Grounding System Analysis: Microwave Engineering Approach

Author(s):  
Babak Honarbakhsh
2015 ◽  
Vol 51 (6) ◽  
pp. 5086-5094 ◽  
Author(s):  
Jordanco Angelov ◽  
Jovica Vuletic ◽  
Risto Ackovski ◽  
Mirko Todorovski

2012 ◽  
Vol 516-517 ◽  
pp. 1359-1366 ◽  
Author(s):  
Ye Xu Li ◽  
Farid Paul Dawalibi ◽  
Jin Xi Ma

Grounding system analysis and design considerations for large hydroelectric power plant are analyzed and discussed in this paper. The main work that has been carried out includes: constructing adequate soil structures and analyzing the effects of the finite heterogeneous soil structure, the modeled river length and the water reservoir levels; conducting accurate fault current distribution calculations and studying the influence of circulating current on the touch and step voltages. The paper discusses the design of the grounding system and its safety performance while considering the impact of the circulating current and inductive coupling from cables and long parallel conductors inside the plant. Two practical examples have been provided in this paper. Furthermore, the paper demonstrates the effectiveness of using heterogeneous finite soil volumes to analyze large hydroelectric power stations and confirms that accurate grounding software packages are required to account for large circulating currents within the ground conductors and strong inductive coupling that exists between metallic elements within the substation. The results and discussions presented here can be used as a reference for engineers to analyze extensive grounding systems and to design appropriate grounding systems for large hydroelectric power plant.


1994 ◽  
Vol 9 (4) ◽  
pp. 1838-1849 ◽  
Author(s):  
F.E. Mentre ◽  
L. Grcev

1993 ◽  
Vol 8 (1) ◽  
pp. 13-23 ◽  
Author(s):  
A.P.S. Melipoulos ◽  
F. Xia ◽  
E.B. Joy ◽  
G.J. Cokkinides

2021 ◽  
Vol 11 (16) ◽  
pp. 7468
Author(s):  
Navinesshani Permal ◽  
Miszaina Osman ◽  
Azrul Mohd Ariffin ◽  
Mohd Zainal Abidin Ab Kadir

Designing an effective grounding system for AC substations needs predetermination of ground resistance and ground potential distribution caused by fault current’s presence in the ground. Therefore, it is necessary to have a suitable grounding grid structure in the soil properties in which the grid is buried. Though the soil composition where the grounding grid is located is typically non-homogeneous, the soil is often presumed to be homogeneous due to the complexities of grounding system analysis in non-homogeneous soil. This assumption will lead to inaccuracies in the computation of ground resistance and ground potentials. Although extensive research has been done on non-homogeneous soil structure, comprehensive literature on grounding system performance in non-homogeneous soil is yet to be reviewed. Thus, this paper reviews the effect of non-homogeneous soil on the grounding system, with different soil characteristics in horizontal and vertical two-layer soil structure and the horizontal three-layer soil structure. In addition, the effect of design parameters on the grounding performance in non-homogeneous soil conditions for non-transient fault conditions is also studied. The significance of this study is that it provides a comprehensive review of grounding performance as grounding design changes and their effects as soil layers and their corresponding features change. This knowledge will be useful in developing safe grounding designs in non-homogeneous soil.