scholarly journals The Concept of Functional Graft Size

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Koji Hashimoto ◽  
Charles M. Miller
Keyword(s):  
2017 ◽  
Vol 45 (10) ◽  
pp. 2260-2266 ◽  
Author(s):  
Kenneth J. Schmidt ◽  
Luís E. Tírico ◽  
Julie C. McCauley ◽  
William D. Bugbee

Background: Regulatory concerns and the popularity of fresh osteochondral allograft (OCA) transplantation have led to a need for prolonged viable storage of osteochondral grafts. Tissue culture media allow a longer storage time but lead to chondrocyte death within the tissue. The long-term clinical consequence of prolonged storage is unknown. Hypothesis: Patients transplanted with OCAs with a shorter storage time would have lower failure rates and better clinical outcomes than those transplanted with OCAs with prolonged storage. Study Design: Cohort study; Level of evidence, 3. Methods: A matched-pair study was performed of 75 patients who received early release grafts (mean storage, 6.3 days [range, 1-14 days]) between 1997 and 2002, matched 1:1 by age, diagnosis, and graft size, with 75 patients who received late release grafts (mean storage time, 20.0 days [range, 16-28 days]) from 2002 to 2008. The mean age was 33.5 years, and the median graft size was 6.3 cm2. All patients had a minimum 2-year follow-up. Evaluations included pain, satisfaction, function, failures, and reoperations. Outcome measures included the modified Merle d’Aubigné-Postel (18-point) scale, International Knee Documentation Committee (IKDC) form, and Knee Society function (KS-F) scale. Clinical failure was defined as revision OCA transplantation or conversion to arthroplasty. Results: Among patients with grafts remaining in situ, the mean follow-up was 11.9 years (range, 2.0-16.8 years) and 7.8 years (range, 2.3-11.1 years) for the early and late release groups, respectively. OCA failure occurred in 25.3% (19/75) of patients in the early release group and 12.0% (9/75) of patients in the late release group ( P = .036). The median time to failure was 3.5 years (range, 1.7-13.8 years) and 2.7 years (range, 0.3-11.1 years) for the early and late release groups, respectively. The 5-year survivorship of OCAs was 85% for the early release group and 90% for the late release group ( P = .321). No differences in postoperative pain and function were noted between the groups. Ninety-one percent of the early release group and 93% of the late release group reported satisfaction with OCA results. Conclusion: The transplantation of OCA tissue with prolonged storage is safe and effective for large osteochondral lesions of the knee and has similar clinical outcomes and satisfaction to the transplantation of early release grafts.


2016 ◽  
Vol 22 (5) ◽  
pp. 599-606 ◽  
Author(s):  
Shigeru Marubashi ◽  
Hiroaki Nagano ◽  
Hidetoshi Eguchi ◽  
Hiroshi Wada ◽  
Tadafumi Asaoka ◽  
...  

2006 ◽  
Vol 175 (1) ◽  
pp. 235-236
Author(s):  
L. de Santis Feltran ◽  
P.C.K. Nogueira ◽  
A.P. Bocaletti ◽  
D.M.J. Christofalo ◽  
S.A. Ajzen ◽  
...  
Keyword(s):  

Cureus ◽  
2020 ◽  
Author(s):  
Oscar A Vazquez ◽  
Moses I Markowitz ◽  
Hilton Becker

1999 ◽  
Vol 30 (4) ◽  
pp. 658-667 ◽  
Author(s):  
Geert Willem H. Schurink ◽  
Nico J.M. Aarts ◽  
Jary M. van Baalen ◽  
Leo J. Schultze Kool ◽  
J.Hajo van Bockel

2001 ◽  
Vol 71 (10) ◽  
pp. 1407-1413 ◽  
Author(s):  
Seisuke Sakamoto ◽  
Shinji Uemoto ◽  
Kenji Uryuhara ◽  
Il-deok Kim ◽  
Tetsuya Kiuchi ◽  
...  

