current differential protection
Recently Published Documents


TOTAL DOCUMENTS

152
(FIVE YEARS 36)

H-INDEX

13
(FIVE YEARS 1)

2021 ◽  
Vol 2113 (1) ◽  
pp. 012053
Author(s):  
Yu Qin ◽  
Minghao Wen ◽  
Yu Bai ◽  
Yuxi Wang ◽  
Zeya Fang

Abstract The present current differential protection for MMC-HVDC transmission lines has absolute selectivity and powerful ability to withstand high transition resistance, while it is easily affected by distributed capacitive current and data synchronization error. To solve the problem above, this article proposes a novel current differential protection scheme. The distributed capacitive current can be calculated by integrating the linear voltage distribution in real-time. Thus, the differential value of the midpoint currents of DC line, which are calculated based on the low-pass filtered measure voltages and currents on both sides, can be adopted to identify the fault. Besides, the data synchronization error can be eliminated based on the waveform matching of the calculated midpoint currents. This novel current differential protection has excellent performance and can solve the problems of traditional current differential protection for HVDC lines.


2021 ◽  
Vol 257 ◽  
pp. 01016
Author(s):  
Pengfei Shao ◽  
Yu Li ◽  
Ruiming Fang ◽  
Xinghua Guo

Half-wavelength AC transmission line has the characteristics of long transmission distance and high voltage level, and its fault characteristics are significantly different from conventional transmission line. In order to reduce the interference of distributed capacitive current on half-wavelength AC transmission line on the calculation of current differential protection, this paper proposes a new current differential protection scheme based on Bergeron model. In order to solve the problem of small differential current located at the midpoint when a short circuit fault occurs, a solution using different methods to calculate setting value in different areas is proposed. The protection can move quickly near the terminal and delay to act in the middle area. After simulation and verification on the PSCAD experimental platform, it is found that when there is a fault at both terminals of the line, the protection can quickly operate in about 10 ms; when fault occurs in the middle area, the protection can delay its operation. The experimental results show that the various actions and performance of the protection device can meet the requirements of safe operation of half-wavelength transmission line.


Sign in / Sign up

Export Citation Format

Share Document