Analysis of Frequency Response of Transformer with Inter-Turn Short Circuit Fault due to Transients

Author(s):  
Bibhav Das ◽  
Sathyamoorthy Dhayalan ◽  
Enukonda Venkateshwar Reddy ◽  
Birender Singh Thind ◽  
C. C. Reddy
Author(s):  
Nurul Farahwahida Md Yasid ◽  
A. A. Alawady ◽  
M. F. M. Yousof ◽  
S. Al-Ameri ◽  
M. S. Kamarudin

Sweep frequency response analysis (SFRA) is a reliable method for detection and diagnosis of faults in the active part of transformers. However, although SFRA is widely employed, the interpretation of SFRA signature is still a challenge and require experts to analyse them. This is due to lack of guideline and standard for SFRA signature interpretation and clarification. This paper presents the interpretation of SFRA signature by classification and quantification on inter-turn short circuit fault on the transformer winding. The short-circuited turns fault on HV winding phase “A” was practically simulated on three different units of three-phase transformers. The results of simulated fault are presented and discussed. A conclusion was drawn which provides the interpretation of the SFRA response due to inter-turn short circuit fault case by using a statistical indicator which is NCEPRI algorithm.


Author(s):  
N. F. M. Yasid ◽  
A. A. Alawady ◽  
M. F. M. Yousof ◽  
M. A. Talib ◽  
M. S. Kamarudin

Different techniques for monitoring the transformer condition are continuously discussed. This is due to the fact that transformers are one of the most expensive components in the power system network. Not to mention the cost to fix any failure occurred in the transformer that have becoming more expensive nowadays. Frequency response analysis (FRA) is found to be the best method to monitor the transformer reliability. This paper presents a continuation of study presented in previous paper [1]. The study performed a laboratory test to show that the response of a normal winding phase A can be affected by short circuit fault which occurred at LV winding phase a, b, and c. To further investigate, current paper performed FRA measurement and applied fault on all phases. The same procedure is repeated on a distribution transformer to verify the findings. This is to examine the effect of fault at winding of other phases to the response of measured phase.


2019 ◽  
Vol 9 ◽  
pp. 22-29
Author(s):  
Yury Ya. LYAMETS ◽  
◽  
Mikhail V. MARTYNOV ◽  
Alexander N. MASLOV ◽  
◽  
...  

2019 ◽  
Vol 11 ◽  
pp. 33-39
Author(s):  
Yury Ya. LYAMETS ◽  
◽  
Mikhail V. MARTYNOV ◽  
Alexander N. MASLOV ◽  
◽  
...  

2019 ◽  
Vol 5 (5) ◽  
pp. 19-23
Author(s):  
Leonid A. GERMAN ◽  
◽  
Alexandr S. SEREBRYAKOV ◽  
Aleksey B. LOSKUTOV ◽  
Vladimir L. OSOKIN ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document