A New Research on Intelligent Protection and Positioning Integration Method of Single Phase Grounding Fault in Small Current Grounding System

Author(s):  
Cao Jingjin ◽  
Qin Lijun ◽  
Li Yongxiang ◽  
Jin Tao ◽  
Yuan Hui ◽  
...  
2019 ◽  
Vol 1303 ◽  
pp. 012131
Author(s):  
Jinwei Fu ◽  
Changkai Shi ◽  
Wenbo Fan ◽  
Shilei Guan

2012 ◽  
Vol 614-615 ◽  
pp. 1833-1840
Author(s):  
Li Li

With the rapid development of power network automation, the detection of the default single-phase grounding fault line in small current neutral grounding system has became a hot spot in research of power network system. Generally, power network neutral point is not grounded or grounded through arc-suppression coil grounding. When single phase grounding fault occurs, the power network system is named as small current grounding system since the grounding short-circuit is small due to a low-impedance short circuit.


2014 ◽  
Vol 492 ◽  
pp. 407-411 ◽  
Author(s):  
Yin Tao ◽  
Yu Juan

Single-phase ground fault line selection problem has never been satisfactorily resolved in small current neutral grounding system in china. According to such a situation and combining theoretical analysis and simulation research with reports published in literature, existing faulty line selection technologies are generalized, and working principles, application conditions and existing defects of these technologies are analyzed, meanwhile the feasible improvement of these technologies and the up-to-date research achievements, and deficiencies of applications in this field are summarized. Finally, the development trend of faulty line selection technology for small-current neutral grounding system is pointed out.


2014 ◽  
Vol 620 ◽  
pp. 394-397
Author(s):  
Xiang Dong Zhao ◽  
Feng Zhen Liu ◽  
Ye Tian

While the system is equipped with Petersen coil caused by the switching operation can prevent a different period , single-phase disconnection and other factors neutral point displacement , so that the neutral point voltage is too high, the threat of insulation safety equipment . Also in the normal operation of the power grid , but also effectively prevent resonance over-voltage , prevent system damage caused thereby , better protection of system security , stability, and high-quality operation. Summary of small current grounding system after the formation of arc suppression coil compensation compensation network system , in order to better prevent arc short-circuiting the system of single phase , which is to ensure security of supply , improve reliability and power quality .In the paper, small current grounding system Petersen coil with the compensation adjustment is carried out and some analysis, study and research is done in order to improve the operating personnel awareness and emphasis on small current grounding system , and better ensure the safety of the small current grounding system , stable operation.


2014 ◽  
Vol 513-517 ◽  
pp. 3552-3555
Author(s):  
Xiang Gao ◽  
Lu Wang

For the problem of single-phase ground fault line selection of small current grounding system, in this paper, according to the wavelet theory advantage processing capabilities of transient mutation signal ,line selection criterion based on wavelet transform modulus maximum principle of singularity detection is proposed . By analyzing the single-phase ground fault waveform of small current grounding system in the neutral point not effective grounding system, steady state and transient characteristics of fault occurs is obtained, building bus with three outlets of 10KV small current grounding system simulation model by using MATLAB software, and verifying the validity though a large number of simulation experiments on the method.


Sign in / Sign up

Export Citation Format

Share Document