2018 ◽  
Vol 6 (6) ◽  
pp. 232596711877978 ◽  
Author(s):  
Prem N. Ramkumar ◽  
Michael D. Hadley ◽  
Morgan H. Jones ◽  
Lutul D. Farrow

Background: Small-diameter autograft hamstring grafts have been linked to graft failure after anterior cruciate ligament (ACL) reconstruction. The frequency of hamstring autografts that actually meet ideal size criteria remains unknown. Purpose: To examine a large cohort of patients to (1) evaluate sizing variability among a large cohort of surgeons and (2) identify patient factors most predictive of hamstring autograft size. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 1681 ACL reconstructions with hamstring autograft were analyzed as completed by 11 surgeons over a 13-year period. Patient demographics (age, height, weight, body mass index, sex) and intraoperative details (including graft diameter and strands) were extracted. Univariate and multivariate regression analyses were performed to correlate patient demographics with graft size and to develop a predictive model for hamstring graft size. Results: The mean height and weight of patients included in this study were 172.7 cm and 80.1 kg, respectively; 59% of patients were male. The mean diameters of hamstring autografts were 8.4 mm and 8.2 mm for the tibial and femoral ends of the graft, respectively. A total of 55.1% of grafts were ≤8 mm. Mixed-effects linear modeling revealed that height, weight, sex, and use of ≥5 strands correlated with graft size ( P < .001), while age did not. The predictive multivariate model based on the statistically relevant factors demonstrated a moderate correlation ( r = 0.39, R2 = 0.150), illustrated a predictive equation, and proved height to be the greatest determinant of graft size. Conclusion: Marked variability in graft size distribution was found among surgeons, and more than half of all grafts did not reach the ideal size for hamstring autograft ACL reconstruction. A predictive equation including anthropometric factors may be able to provide the expected graft size. The risk of early graft failure may be mitigated with preoperative consideration of anthropometric factors—most importantly, height—in preparation for possible augmentation, additional strands, or alternative graft sources.


2021 ◽  
Vol 9 (12) ◽  
pp. 232596712110566
Author(s):  
Soroush Baghdadi ◽  
David P. VanEenenaam ◽  
Brendan A. Williams ◽  
J. Todd R. Lawrence ◽  
Kathleen J. Maguire ◽  
...  

Background: There is increased interest in quadriceps autograft anterior cruciate ligament (ACL) reconstruction in the pediatric population. Purpose: To evaluate children and adolescents who underwent ACL reconstruction using a quadriceps autograft to determine the properties of the harvested graft and to assess the value of demographic, anthropometric, and magnetic resonance imaging (MRI) measurements in predicting the graft size preoperatively. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A retrospective database search was performed from January 2018 through October 2020 for patients undergoing ACL reconstruction. Patients <18 years old at the time of surgery in whom a quadriceps tendon autograft was used were selected. Demographic data and anthropometric measurements were recorded, and graft measurements were abstracted from the operative notes. Knee MRI scans were reviewed to measure the quadriceps tendon thickness on sagittal cuts. Graft length and diameter were then correlated with anthropometric and radiographic data. Results: A total of 169 patients (98 male) were included in the final analysis, with a median age of 15 years (range, 9-17 years). A tendon length ≥65 mm was harvested in 159 (94%) patients. The final graft diameter was 8.4 ± 0.7 mm (mean ± SD; range, 7-11 mm). All patients had a graft diameter ≥7 mm, and 139 (82%) had a diameter ≥8 mm. Preconditioning decreased the graft diameter by a mean 0.67 ± 0.23 mm. Age ( P = .04) and quadriceps thickness on MRI ( P = .003) were significant predictors of the final graft diameter. An MRI sagittal thickness >6.7 mm was 97.4% sensitive for obtaining a graft ≥8 mm in diameter. Conclusion: Our findings suggest that tendon-only quadriceps autograft is a reliable graft source in pediatric ACL reconstruction, yielding a graft diameter ≥8 mm in 82% of pediatric patients. Furthermore, preoperative MRI measurements can be reliably used to predict a graft of adequate diameter in children and adolescents undergoing ACL reconstruction, with a sagittal thickness >6.7 mm being highly predictive of a final graft size ≥8 mm.


Sign in / Sign up

Export Citation Format

Share Document