A Pixel-Array Detector for Time-Resolved X-ray Diffraction

1998 ◽  
Vol 5 (3) ◽  
pp. 252-255 ◽  
Author(s):  
E. F. Eikenberry ◽  
S. L. Barna ◽  
M. W. Tate ◽  
G. Rossi ◽  
R. L. Wixted ◽  
...  

An integrating pixel-array detector for recording time-resolved X-ray diffraction measurements on microsecond timescales has been designed and tested as a 4 × 4 pixel prototype. Operational characteristics and radiation tolerance are discussed. A 100 × 92 array with 151.2 µm square pixels is currently under construction.

1997 ◽  
Vol 44 (3) ◽  
pp. 950-956 ◽  
Author(s):  
S.L. Barna ◽  
J.A. Shepherd ◽  
M.W. Tate ◽  
R.L. Wixted ◽  
E.F. Eikenberry ◽  
...  

1995 ◽  
Author(s):  
Sandor L. Barna ◽  
John A. Shepherd ◽  
Robert L. Wixted ◽  
Mark W. Tate ◽  
Brian G. Rodricks ◽  
...  

1999 ◽  
Vol 6 (6) ◽  
pp. 1096-1105 ◽  
Author(s):  
G. Rossi ◽  
M. Renzi ◽  
E. F. Eikenberry ◽  
M. W. Tate ◽  
D. Bilderback ◽  
...  

1996 ◽  
Vol 67 (9) ◽  
pp. 3360-3360
Author(s):  
Brian G. Rodricks ◽  
Sandor L. Barna ◽  
Sol M. Gruner ◽  
John A. Shepherd ◽  
Mark W. Tate ◽  
...  

2022 ◽  
Vol 29 (1) ◽  
Author(s):  
Kewin Desjardins ◽  
Cristian Mocuta ◽  
Arkadiusz Dawiec ◽  
Solenn Réguer ◽  
Philippe Joly ◽  
...  

One of the challenges of all synchrotron facilities is to offer the highest performance detectors for all their specific experiments, in particular for X-ray diffraction imaging and its high throughput data collection. In that context, the DiffAbs beamline, the Detectors and the Design and Engineering groups at Synchrotron SOLEIL, in collaboration with ImXPAD and Cegitek companies, have developed an original and unique detector with a circular shape. This detector is based on the hybrid pixel photon-counting technology and consists of the specific assembly of 20 hybrid pixel array detector (XPAD) modules. This article aims to demonstrate the main characteristics of the CirPAD (for Circular Pixel Array Detector) and its performance – i.e. excellent pixel quality, flat-field correction, high-count-rate performance, etc. Additionally, the powder X-ray diffraction pattern of an LaB6 reference sample is presented and refined. The obtained results demonstrate the high quality of the data recorded from the CirPAD, which allows the proposal of its use to all scientific communities interested in performing experiments at the DiffAbs beamline.


2016 ◽  
Author(s):  
Hugh T. Philipp ◽  
Mark W. Tate ◽  
Prafull Purohit ◽  
Darol Chamberlain ◽  
Katherine S. Shanks ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document