Delay Fixation of Trochanteric Fractures Using Dynamic Hip Screw: A Minimally Invasive Technique

2006 ◽  
Vol 21 (2) ◽  
pp. 109-114
Author(s):  
Banchong Mahaisavariya ◽  
Kongkhet Riansuwan
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
A. Mahmood ◽  
M. Kalra ◽  
M. K. Patralekh

Background. Intertrochanteric fractures of the proximal femur are one of the most common fractures encountered, and dynamic hip screw with a side plate is the standard treatment. We compared a minimally invasive surgical technique with the conventional surgical technique used in the fixation of intertrochanteric fractures with the dynamic hip screw (DHS) device. Methods. Thirty patients with such fractures were treated with the conventional open technique and 30 with a new minimally invasive technique. Patients in both groups were followed up for 1 year. Results. There was less blood loss, minimal soft tissue destruction, shorter hospital stay, and early mobilization with the minimally invasive technique. Conclusion. The present study finds minimally invasive technique superior to conventional (open) DHS.


Author(s):  
RICARDO RAMON CAMACHO IRIGOYEN ◽  
RAFAEL DE LUCA DE-LUCENA ◽  
JEAN KLAY SANTOS MACHADO ◽  
GABRIEL SEVERO DA-SILVA ◽  
CARLOS ROBERTO SCHWARTSMANN ◽  
...  

ABSTRACT Introduction: the number of hip fractures is estimated to increase from 1.66 million in 1990 to 6.26 million by 2050. Internal fixation is the most common surgical treatment for intertrochanteric fractures. Objectives: the objective of the present research is to describe a minimally invasive technique with a modified instrument for the treatment of stable proximal femoral trochanteric fractures using the standard DHS, classified as Tronzo types 1 and 2 (AO 31A1.2), and presenting a case series. Methods: a case was selected to present the technique. Patients operated by this technique undergo a clinical evaluation and preoperative preparation as routine. The criteria for inclusion in the study were the presence of stable fracture of the proximal femur verified by two hip specialist orthopedists, and operated by the minimally invasive technique with a modified instrument using a standard DHS. Exclusion criteria were cases of patients operated for unstable fractures, and the use of other surgical techniques. A case series of 98 patients was performed and discussed. Results: minimally invasive technique with a modified instrument using the standard DHS device can reduce bleeding, it decreases soft tissue injuries, surgical time, and hospital stay, as any other MIPO procedures. Ninety-eight patients underwent the operation (Tronzo types I and II), 59 female and 39 male, ages from 50 to 85 years old. Immediate post-operative complications were shortening of the lower limb, loss of fracture reduction, and death by clinical complications. Conclusion: the present study describes a minimally invasive surgical technique using a modified instrument to perform proximal femoral osteosynthesis for stable trochanteric fractures, using the standard DHS.


2021 ◽  
pp. 155335062098822
Author(s):  
Eirini Giovannopoulou ◽  
Anastasia Prodromidou ◽  
Nikolaos Blontzos ◽  
Christos Iavazzo

Objective. To review the existing studies on single-site robotic myomectomy and test the safety and feasibility of this innovative minimally invasive technique. Data Sources. PubMed, Scopus, Google Scholar (from their inception to October 2019), as well as Clinicaltrials.gov databases up to April 2020. Methods of Study Selection. Clinical trials (prospective or retrospective) that reported the outcomes of single-site robotic myomectomy, with a sample of at least 20 patients were considered eligible for the review. Results. The present review was performed in accordance with the guidelines for Systematic Reviews and Meta-Analyses (PRISMA). Four (4) studies met the inclusion criteria, and a total of 267 patients were included with a mean age from 37.1 to 39.1 years and BMI from 21.6 to 29.4 kg/m2. The mean operative time ranged from 131.4 to 154.2 min, the mean docking time from 5.1 to 5.45 min, and the mean blood loss from 57.9 to 182.62 ml. No intraoperative complications were observed, and a conversion rate of 3.8% was reported by a sole study. The overall postoperative complication rate was estimated at 2.2%, and the mean hospital stay ranged from 0.57 to 4.7 days. No significant differences were detected when single-site robotic myomectomy was compared to the multiport technique concerning operative time, blood loss, and total complication rate. Conclusion. Our findings support the safety of single-site robotic myomectomy and its equivalency with the multiport technique on the most studied outcomes. Further studies are needed to conclude on the optimal minimally invasive technique for myomectomy.


1991 ◽  
Vol 5 (2) ◽  
pp. 117-122 ◽  
Author(s):  
STEPHENIE R. LONG ◽  
RALPH V. CLAYMAN ◽  
STEPHEN M. DIERKS ◽  
SHIMON MERETYK ◽  
TERRY BUELNA

Sign in / Sign up

Export Citation Format

Share Document