Colorimetric Characterization of High Dynamic Range Liquid Crystal Displays and Its Application

2009 ◽  
Vol 5 (1) ◽  
pp. 40-45 ◽  
Author(s):  
Yu-Kuo Cheng ◽  
Han-Ping D. Shieh
2018 ◽  
Vol 26 (13) ◽  
pp. 16572 ◽  
Author(s):  
Guanjun Tan ◽  
Yuge Huang ◽  
Ming-Chun Li ◽  
Seok-Lyul Lee ◽  
Shin-Tson Wu

2017 ◽  
Vol 25 (3) ◽  
pp. 1973 ◽  
Author(s):  
Haiwei Chen ◽  
Ruidong Zhu ◽  
Ming-Chun Li ◽  
Seok-Lyul Lee ◽  
Shin-Tson Wu

Author(s):  
Tatsuya Iwasaki ◽  
Yuki Nakamura ◽  
Toshikazu Sumi ◽  
Katsufumi Ohmuro ◽  
Masaaki Suzuki ◽  
...  

2021 ◽  
Vol 14 (3) ◽  
pp. 2201-2217
Author(s):  
Juan C. Antuña-Sánchez ◽  
Roberto Román ◽  
Victoria E. Cachorro ◽  
Carlos Toledano ◽  
César López ◽  
...  

Abstract. All-sky cameras are frequently used to detect cloud cover; however, this work explores the use of these instruments for the more complex purpose of extracting relative sky radiances. An all-sky camera (SONA202-NF model) with three colour filters narrower than usual for this kind of cameras is configured to capture raw images at seven exposure times. A detailed camera characterization of the black level, readout noise, hot pixels and linear response is carried out. A methodology is proposed to obtain a linear high dynamic range (HDR) image and its uncertainty, which represents the relative sky radiance (in arbitrary units) maps at three effective wavelengths. The relative sky radiances are extracted from these maps and normalized by dividing every radiance of one channel by the sum of all radiances at this channel. Then, the normalized radiances are compared with the sky radiance measured at different sky points by a sun and sky photometer belonging to the Aerosol Robotic Network (AERONET). The camera radiances correlate with photometer ones except for scattering angles below 10∘, which is probably due to some light reflections on the fisheye lens and camera dome. Camera and photometer wavelengths are not coincident; hence, camera radiances are also compared with sky radiances simulated by a radiative transfer model at the same camera effective wavelengths. This comparison reveals an uncertainty on the normalized camera radiances of about 3.3 %, 4.3 % and 5.3 % for 467, 536 and 605 nm, respectively, if specific quality criteria are applied.


2016 ◽  
Vol 24 (10) ◽  
pp. 600-610
Author(s):  
Jian-qing Zhang ◽  
Fang Cai ◽  
Zhen Liu ◽  
Guang-yuan Wu ◽  
Ming Zhu

1995 ◽  
Vol 20 (18) ◽  
pp. 1889 ◽  
Author(s):  
A. Braun ◽  
D. Kopf ◽  
I. D. Jung ◽  
J. V. Rudd ◽  
H. Cheng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document