The Research on Voltage Regulation Methods in Central China Power Grid to Suit Large-Power Transmitted through UHV Project

Author(s):  
Xiaojie Pan ◽  
Hong Zhou ◽  
Yong Huang ◽  
Dichen Liu
Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3489
Author(s):  
Huabo Shi ◽  
Xinwei Sun ◽  
Gang Chen ◽  
Hua Zhang ◽  
Yonghong Tang ◽  
...  

The central Tibet AC interconnection project (CTAIP), which connects the Tibet power grid and the Sichuan power grid through a long distance transmission line of more than 1400 km, has a significant problem of voltage regulation. In order to improve the voltage regulation performance, six sets of ±60 Mvar static VAR compensators (SVC) were installed in the CTAIP. However, the SVCs may lead to electromagnetic oscillation below 50 Hz while improving voltage regulation capability. In this paper, the electromagnetic oscillation modes and the sensitivity of control parameters of SVC are analyzed. Then, the characteristics and influencing factors of the oscillation are discussed. It was found that there is an inherent electromagnetic oscillation mode below 50 Hz in the ultra-long distance transmission system. The employ of SVCs weaken the damping of this mode. Large proportional gain and integral gain (PI) parameters of SVCs can improve the voltage regulation performance, but weaken the electromagnetic oscillation mode damping. Therefore, a suppression method based on SVC PI parameters optimization is proposed to damp the oscillation. The essential of this method is to use the rising time of voltage response and setting time of SVCs as performance indicators of voltage regulation, and take the damping level of the electromagnetic oscillation mode as the performance index of SVC electromagnetic oscillation suppression ability. Combining the two indicators to form a comprehensive optimization index function, an intelligent optimization algorithm is applied. The process of SVC parameter optimization and the steps of multi-SVC parameter optimization in large power grids is proposed. Finally, PSCAD and real-time digital simulation (RTDS) simulation results verified the correctness of the proposed method. The optimization strategy was applied to CTAIP. The artificial grounding short circuit experimental results proved the effectiveness of the proposed strategy.


Author(s):  
Xiaotong Zhang ◽  
Shenghui Li ◽  
Xue Bai ◽  
Xiaole Luo ◽  
Ce Zhang ◽  
...  

2016 ◽  
Vol 16 (6) ◽  
pp. 220-231
Author(s):  
Hong Kun Wang ◽  
Shou Xiang Wang ◽  
Jing Nie

Abstract With the formation of China’s large power grid, the security of the network is particularly important. The contaminant flashover of insulators has a serious impact on the operation safety of a high voltage power network. In this paper, the acoustic signals’ characteristics of the contaminant insulators flashover are analyzed, and, as a result, the correlation between the acoustic signal and the contaminant insulator flashover is established. To experiment with contaminant insulator for three different Equivalent Salt Deposit Densities (ESDD), acoustic signals were collected separately. Then, the contaminant insulators’ acoustic signals of flashover were analyzed by wavelet packet. The characteristics of the signals were obtained, and they can be judged for contaminant flashover warning.


2017 ◽  
Vol 2017 (13) ◽  
pp. 1862-1866 ◽  
Author(s):  
Shengbo Jiang ◽  
Xueli Pan ◽  
Yi Xiao ◽  
Qiangming Zhou ◽  
Miao Li ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document