Diagnostic Potential of Endotoxin Scattering Photometry for Sepsis and Septic Shock

Shock ◽  
2013 ◽  
Vol 40 (6) ◽  
pp. 504-511 ◽  
Author(s):  
Tomoharu Shimizu ◽  
Toru Obata ◽  
Hiromichi Sonoda ◽  
Hiroya Akabori ◽  
Tohru Miyake ◽  
...  
PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0261228
Author(s):  
Ngo Tat Trung ◽  
Tran Thi Lien ◽  
Vu Viet Sang ◽  
Nghiem Xuan Hoan ◽  
Nguyen Dang Manh ◽  
...  

Background Early diagnosis, precise antimicrobial treatment and subsequent patient stratification can improve sepsis outcomes. Circulating biomarkers such as plasma microRNAs (miRNAs) have proven to be surrogates for diagnosis, severity and case management of infections. The expression of four selected miRNAs (miR-146-3p, miR-147b, miR-155 and miR-223) was validated for their prognostic and diagnostic potential in a clinically defined cohort of patients with sepsis and septic shock. Methods The expression of plasma miRNAs was quantified by quantitative PCR (qPCR) in patients with bacterial sepsis (n = 78), in patients with septic shock (n = 52) and in patients with dengue haemorrhagic fever (DHF; n = 69) and in healthy controls (n = 82). Results The expression of studied miRNA was significantly increased in patients with bacterial sepsis and septic shock. The plasma miR-147b was able to differentiate bacterial sepsis from non-sepsis and septic shock (AUC = 0.77 and 0.8, respectively, p≤ 0.05), while the combination of plasma miR-147b and procalcitonin (PCT) predicted septic shock (AUC = 0.86, p≤ 0.05). Conclusions The plasma miR-147b may be an useful biomarker independently or in combination with PCT to support clinical diagnosis of sepsis and equally prognosis of patients with septic shock.


MedPharmRes ◽  
2018 ◽  
Vol 2 (3) ◽  
pp. 27-32
Author(s):  
Bien Le ◽  
Dai Huynh ◽  
Mai Tuan ◽  
Minh Phan ◽  
Thao Pham ◽  
...  

Objectives: to evaluate the fluid responsiveness according to fluid bolus triggers and their combination in severe sepsis and septic shock. Design: observational study. Patients and Methods: patients with severe sepsis and septic shock who already received fluid after rescue phase of resuscitation. Fluid bolus (FB) was prescribed upon perceived hypovolemic manifestations: low central venous pressure (CVP), low blood pressure, tachycardia, low urine output (UOP), hyperlactatemia. FB was performed by Ringer lactate 500 ml/30 min and responsiveness was defined by increasing in stroke volume (SV) ≥15%. Results: 84 patients were enrolled, among them 30 responded to FB (35.7%). Demographic and hemodynamic profile before fluid bolus were similar between responders and non-responders, except CVP was lower in responders (7.3 ± 3.4 mmHg vs 9.2 ± 3.6 mmHg) (p 0.018). Fluid response in low CVP, low blood pressure, tachycardia, low UOP, hyperlactatemia were 48.6%, 47.4%, 38.5%, 37.0%, 36.8% making the odd ratio (OR) of these triggers were 2.81 (1.09-7.27), 1.60 (0.54-4.78), 1.89 (0.58-6.18), 1.15 (0.41-3.27) and 1.27 (0.46-3.53) respectively. Although CVP < 8 mmHg had a higher response rate, the association was not consistent at lower cut-offs. The combination of these triggers appeared to raise fluid response but did not reach statistical significance: 26.7% (1 trigger), 31.0% (2 triggers), 35.7% (3 triggers), 55.6% (4 triggers), 100% (5 triggers). Conclusions: fluid responsiveness was low in optimization phase of resuscitation. No fluid bolus trigger was superior to the others in term of providing a higher responsiveness, their combination did not improve fluid responsiveness as well.


Sign in / Sign up

Export Citation Format

Share Document