A 3-D Monte Carlo simulation of a small animal positron emission tomograph with millimeter spatial resolution

1999 ◽  
Vol 46 (3) ◽  
pp. 697-701 ◽  
Author(s):  
A. Bevilacqua ◽  
D. Bollini ◽  
A. Del Guerra ◽  
G. Di Domencio ◽  
M. Galli ◽  
...  
2016 ◽  
Vol 3 (1) ◽  
pp. 12-26 ◽  
Author(s):  
Malgorzata Z. Pajak ◽  
David Volgyes ◽  
Sally L. Pimlott ◽  
Carlos C. Salvador ◽  
Antonio S. Asensi ◽  
...  

Goals:This paper presents the performance review based on a dual-ring Positron Emission Tomography (PET) scanner being a part of Bruker Albira: a multi-modal small-animal imaging platform. Each ring of Albira PET contains eight detectors arranged as octagon, and each detector is built using a single continuous lutetium-yttrium oxyorthosilicate crystal and multi-anode photo multiplier tube. In two-ring configuration, the scanner covers 94.4 mm in axial- and 80´80 mm in trans-axial direction, which is sufficient to acquire images of small animals (e.g.mice) without the need of moving the animal bed during the scan.Methods:All measurements and majority of data processing were performed according to the NEMA NU4-2008 standard with one exception. Due to the scanner geometry, the spatial resolution test was reconstructed using iterative algorithm instead of the analytical one. The main performance characteristics were compared with those of the other PET sub-systems of tri-modal small-animal scanners.Results:The measured spatial resolution at the centre of the axial field of view in radial, tangential and axial directions was 1.72, 1.70 and 2.45 mm, respectively. The scatter fraction for the mouse-like phantom was 9.8% and for the rat-like phantom, 21.8%. The maximum absolute sensitivity was 5.30%. Finally, the recovery co-efficients for 5, 4, 3, 2, 1 mm diameter rods in image quality phantom were: 0.90, 0.77, 0.66, 0.30 and 0.05, respectively.Conclusion:The Bruker Albira is a versatile small-animal multi-modal device that can be used for variety of studies. Overall the PET sub-system provides a good spatial resolution coupled with better-than average sensitivity and the ability to produce good quality animal images when administering low activities.


2011 ◽  
Vol 46 (12) ◽  
pp. 2003-2005 ◽  
Author(s):  
Chung-Chi Lee ◽  
Ai-Mei Chen ◽  
Chuan-Jong Tung ◽  
Tsi-Chian Chao

Author(s):  
Mateus Gesulado Carneiro De Santana ◽  
Guilherme Cavalcante de Albuquerque Souza ◽  
Rodrigo Modesto Gadelha Gontijo ◽  
Bruno Melo Mendes ◽  
Andréa Vidal Ferreira

LabPET GE 4 (a small animal positron emission tomograph) image acquisition is done by 1536 independents channels. Differences in the rate counting of each channel must be corrected so as not compromise image quality. Equipment user manual recommends that normalization of the detectors efficiency be made as often as possible and always whenever there are hardware or software parameters changes - included, but not limited to channels parameters adjustments, electronic cards replacements, channels activation or inactivation or software update. This work evaluates the normalization effects on the image quality parameters. PET image acquisition were performed using recommended parameters by the NEMA NU 4-2008 standards. Image was reconstructed in different ways using different normalization files. The tests performed indicated that the image quality parameters do not vary significantly with different normalization data. Therefore, a daily routine of normalizations is not justified, suggesting a periodical frequency of one month or more for this procedure.