scholarly journals Printing a Patient-Specific Instrument Guide for Skull Osteoma Management

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Tien-Hsiang Wang ◽  
Hsu Ma ◽  
Li-Ying Huang ◽  
Yu-Cheng Hung ◽  
Te-Han Wang ◽  
...  
2019 ◽  
Author(s):  
A Darwood ◽  
◽  
S Hurst ◽  
G Villatte ◽  
R Fenton ◽  
...  

2020 ◽  
Vol Volume 12 ◽  
pp. 6533-6540
Author(s):  
Daniel A Müller ◽  
Yannik Stutz ◽  
Lazaros Vlachopoulos ◽  
Mazda Farshad ◽  
Philipp Fürnstahl

The Knee ◽  
2019 ◽  
Vol 26 (6) ◽  
pp. 1421-1428 ◽  
Author(s):  
Gareth G. Jones ◽  
Susannah Clarke ◽  
Simon Harris ◽  
Martin Jaere ◽  
Thunayan Aldalmani ◽  
...  

2020 ◽  
Vol 8 (9_suppl7) ◽  
pp. 2325967120S0054
Author(s):  
Wang Yuehui ◽  
Zou Shiping ◽  
Cao Liangliang ◽  
Chen Wenzhong

Introduction: To invest the auxiliary role of Patient specific Instrument(PSI) used as osteotomy guide plate in total knee arthroplasty(TKA) with valgus knee. Hypotheses: PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee. Methods: A retrospective analysis was performed on 21 patients with valgus knee, including 5 males and 16 females, who underwent TKA in joint surgery department I of ZhengZhou Orthopaedic Hospital from March 2016 to February 2018. All the operations were performed with the assistance of PSI, and the radiographic and clinical evaluations including femoral tibial joint ectropion angle(FTA) before and after operation, range of motion(ROM) and the Hospital for Special Surgery (HSS) knee score were reviewed, and surgical complications were recorded. Results: All the 21 patients werefollowed up for 10 ˜ 26 months (mean 16 months).All the incisions healed by first intention. The FTA was reduced significantly to 6.3 °±1.2° after operation from 17.6 ° + 5.7 °(P < 0.05), the ROM was improved significantly from preoperative 71.3° ±5.8° to postoperative 102.4°±7.5° (P < 0.05), the HSS score at the last follow-up was improved from 38.2±5.7 to 87.5-3.5(P < 0.05). During the follow-up, no complications such as infection, loosening, sinking and valgus were observed. Conclusion: Providing accurate osteotomy, effective correction of the force line, simple operation and satisfactory clinical effect, the PSI osteotomy guide plate is applicable for total knee arthroplasty with valgus knee.


Orthopedics ◽  
2016 ◽  
Vol 40 (2) ◽  
pp. e374-e377 ◽  
Author(s):  
Hideya Ito ◽  
Shigeyuki Tanaka ◽  
Takeyuki Tanaka ◽  
Hirofumi Oshima ◽  
Sakae Tanaka

Sign in / Sign up

Export Citation Format

Share Document