A plane-grating monochromator beamline for the PTB undulators at BESSY II

1998 ◽  
Vol 5 (3) ◽  
pp. 780-782 ◽  
Author(s):  
F. Senf ◽  
U. Flechsig ◽  
F. Eggenstein ◽  
W. Gudat ◽  
R. Klein ◽  
...  

At the BESSY II storage ring, the Physikalisch–Technische Bundesanstalt (PTB) will operate insertion devices dedicated to radiometric use. One branch of the appendant beamline system will be equipped with a grazing-incidence monochromator, described here. The monochromator concept is based on a plane grating operated in parallel light; therefore exact focusing is maintained for all photon energies irrespective of the angular setting at the grating. The monochromator has been optimized for small higher-order transmittance and high power throughput, as required by radiometric applications in the wide photon energy range from 20 eV to 1900 eV.

1998 ◽  
Vol 5 (3) ◽  
pp. 648-650 ◽  
Author(s):  
Hyun-Joon Shin ◽  
Y. Chung ◽  
Bongsoo Kim

The first insertion-device beamline at the Pohang Light Source is designed for high-resolution spectroscopy and spectromicroscopy. The beamline will contain a variable-included-angle plane-grating monochromator (VIA-PGM) using a grating substrate which has seven different grooves with different depths. The advantages of this scheme will be the fixed exit-slit position and the mechanical stability of the grating scan mechanism while changing the photon energy range. The beamline is designed to cover the photon energy range 20–2000 eV. The estimated spectral resolution, E/ΔE, is above 8000 in the photon energy range below 500 eV, and above 4000 for the remaining photon energy range. The estimated flux at the end-station is of the order of 1012 photons s−1 (0.1% bandwidth)−1.


1982 ◽  
Vol 195 (1-2) ◽  
pp. 245-250 ◽  
Author(s):  
P.K. Larsen ◽  
W.A.M. Van Bers ◽  
J.M. Bizau ◽  
F. Wuilleumier ◽  
S. Krummacher ◽  
...  

1998 ◽  
Vol 5 (3) ◽  
pp. 777-779 ◽  
Author(s):  
Eiji Shigemasa ◽  
Akio Toyoshima ◽  
Yonglian Yan ◽  
Tatsuji Hayaishi ◽  
Koichi Soejima ◽  
...  

The design and performance of a 24 m high-resolution spherical grating monochromator (H-SGM) for the undulator beamline (BL-16B) at the Photon Factory are described. With three interchangeable gratings of 400, 900 and 2000 lines mm−1, the H-SGM is designed to cover the photon energy range 40–600 eV. With a resolving power of approximately 2000 in the photon energy range 40–530 eV, more than 1011 photons s−1 have been measured. The best resolutions obtained so far, at a substantially lower photon flux, are greater than 10 000 at 250 eV and 8000 at 400 eV


1994 ◽  
Author(s):  
Karl-Heinz Stephan ◽  
Claus Reppin ◽  
Hans-Joerg Maier ◽  
Dagmar Frischke ◽  
Detlef Fuchs ◽  
...  

2012 ◽  
Vol 393 (1) ◽  
pp. 107-116 ◽  
Author(s):  
Martin Schwell ◽  
Yves Bénilan ◽  
Nicolas Fray ◽  
Marie-Claire Gazeau ◽  
Et. Es-Sebbar ◽  
...  

2018 ◽  
Vol 112 ◽  
pp. 11-15 ◽  
Author(s):  
Maria Christiansson ◽  
Christian Bernhardsson ◽  
Therése Geber-Bergstrand ◽  
Sören Mattsson ◽  
Christopher L. Rääf

Sign in / Sign up

Export Citation Format

Share Document