scholarly journals Is It More Informative to Focus on Cardiac Output than Blood Pressure during Spinal Anesthesia for Cesarean Delivery in Women with Severe Preeclampsia?

2008 ◽  
Vol 108 (5) ◽  
pp. 771-772 ◽  
Author(s):  
Eldrid Langesæter
2015 ◽  
Vol 122 (4) ◽  
pp. 736-745 ◽  
Author(s):  
Warwick D. Ngan Kee ◽  
Shara W. Y. Lee ◽  
Floria F. Ng ◽  
Perpetua E. Tan ◽  
Kim S. Khaw

Abstract Background: During spinal anesthesia for cesarean delivery, phenylephrine can cause reflexive decreases in maternal heart rate and cardiac output. Norepinephrine has weak β-adrenergic receptor agonist activity in addition to potent α-adrenergic receptor activity and therefore may be suitable for maintaining blood pressure with less negative effects on heart rate and cardiac output compared with phenylephrine. Methods: In a randomized, double-blinded study, 104 healthy patients having cesarean delivery under spinal anesthesia were randomized to have systolic blood pressure maintained with a computer-controlled infusion of norepinephrine 5 μg/ml or phenylephrine 100 μg/ml. The primary outcome compared was cardiac output. Blood pressure heart rate and neonatal outcome were also compared. Results: Normalized cardiac output 5 min after induction was greater in the norepinephrine group versus the phenylephrine group (median 102.7% [interquartile range, 94.3 to 116.7%] versus 93.8% [85.0 to 103.1%], P = 0.004, median difference 9.8%, 95% CI of difference between medians 2.8 to 16.1%). From induction until uterine incision, for norepinephrine versus phenylephrine, systolic blood pressure and stroke volume were similar, heart rate and cardiac output were greater, systemic vascular resistance was lower, and the incidence of bradycardia was smaller. Neonatal outcome was similar between groups. Conclusions: When given by computer-controlled infusion during spinal anesthesia for cesarean delivery, norepinephrine was effective for maintaining blood pressure and was associated with greater heart rate and cardiac output compared with phenylephrine. Further work would be of interest to confirm the safety and efficacy of norepinephrine as a vasopressor in obstetric patients.


2008 ◽  
Vol 108 (5) ◽  
pp. 802-811 ◽  
Author(s):  
Robert A. Dyer ◽  
Jenna L. Piercy ◽  
Anthony R. Reed ◽  
Carl J. Lombard ◽  
Leann K. Schoeman ◽  
...  

Background Hemodynamic responses to spinal anesthesia (SA) for cesarean delivery in patients with severe preeclampsia are poorly understood. This study used a beat-by-beat monitor of cardiac output (CO) to characterize the response to SA. The hypothesis was that CO would decrease from baseline values by less than 20%. Methods Fifteen patients with severe preeclampsia consented to an observational study. The monitor employed used pulse wave form analysis to estimate nominal stroke volume. Calibration was by lithium dilution. CO and systemic vascular resistance were derived from the measured stroke volume, heart rate, and mean arterial pressure. In addition, the hemodynamic effects of phenylephrine, the response to delivery and oxytocin, and hemodynamics during recovery from SA were recorded. Hemodynamic values were averaged for defined time intervals before, during, and after SA. Results Cardiac output remained stable from induction of SA until the time of request for analgesia. Mean arterial pressure and systemic vascular resistance decreased significantly from the time of adoption of the supine position until the end of surgery. After oxytocin administration, systemic vascular resistance decreased and heart rate and CO increased. Phenylephrine, 50 mug, increased mean arterial pressure to above target values and did not significantly change CO. At the time of recovery from SA, there were no clinically relevant changes from baseline hemodynamic values. Conclusions Spinal anesthesia in severe preeclampsia was associated with clinically insignificant changes in CO. Phenylephrine restored mean arterial pressure but did not increase maternal CO. Oxytocin caused transient marked hypotension, tachycardia, and increases in CO.


