Transient Overvoltage Analysis of Wind Farm PCC Caused by HVDC Commutation Failure under Different Faults

Author(s):  
Lin Pei ◽  
Tong Wang ◽  
Jiaming Wang ◽  
Zengping Wang
2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Shuanbao Niu ◽  
Xianbo Ke ◽  
Qiang Shen ◽  
Chao Huo ◽  
Ning Chen ◽  
...  

The development of smart power systems in Industry 4.0 will bring people better quality electrical energy. The photovoltaic power generation system in the smart grid for Industry 4.0 is also the focus of development. The rapid development of photovoltaic power generation systems will bring people cleaner and greener energy. However, it will cause the transient overvoltage phenomenon near the DC sending terminal when the large-scale photovoltaic plant is connected to the power grid, further bringing about a profound impact on the power grid and its security and stability. In this paper, it is proposed that the rise of transient overvoltage at the photovoltaic terminal is caused by three main factors including the reactive power surplus of DC commutation failure, the weak power grid at the sending terminal, and the control characteristics of the photovoltaic plant. Then, the coordinated control strategy of transient overvoltage is proposed, and the overvoltage control strategy of the DC transmission terminal and the photovoltaic power plant control strategy are, respectively, optimized. Finally, the influence parameters of overvoltage are analysed and the corresponding photovoltaic strategy is presented. The optimization results of photovoltaic parameters and the proposed strategies of photovoltaic power generation can effectively restrain the voltage or frequency fluctuation and power oscillation caused by HVDC commutation failure. This study promotes the development of the photovoltaic power generation system in the intelligent power system of industry 4.0.


Author(s):  
Zmnako Mohammed ◽  
Hashim Hizam ◽  
Chandima Gomes

<p>Study the impacts of lightning-induced transient overvoltage on a hybrid PV-Wind system has been addressed in this work. Overvoltage that is generated due to lightning stroke travels along the system where it can be very harmful to the expensive equipment of the system such as PV models, inverters, charge controllers, batteries, transformers, generator. etc. The simulation model of a system has been completed by using PSCAD/EMTDC software. The system comprises of 2 MW PV farm, battery system, 2.1 MW wind farm and loads which are all connected to the common AC bus and then to the utility grid through an interfacing transformer. Lightning current is generated by using the double exponential function, From the simulation results, when the lightning current is injected to the AC and DC sides of PV system, the transient current and voltage have appeared at different points of the hybrid system. The results were obtained for 8/20 μs and 10/350 μs standards lightning waveforms with current magnitude of 100 kA.</p>


Sign in / Sign up

Export Citation Format

Share Document