oxygen uptake
Recently Published Documents


TOTAL DOCUMENTS

6100
(FIVE YEARS 704)

H-INDEX

111
(FIVE YEARS 8)

Biology ◽  
2022 ◽  
Vol 11 (1) ◽  
pp. 144
Author(s):  
Hun-Young Park ◽  
Jeong-Weon Kim ◽  
Sang-Seok Nam

We compared the effects of metabolic, cardiac, and hemorheological responses to submaximal exercise under light hypoxia (LH) and moderate hypoxia (MH) versus normoxia (N). Ten healthy men (aged 21.3 ± 1.0 years) completed 30 min submaximal exercise corresponding to 60% maximal oxygen uptake at normoxia on a cycle ergometer under normoxia (760 mmHg), light hypoxia (596 mmHg, simulated 2000 m altitude), and moderate hypoxia (526 mmHg, simulated 3000 m altitude) after a 30 min exposure in the respective environments on different days, in a random order. Metabolic parameters (oxygen saturation (SPO2), minute ventilation, oxygen uptake, carbon dioxide excretion, respiratory exchange ratio, and blood lactate), cardiac function (heart rate (HR), stroke volume, cardiac output, and ejection fraction), and hemorheological properties (erythrocyte deformability and aggregation) were measured at rest and 5, 10, 15, and 30 min after exercise. SPO2 significantly reduced as hypoxia became more severe (MH > LH > N), and blood lactate was significantly higher in the MH than in the LH and N groups. HR significantly increased in the MH and LH groups compared to the N group. There was no significant difference in hemorheological properties, including erythrocyte deformability and aggregation. Thus, submaximal exercise under light/moderate hypoxia induced greater metabolic and cardiac responses but did not affect hemorheological properties.


Author(s):  
Georg Schmücker ◽  
Christof Burgdorf ◽  
Jan-Henrik Blohm ◽  
Mathias Bugno ◽  
Kathrin Meyer ◽  
...  

Abstract Objectives Cardiac output (CO) measurements employing the direct Fick principle represent the gold standard in right-sided heart catheterization (RHC). The current widespread approach in hemodynamic workup however uses the indirect Fick principle with assumed values for oxygen uptake (VO2) leading to incorrect CO values in up to 25% of patients. We have tested a contemporary breath-by-breath gas analyzer that allows precise real-time measurements of VO2 with appropriate time and effort to serve the direct Fick principle. Methods By means of a small and mobile metabolic cart assembled with widely used components of a standard spiroergometer, we performed bedside measurements of individual VO2. In 33 unselected, consecutive patients with various indications for RHC we compared CO values derived from indirect vs. direct Fick calculations. Results In 28 of the 33 patients, VO2 measurements were completed with a plausible dataset within a median of 3.2 (interquartile range 2.8–6.2) min. In nine of the 28 patients, CO values based on measured VO2 values differed by more than 20% from CO calculations based on assumed VO2 values with value deviations scattering over a broad range in both directions (maximally +52% to minimally −46%). Conclusions The bedside measurement of VO2 for gold standard CO determination is technically feasible within a few min and can thus be easily included in any RHC protocol. As modern therapy for numerus indications demand a precise upfront measurement of hemodynamics, our method might help to correctly identify patients for costly therapies.


2022 ◽  
Vol 15 (1) ◽  
Author(s):  
Peter Düking ◽  
Philipp Kunz ◽  
Florian A. Engel ◽  
Helena Mastek ◽  
Billy Sperlich

Abstract Objective Portable gas exchange instruments allow the assessment of peak oxygen uptake (V̇O2peak) but are often bulky, expensive and require wearing a face mask thereby limiting their routine application. A newly developed miniaturized headset (VitaScale, Nuremberg, Germany) may overcome these barriers and allow measuring V̇O2peak without applying a face mask. Here we aimed (i) to disclose the technical setup of a headset incorporating a gas and volume sensor to measure volume flow and expired oxygen concentration and (ii) to assess the concurrent criterion-validity of the headset to measure V̇O2peak in 44 individuals exercising on a stationary cycle ergometer in consideration of the test–retest reliability of the criterion measure. Results The coefficient of variation (CV%) while measuring V̇O2peak during incremental cycling with the headset was 6.8%. The CV% for reliability of the criterion measure was 4.0% for V̇O2peak. Based on the present data, the headset might offer a new technology for V̇O2peak measurement due to its low-cost and mask-free design.


2022 ◽  
pp. 2101821
Author(s):  
Jenna McNeill ◽  
Ariel Chernofsky ◽  
Matthew Nayor ◽  
Farbod N. Rahaghi ◽  
Raul San Jose Estepar ◽  
...  

IntroductionCardiorespiratory fitness is not limited by pulmonary mechanical reasons in the majority of adults. However, the degree to which lung function contributes to exercise response patterns among ostensibly healthy individuals remains unclear.MethodsWe examined 2314 Framingham Heart Study participants who underwent cardiopulmonary exercise testing (CPET) and pulmonary function testing. We investigated the association of FEV1, FVC, FEV1/FVC and DLCO with the primary outcome of peak VO2, along with other CPET parameters using multivariable linear regression. Finally, we investigated the association of total and peripheral pulmonary blood vessel volume with peak VO2.ResultsWe found lower FEV1, FVC and DLCO were associated with lower peak VO2. For example, a one-liter lower FEV1 and FVC were associated with 7.1% (95% CI: 5.1%, 9.1%) and 6.0% (95% CI: 4.3%, 7.7%) lower peak VO2, respectively. By contrast, FEV1/FVC ratio was not associated with peak VO2. Lower lung function was associated with lower oxygen uptake efficiency slope oxygen pulse slope, VO2 at AT, VE at AT and breathing reserve. In addition, lower total and peripheral pulmonary blood vessel volume were associated with a lower peak VO2.ConclusionIn a large, community-based cohort of adults, we found lower FEV1, FVC and DLCO were associated with lower exercise capacity, as well as oxygen uptake efficiency slope and ventilatory efficiency. In addition, lower total and peripheral pulmonary blood vessel volume were associated with lower peak VO2. These findings underscore the importance of lung function and blood vessel volume as contributors to overall exercise capacity.


