scholarly journals Wind farm grounding system analysis

Author(s):  
Massood Keshavarz Siahpoosh ◽  
Li Li ◽  
David G. Dorrell
2013 ◽  
Vol 448-453 ◽  
pp. 2535-2539
Author(s):  
Jun Cheng ◽  
Qiang Yang ◽  
Tao Zhu ◽  
Ai Meng Wang ◽  
Xue Feng Hu ◽  
...  

With the scale of the wind farm growing fast, its impact on the power system has become increasingly apparent. So the research has a significant meaning on the characteristics of dynamic stability of the power system which contains wind farms, and the stable operation of the large area interconnected power grid. In this paper it realized the application of the double-fed wind turbine grid model by using power system analysis software PSD-BPA. The analysis of the generator power Angle curve which indicate the state after the failure of N-1 shows as follows: with the wind farms integration on the grid, the damping ratio is decreased slightly but little change after the system failure of N-1, which is still live up to the standard of grid stability.


2013 ◽  
Vol 433-435 ◽  
pp. 1320-1324
Author(s):  
Wei Zheng ◽  
Shi Qun Li ◽  
Yong Zhi ◽  
Run Qing Bai ◽  
Chen Liang ◽  
...  

Recently, the static synchronous compensator (STATCOM) device has been installed in Jiuquan wind farm in Gansu Province. To study its ability to support voltage, this paper presents a study of the mathematical model of the steady state and transient state of STATCOM and then uses the power system analysis software package (PSASP) to establish a user-defined model of STATCOM. In addition, the model is added into the power system example (CEPRI 7). After that, the power flow calculation and transient stability calculation are carried out to simulate and analyze. At last the STATCOM device is field tested in Jiuquan wind power base. Test results verify that STATCOM effectively supports the grid voltage.


2011 ◽  
Vol 36 (7) ◽  
pp. 2004-2010 ◽  
Author(s):  
Olatz Ukar ◽  
Inmaculada Zamora

2013 ◽  
Vol 765-767 ◽  
pp. 2579-2585
Author(s):  
Min Jing Yang ◽  
Yan Li ◽  
Jin Yu Wen ◽  
Chun Fang Liu ◽  
Min Jie Zhu ◽  
...  

The high penetration of doubly-fed induction generators (DFIGs) entails a change in dynamics and operational characteristics of the power system, thus this paper investigates the small signal stability of the large-scale wind farm with DFIGs. The GE 1.5MW DFIG is modeled in power system analysis software package (PSASP), and a large-scale wind farm with DFIGs is established. Then, the two-area test system with four generators is applied to assess the effect of the large wind farm on power system inter-area oscillatory mode in which the penetration and the installation site of the wind farm are considered. Finally, the simulation results indicate that abundant penetration of DFIG-based wind power will improve the inter-area oscillatory, and the integration of wind farms with DFIGs in the receiving area makes the inter-area mode highly damped.


2014 ◽  
Vol 584-586 ◽  
pp. 2695-2699
Author(s):  
Wen Bo Yu ◽  
Xiao Lin Luo ◽  
Bing Chen ◽  
Wen Xiang Wang

Wind power has become one of the most potential and vital green energy sources. Location of the wind farm has a better wind resource,and it is also relatively open. Lightning accident in the wind farm happened occasionally, in order to avoid the situation, which impulse current damages the wind turbine, in the accident, lightning protection grounding system of wind turbine is essential .In this paper, according to the experience of Dongshan wind farm project , the method of how to design the wind turbines and booster station grounding grid as required, the calculation of ground resistance and specific measures to reduce grounding resistance of wind turbine grounding device are discussed.


2015 ◽  
Vol 51 (6) ◽  
pp. 5086-5094 ◽  
Author(s):  
Jordanco Angelov ◽  
Jovica Vuletic ◽  
Risto Ackovski ◽  
Mirko Todorovski

Sign in / Sign up

Export Citation Format

Share Document