Empiric Antibiotic Treatment Reduces Mortality in Severe Sepsis and Septic Shock From the First Hour

2014 ◽  
Vol 42 (8) ◽  
pp. 1749-1755 ◽  
Author(s):  
Ricard Ferrer ◽  
Ignacio Martin-Loeches ◽  
Gary Phillips ◽  
Tiffany M. Osborn ◽  
Sean Townsend ◽  
...  
2016 ◽  
Vol 17 (2) ◽  
pp. 210-216 ◽  
Author(s):  
Taku Oshima ◽  
Yoshiyuki Kodama ◽  
Waka Takahashi ◽  
Yosuke Hayashi ◽  
Shinya Iwase ◽  
...  

2004 ◽  
Vol 38 (2) ◽  
pp. 284-288 ◽  
Author(s):  
Rodger D. MacArthur ◽  
Mark Miller ◽  
Timothy Albertson ◽  
Edward Panacek ◽  
David Johnson ◽  
...  

2015 ◽  
Vol 43 (10) ◽  
pp. 2258-2259 ◽  
Author(s):  
Marya D. Zilberberg ◽  
Andrew F. Shorr

2018 ◽  
Vol 8 (1) ◽  
Author(s):  
Andreas Hohn ◽  
Nina Balfer ◽  
Bernhard Heising ◽  
Sabine Hertel ◽  
Jan C. Wiemer ◽  
...  

MedPharmRes ◽  
2018 ◽  
Vol 2 (3) ◽  
pp. 27-32
Author(s):  
Bien Le ◽  
Dai Huynh ◽  
Mai Tuan ◽  
Minh Phan ◽  
Thao Pham ◽  
...  

Objectives: to evaluate the fluid responsiveness according to fluid bolus triggers and their combination in severe sepsis and septic shock. Design: observational study. Patients and Methods: patients with severe sepsis and septic shock who already received fluid after rescue phase of resuscitation. Fluid bolus (FB) was prescribed upon perceived hypovolemic manifestations: low central venous pressure (CVP), low blood pressure, tachycardia, low urine output (UOP), hyperlactatemia. FB was performed by Ringer lactate 500 ml/30 min and responsiveness was defined by increasing in stroke volume (SV) ≥15%. Results: 84 patients were enrolled, among them 30 responded to FB (35.7%). Demographic and hemodynamic profile before fluid bolus were similar between responders and non-responders, except CVP was lower in responders (7.3 ± 3.4 mmHg vs 9.2 ± 3.6 mmHg) (p 0.018). Fluid response in low CVP, low blood pressure, tachycardia, low UOP, hyperlactatemia were 48.6%, 47.4%, 38.5%, 37.0%, 36.8% making the odd ratio (OR) of these triggers were 2.81 (1.09-7.27), 1.60 (0.54-4.78), 1.89 (0.58-6.18), 1.15 (0.41-3.27) and 1.27 (0.46-3.53) respectively. Although CVP < 8 mmHg had a higher response rate, the association was not consistent at lower cut-offs. The combination of these triggers appeared to raise fluid response but did not reach statistical significance: 26.7% (1 trigger), 31.0% (2 triggers), 35.7% (3 triggers), 55.6% (4 triggers), 100% (5 triggers). Conclusions: fluid responsiveness was low in optimization phase of resuscitation. No fluid bolus trigger was superior to the others in term of providing a higher responsiveness, their combination did not improve fluid responsiveness as well.


Sign in / Sign up

Export Citation Format

Share Document