A current differential protection criterion based on amplitude and phase difference of fault current

Author(s):  
Linlin Zhang ◽  
Wei Cong ◽  
Tangsheng Xun ◽  
Yong Bai
2020 ◽  
Vol 12 (4) ◽  
pp. 1436
Author(s):  
Yingyu Liang ◽  
Wulin Li ◽  
Guanjun Xu

The amplitude and phase angle of the fault current in photovoltaic power plants (PVPPs) are significantly influenced by the control system of the grid-connected inverters, unlike in a conventional synchronous source. Hence, PVPPs may adversely affect the performance of the current differential protection designed for synchronous sources-based power grids. In order to study the performance problem of current differential protection on AC transmission lines, an analytical expression of the fault current in the PVPPs was deduced, and the fault current characteristic was extensively analyzed. Based on this analysis, the ratio of differential current over restraint current was initially derived in this study; this ratio is observed to be affected by the control system parameters, power grid system parameters, fault resistance, and fault types. Moreover, the dynamic characteristics of this ratio can be clearly observed based on a three-dimensional diagram. Furthermore, the operating performance of the current differential protection was analyzed under different influencing factors. The mathematical analysis presents that the amplitude ratio of the fault current on both sides of the line is larger than nine and that current differential protection will operate reliably in any case. Meanwhile, the theoretical analysis and simulation results show that the current phase angle difference may become an obtuse angle in case of an ungrounded fault, which will cause inaccurate operation of the current differential protection. The results of this study will provide guidance for the engineering application of current differential protection in case the PVPPs are connected to a power grid.


2009 ◽  
Vol 2009 ◽  
pp. 1-5 ◽  
Author(s):  
Jiun-Wei Horng

This paper describes a current-mode third-order quadrature oscillator based on current differencing transconductance amplifiers (CDTAs). Outputs of two current-mode sinusoids with90°phase difference are available in the quadrature oscillator circuit. The oscillation condition and oscillation frequency are orthogonal controllable. The proposed circuit employs only grounded capacitors and is ideal for integration. Simulation results are included to confirm the theoretical analysis.


2014 ◽  
Vol 556-562 ◽  
pp. 1959-1963
Author(s):  
Si Ming Wei ◽  
Yi Gong Zhang ◽  
Huan Liu ◽  
Zhi Qiang Dai ◽  
Xiao Du

It is great significance for development of MTDC (Multi-terminal HVDC) to build DC transmission and distribution grids. However, the relatively low impedance in DC grids makes the fault penetration much faster and deeper .Consequently, fast and reliable DC circuit breaker is needed to isolate faults. Breaking time and other parameters are important for a breaker to achieve its goals. This paper presents a DC circuit breaker with a current-limiting inductance and gets the rising and falling characteristics of fault current. Based on the characteristics, a design method of breaking time sequence will be given, as well as the calculation of current-limiting inductance and the selection principles of arresters. A 10kV DC distribution grid is modeled and simulated by PSCAD/EMTDC to verify that the method can meet the requirements of breaking fault current quickly and reliably.


Sign in / Sign up

Export Citation Format

Share Document