ◽  
Stefan H. Constable ◽  
...  

2009 ◽  
Vol 23 (4) ◽  
pp. 1292-1299 ◽  
Author(s):  
Michelle Mielke ◽  
Terry J Housh ◽  
C Russell Hendrix ◽  
Clayton L Camic ◽  
Jorge M Zuniga ◽  
...  

1994 ◽  
Vol 78 (3_suppl) ◽  
pp. 1335-1344 ◽  
Author(s):  
Christopher C. Dunbar ◽  
Carole Goris ◽  
Donald W. Michielli ◽  
Michael I. Kalinski

The accuracy of regularing exercise intensity by Ratings of Perceived Exertion (RPE) was examined. Subjects underwent 4 production trials, 2 on a treadmill (PIA, P1B) and 2 on a cycle ergometer (P2A, P2B). 9 untrained subjects used only their perceptions of effort to regulate exercise intensity. Target intensity was the RPE equivalent to 60% VO2mx. Exercise intensity (VO2) during P1A, P1B, and P2A did not differ from the target, but during P2B was lower than target. During P1A and P1B heart rate did not differ from the target but was lower than target during P2A and P2B. RPE seems a valid means of regulating exercise intensity during repeated bouts of treadmill exercise at 60% VO2max; however, exercise intensity during repeated bouts on the cycle ergometer may be lower than target.


Sign in / Sign up

Export Citation Format

Share Document