Optoelectrokinetically-Enabled Signal Enhancement for a Bead-Based FRET Fluorescence Immunoassay

Author(s):  
Han-Sheng Chuang ◽  
Kuan-Chih Wang ◽  
Dar-Bin Hsieh ◽  
Yong Qing Fu
1994 ◽  
Author(s):  
Thomas F. Quantieri ◽  
Robert B. Dunn ◽  
Robert J. McAulay
Keyword(s):  

2019 ◽  
Vol 13 (1) ◽  
pp. 137-145 ◽  
Author(s):  
Tzonka Godjevargova ◽  
Zlatina Becheva ◽  
Yavor Ivanov ◽  
Andrey Tchorbanov

Objectives: Staphylococcus aureus is a Gram-positive microorganism. S. aureus can grow in various foods and cause food poisoning by secreting enterotoxins. The most common enterotoxins involved in food poisoning are staphylococcal enterotoxin A and staphylococcal enterotoxin B, but Staphylococcal Enterotoxin A (SEA) is predominant. The main types of food contaminated with SEs are meat and meat products, poultry and eggs, milk and dairy products. The aim of this study was to develop a rapid and sensitive fluorescence immunoassay for detection of staphylococcal enterotoxin A in milk. Methods: Monoclonal and polyclonal antibodies for SEA were produced and characterized. Competitive fluorescence immunoassay based on Magnetic Nanoparticles (MNPs) was performed and optimized. MNPs were used as a solid carrier of the antibodies. The first step of the assay was immunoreaction between the immobilized antibody onto MNPs and SEA in milk sample. Then the fluorescein-SEA conjugate was added to the sample. Thus, competitive immunoreaction between MNP-mAb/MNP-pAb with SEA and SEA-FITC was performed. These immuno-complexes were separated by a magnetic separator and the obtained supernatants were analyzed. The fluorescent signal from the excess of conjugated SEA was proportional to the SEA contained in the milk. The assay duration was only 30 min. Results: The fluorescence immunoassays performed with polyclonal antibody had linear ranges from 5 pg/mL to 100 ng/mL SEA in a buffer, and from 50 pg/mL to 50 ng/mL SEA in spiked milk samples. While the same assays performed with monoclonal antibody had linear ranges from 1 pg/mL to 20 ng/mL SEA in buffer, and from 10 pg/mL to 10 ng/mL SEA in spiked milk samples. The detection limits of the developed immunoassays performed in milk were: 48 pg/mL with polyclonal antibody and 9 pg/mL with monoclonal antibody. Conclusion: A rapid and sensitive fluorescence immunoassay based on magnetic nanoparticles with a polyclonal and monoclonal antibody for determination of staphylococcal enterotoxin A in milk was developed.


2021 ◽  
Vol 422 ◽  
pp. 129983
Author(s):  
Yi Li ◽  
Xiaoli Xin ◽  
Tingting Zhang ◽  
Weihua Li ◽  
Jiansheng Li ◽  
...  

2021 ◽  
pp. 126902
Author(s):  
L.A. Finney ◽  
J. Lin ◽  
P.J. Skrodzki ◽  
M. Burger ◽  
J. Nees ◽  
...  

RSC Advances ◽  
2021 ◽  
Vol 11 (44) ◽  
pp. 27541-27546
Author(s):  
Qingquan Zhang ◽  
Jiajia Li ◽  
Yuting Su ◽  
Xiaoyan Pan ◽  
Hongwei Gai

A contactless and ball-lens assisted sensitivity improvement method was present for the fluorescence or luminescence immunoassay in microchannel.


RSC Advances ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 517-524
Author(s):  
Chuanyong Li ◽  
Wanlin Sun ◽  
Lianrun Huang ◽  
Nana Sun ◽  
Xiude Hua ◽  
...  

The anti-thiamethoxam and anti-dextran monoclonal antibodies were prepared to develop a multicolor upconversion fluorescence immunoassay for the simultaneous determination of thiamethoxam (544 nm) and dextran (477 nm).


Sign in / Sign up

Export Citation Format

Share Document