scholarly journals Sound Localization in Noise by Normal-Hearing Listeners and Cochlear Implant Users

2012 ◽  
Vol 33 (4) ◽  
pp. 445-457 ◽  
Author(s):  
Stefan Kerber ◽  
Bernhard U. Seeber
2021 ◽  
Vol 12 ◽  
Author(s):  
Alexandra Annemarie Ludwig ◽  
Sylvia Meuret ◽  
Rolf-Dieter Battmer ◽  
Marc Schönwiesner ◽  
Michael Fuchs ◽  
...  

Spatial hearing is crucial in real life but deteriorates in participants with severe sensorineural hearing loss or single-sided deafness. This ability can potentially be improved with a unilateral cochlear implant (CI). The present study investigated measures of sound localization in participants with single-sided deafness provided with a CI. Sound localization was measured separately at eight loudspeaker positions (4°, 30°, 60°, and 90°) on the CI side and on the normal-hearing side. Low- and high-frequency noise bursts were used in the tests to investigate possible differences in the processing of interaural time and level differences. Data were compared to normal-hearing adults aged between 20 and 83. In addition, the benefit of the CI in speech understanding in noise was compared to the localization ability. Fifteen out of 18 participants were able to localize signals on the CI side and on the normal-hearing side, although performance was highly variable across participants. Three participants always pointed to the normal-hearing side, irrespective of the location of the signal. The comparison with control data showed that participants had particular difficulties localizing sounds at frontal locations and on the CI side. In contrast to most previous results, participants were able to localize low-frequency signals, although they localized high-frequency signals more accurately. Speech understanding in noise was better with the CI compared to testing without CI, but only at a position where the CI also improved sound localization. Our data suggest that a CI can, to a large extent, restore localization in participants with single-sided deafness. Difficulties may remain at frontal locations and on the CI side. However, speech understanding in noise improves when wearing the CI. The treatment with a CI in these participants might provide real-world benefits, such as improved orientation in traffic and speech understanding in difficult listening situations.


2017 ◽  
Vol 26 (4) ◽  
pp. 519-530
Author(s):  
Yunfang Zheng ◽  
Janet Koehnke ◽  
Joan Besing

Purpose This study examined the individual and combined effects of noise and reverberation on the ability of listeners with normal hearing (NH) and with bilateral cochlear implants (BCIs) to localize speech. Method Six adults with BCIs and 10 with NH participated. All subjects completed a virtual localization test in quiet and at 0-, −4-, and −8-dB signal-to-noise ratios (SNRs) in simulated anechoic and reverberant (0.2-, 0.6-, and 0.9-s RT 60 ) environments. BCI users were also tested at +8- and +4-dB SNR. A 3-word phrase was presented at 70 dB SPL from 9 simulated locations in the frontal horizontal plane (±90°), with the noise source at 0°. Results BCIs users had significantly poorer localization than listeners with NH in all conditions. BCI users' performance started to decrease at a higher SNR (+4 dB) and shorter RT 60 (0.2 s) than listeners with NH (−4 dB and 0.6 s). The combination of noise and reverberation began to degrade localization of BCI users at a higher SNR and a shorter RT 60 than listeners with NH. Conclusion The clear effect of noise and reverberation on the performance of BCI users provides information that should be useful for refining cochlear implant processing strategies and developing cochlear implant rehabilitation plans to optimize binaural benefit for BCI users in everyday listening situations.


2019 ◽  
Vol 23 ◽  
pp. 233121651984733 ◽  
Author(s):  
Sebastian A. Ausili ◽  
Bradford Backus ◽  
Martijn J. H. Agterberg ◽  
A. John van Opstal ◽  
Marc M. van Wanrooij

Bilateral cochlear-implant (CI) users and single-sided deaf listeners with a CI are less effective at localizing sounds than normal-hearing (NH) listeners. This performance gap is due to the degradation of binaural and monaural sound localization cues, caused by a combination of device-related and patient-related issues. In this study, we targeted the device-related issues by measuring sound localization performance of 11 NH listeners, listening to free-field stimuli processed by a real-time CI vocoder. The use of a real-time vocoder is a new approach, which enables testing in a free-field environment. For the NH listening condition, all listeners accurately and precisely localized sounds according to a linear stimulus–response relationship with an optimal gain and a minimal bias both in the azimuth and in the elevation directions. In contrast, when listening with bilateral real-time vocoders, listeners tended to orient either to the left or to the right in azimuth and were unable to determine sound source elevation. When listening with an NH ear and a unilateral vocoder, localization was impoverished on the vocoder side but improved toward the NH side. Localization performance was also reflected by systematic variations in reaction times across listening conditions. We conclude that perturbation of interaural temporal cues, reduction of interaural level cues, and removal of spectral pinna cues by the vocoder impairs sound localization. Listeners seem to ignore cues that were made unreliable by the vocoder, leading to acute reweighting of available localization cues. We discuss how current CI processors prevent CI users from localizing sounds in everyday environments.