2008 ◽  
Vol 109 (5) ◽  
pp. 856-863 ◽  
Author(s):  
Eldrid Langesæter ◽  
Leiv Arne Rosseland ◽  
Audun Stubhaug

Background Prevention of hemodynamic instability during cesarean delivery during spinal anesthesia has been the aim of several studies. Noninvasive monitoring has been used in all previous studies. This is the first study in healthy pregnant women with continuous invasive recording of arterial blood pressure, cardiac output, and systemic vascular resistance. The aim of this randomized trial was to compare the effects of two different intrathecal doses of bupivacaine, with or without intravenous phenylephrine infusion, on cardiac output and systolic blood pressure. Methods In this double-blinded study, 80 healthy women scheduled to undergo elective cesarean delivery were randomly assigned to one of four different groups receiving 7 mg spinal bupivacaine with or without a concomitant low-dose infusion of phenylephrine (0.25 microg . kg(-1) . min(-1)) or 10 mg spinal bupivacaine with or without phenylephrine infusion. All patients had 4 microg sufentanil added to the spinal solution and had cohydration with 750 ml saline, 0.9%. Results The low-dose spinal bupivacaine group with intravenous phenylephrine infusion was the most stable group regarding all hemodynamic variables. The authors found significant differences between this group and the group that was given the high dose of bupivacaine with intravenous placebo infusion regarding cardiac output (P = 0.005), systemic vascular resistance (P < 0.0001), and systolic blood pressure (P = 0.012). Conclusions This study shows that low-dose bupivacaine (with sufentanil), combined with a low-dose infusion of phenylephrine and moderate cohydration, gives the best hemodynamic stability during spinal anesthesia for cesarean delivery.


F1000Research ◽  
2018 ◽  
Vol 7 ◽  
pp. 1028 ◽  
Author(s):  
Markos Erango ◽  
Arnoldo Frigessi ◽  
Leiv Arne Rosseland

Background: Cesarean delivery is performed under spinal anesthesia, and vasodilation is the main cause for a drop in blood pressure. The compression of the aorta and inferior vena cava by the gravid uterus is of additional clinical importance. Hypotension may occur during cesarean delivery even if prophylactic infusion of phenylephrine is practiced. We have tested if a 3 minute supine observation, can identify a subset of women with decreasing systolic arterial pressure (SAP) under spinal anesthesia. Methods: We performed a prospective observational study at Oslo University Hospital on healthy pregnant women for planned cesarean delivery. Continuous measurements of calibrated invasive SAP and estimated cardiac output were recorded for 76 women in a 3 minutes measurement with the woman in the left lateral position, followed by supine position for 3 minutes. Using functional data clustering, principal component analysis and curve smoothing, to filter way noise and reduce the dimensionality of the signal, we clustered the women into separate SAP groups.   Results: We identified two significantly different groups of women during supine position; one characterized by initial drop in SAP, the other showed initial increase. After spinal anesthesia, the mean SAP curve of the women in the first group showed a drop in blood pressure, which was more rapid than for the other women. A minor difference in cardiac output was observed between the two groups of women with the mean cardiac output curve for the first group being higher. Conclusions: This work indicates that supine position affect clinically relevant cardiovascular measurements in pregnant women. A simple test may identify patients with increased risk of spinal anesthesia induced hypotension.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Mohamed I Shahin ◽  
Ayman M Kamaly ◽  
Mohamed Saleh ◽  
Ashraf E El-Agamy

Abstract Background Spinal anesthesia is the preferred method for elective cesarean sections (C.S.) due to considerable risks regarding airway management associated with physiological changes of pregnancy. Hypotension is reported to occur in up to 80% of spinal anesthesia cases. Many approaches have been investigated to prevent spinal hypotension, e.g., fluid loading, vasopressors, or both. Thus we compare the administration of intermittent I.V. boluses of norepinephrine and ephedrine to guard against the hypotensive effect of spinal anesthesia during cesarean delivery. Patients and Methods 120 female patients undergoing electiveC.S.were randomly divided into “group-E” for Ephedrine and “group-N” for Norepinephrine. Results Compared with ephedrine, norepinephrine maintained maternal blood pressure and uterine artery blood flow. Further, it was associated with lower numbers of hypotension and hypertension episodes and less frequency of bradycardia and tachycardia during cesarean delivery. Conclusion Norepinephrine can be used as an alternative vasopressor to maintain maternal blood pressure during spinal anesthesia for cesarean delivery, with no adverse effect on neonatal outcome.


Sign in / Sign up

Export Citation Format

Share Document