2022 ◽  
Vol 12 ◽  
Author(s):  
Mara Paneroni ◽  
Simonetta Scalvini ◽  
Ugo Corrà ◽  
Marta Lovagnini ◽  
Roberto Maestri ◽  
...  

Background: In elderly chronic heart failure (HF) patients, activities of daily living (ADLs) require the use of a high proportion of patients’ peak aerobic capacity, heart rate, and ventilation.Objectives: To assess the effects of short-term comprehensive cardiac rehabilitation (CR) on the metabolic requirement of ADLs in elderly patients with chronic HF.Methods: The study population comprised 99 elderly chronic HF patients (mean age 72 ± 5 years, 80% male, 61% ejection fraction <40%, mean NT-proBNP 2,559 ± 4,511 pg/ml) participating in a short-term (mean days 19 ± 7) residential CR program. Before and after CR, participants, while wearing a portable ergospirometer, performed a standardized ADL battery: ADL1 (getting dressed), ADL2 (folding 8 towels), ADL3 (putting away 6 bottles), ADL4 (making a bed), ADL5 (sweeping the floor for 4 min), ADL6 (climbing 1 flight of stairs carrying a 1.5 Kg load), and ADL7 (a standard 6-min walking test).Results: After CR, task-related oxygen uptake did not change in any of the domestic ADLs. Notably, there was a significant decrease in the cumulative time required to perform ADLs (ADL 1–4 and ADL6; from 412 ± 147 to 388 ± 141 s, p = 0.001) and a reduction in maximal heart rate in ADL1 and 3 (p = 0.005 and p = 0.027, respectively). Changes occurred in the 6MWT with an increase in oxygen uptake (p = 0.005) and in the distance covered (p < 0.001) and a significant decrease in the Borg scale of dyspnea (p = 0.004).Conclusion: Elderly patients with chronic heart failure who are engaged in a short-term residential CR program improve the performance of routine ADLs.


Author(s):  
Fang Li ◽  
Chun-Hao Chang ◽  
Chia-An Ho ◽  
Cheng-You Wu ◽  
Hung-Chih Yeh ◽  
...  

The maximal oxygen uptake (VO2max) prediction models established by step tests are often used for evaluating cardiorespiratory fitness (CRF). However, it is unclear which type of stepping frequency sequence is more suitable for the public to assess the CRF. Therefore, the main purpose of this study was to test the effectiveness of two 3-min incremental step-in-place (3MISP) tests (i.e., 3MISP30s and 3MISP60s) with the same total number of steps but different step-frequency sequences in predicting VO2max. In this cross-sectional study, a total of 200 healthy adults in Taiwan completed 3MISP30s and 3MISP60s tests, as well as cardiopulmonary exercise testing. The 3MISP30s and 3MISP60s models were established through multiple stepwise regression analysis by gender, age, percent body fat, and 3MISP-heart rate. The statistical analysis included Pearson’s correlations, the standard errors of estimate, the predicted residual error sum of squares, and the Bland–Altman plot to compare the measured VO2max values and those estimated. The results of the study showed that the exercise intensity of the 3MISP30s test was higher than that of the 3MISP60s test (% heart rate reserve (HRR) during 3MISP30s vs. %HRR during 3MISP60s = 81.00% vs. 76.81%, p < 0.001). Both the 3MISP30s model and the 3MISP60s model explained 64.4% of VO2max, and the standard errors of the estimates were 4.2043 and 4.2090 mL·kg−1·min−1, respectively. The cross-validation results also indicated that the measured VO2max values and those predicted by the 3MISP30s and 3MISP60s models were highly correlated (3MISP30s model: r = 0.804, 3MISP60s model: r = 0.807, both p < 0.001). There was no significant difference between the measured VO2max values and those predicted by the 3MISP30s and 3MISP60s models in the testing group (p > 0.05). The results of the study showed that when the 3MISP60s test was used, the exercise intensity was significantly reduced, but the predictive effectiveness of VO2max did not change. We concluded that the 3MISP60s test was physiologically less stressful than the 3MISP30s test, and it could be a better choice for CRF evaluation.


2022 ◽  
Vol 28 ◽  
Author(s):  
Gabriela Cassemiliano ◽  
Paula Angélica Ricci ◽  
Soraia Pilon Jürgensen ◽  
Bianca Cristina Domingos ◽  
Audrey Borghi-Silva

2022 ◽  
Vol 28 (spe1) ◽  
Author(s):  
Míriam Raquel Meira Mainenti ◽  
Patrícia dos Santos Vigário ◽  
Hugo Brito Batista ◽  
Luiz Fernando Valverde Bastos ◽  
Danielli Braga de Mello

Sign in / Sign up

Export Citation Format

Share Document