2010 ◽  
Vol 10 ◽  
pp. 329-339 ◽  
Author(s):  
Torsten Rahne ◽  
Michael Ziese ◽  
Dorothea Rostalski ◽  
Roland Mühler

This paper describes a logatome discrimination test for the assessment of speech perception in cochlear implant users (CI users), based on a multilingual speech database, the Oldenburg Logatome Corpus, which was originally recorded for the comparison of human and automated speech recognition. The logatome discrimination task is based on the presentation of 100 logatome pairs (i.e., nonsense syllables) with balanced representations of alternating “vowel-replacement” and “consonant-replacement” paradigms in order to assess phoneme confusions. Thirteen adult normal hearing listeners and eight adult CI users, including both good and poor performers, were included in the study and completed the test after their speech intelligibility abilities were evaluated with an established sentence test in noise. Furthermore, the discrimination abilities were measured electrophysiologically by recording the mismatch negativity (MMN) as a component of auditory event-related potentials. The results show a clear MMN response only for normal hearing listeners and CI users with good performance, correlating with their logatome discrimination abilities. Higher discrimination scores for vowel-replacement paradigms than for the consonant-replacement paradigms were found. We conclude that the logatome discrimination test is well suited to monitor the speech perception skills of CI users. Due to the large number of available spoken logatome items, the Oldenburg Logatome Corpus appears to provide a useful and powerful basis for further development of speech perception tests for CI users.


2015 ◽  
Vol 54 (06) ◽  
pp. 500-504 ◽  
Author(s):  
A. G. Maglione ◽  
A. Scorpecci ◽  
P. Malerba ◽  
P. Marsella ◽  
S. Giannantonio ◽  
...  

SummaryObjectives: The aim of the present study is to investigate the variations of the electroencephalographic (EEG) alpha rhythm in order to measure the appreciation of bilateral and unilateral young cochlear implant users during the observation of a musical cartoon. The cartoon has been modified for the generation of three experimental conditions: one with the original audio, another one with a distorted sound and, finally, a mute version.Methods: The EEG data have been recorded during the observation of the cartoons in the three experimental conditions. The frontal alpha EEG imbalance has been calculated as a measure of motivation and pleasantness to be compared across experimental populations and conditions.Results: The EEG frontal imbalance of the alpha rhythm showed significant variations during the perception of the different cartoons. In particular, the pattern of activation of normal-hearing children is very similar to the one elicited by the bilateral implanted patients. On the other hand, results related to the unilateral subjects do not present significant variations of the imbalance index across the three cartoons.Conclusion: The presented results suggest that the unilateral patients could not appreciate the difference in the audio format as well as bilaterally implanted and normal hearing subjects. The frontal alpha EEG imbalance is a useful tool to detect the differences in the appreciation of audiovisual stimuli in cochlear implant patients.


2015 ◽  
Vol 43 (2) ◽  
pp. 310-337 ◽  
Author(s):  
MARCEL R. GIEZEN ◽  
PAOLA ESCUDERO ◽  
ANNE E. BAKER

AbstractThis study investigates the role of acoustic salience and hearing impairment in learning phonologically minimal pairs. Picture-matching and object-matching tasks were used to investigate the learning of consonant and vowel minimal pairs in five- to six-year-old deaf children with a cochlear implant (CI), and children of the same age with normal hearing (NH). In both tasks, the CI children showed clear difficulties with learning minimal pairs. The NH children also showed some difficulties, however, particularly in the picture-matching task. Vowel minimal pairs were learned more successfully than consonant minimal pairs, particularly in the object-matching task. These results suggest that the ability to encode phonetic detail in novel words is not fully developed at age six and is affected by task demands and acoustic salience. CI children experience persistent difficulties with accurately mapping sound contrasts to novel meanings, but seem to benefit from the relative acoustic salience of vowel sounds.


Sign in / Sign up

Export Citation Format

Share Document