2019 ◽  
Vol 55 (9) ◽  
pp. 1-5
Author(s):  
Matthias K. Bucher ◽  
Thomas Franz ◽  
Michael Jaritz ◽  
Jasmin Smajic ◽  
Jens Tepper

2017 ◽  
Vol 20 (K3) ◽  
pp. 5-10
Author(s):  
Khoi Dinh Anh Pham

Although the standard Frequency Response Analysis (FRA) test has been approved as an efficient tool to diagnose mechanical failures in power transformers, the demand to interpret FRA traces in practical and physical way is still requested. That means physical electrical parameters of transformers should be determined reasonably based on real measurements and afterwards are applicable for the interpretation. For purpose of FRA interpretation in practical manner, electrical parameters of power transformers in a physical equivalent circuit should be determined. As a first step, the paper introduces a new approach in determining frequency dependent core impedances of a distribution transformer based on the combination of circuit analysis of a duality-based model, measurements of driving-point impedances and experimental formulas. From that, two important contributions can be drawn. Firstly, frequency dependent core impedances are ready as available components in the circuit for FRA interpretation in broad frequency range. Secondly, the core parameters could be useful indicators for detecting relevant failures in cases there is no more failure on transformer windings.


2017 ◽  
Vol 20 (K3) ◽  
pp. 11-17
Author(s):  
Khoi Dinh Anh Pham

For a practical Frequency Response Analysis (FRA) interpretation applicable to power transformers, frequency dependent electrical parameters of the core and windings in broad frequency range should be identified through non-destructive measurements. Since the core parameters are determined in Part I, electrical parameters of windings (resistances, capacitances) and leakage paths surrounding windings (leakage/zero-sequence impedances) of a distribution transformer will be discussed in this paper. Due to the fact that most parameters associated with the windings currently can only be measured at or around power frequency through diagnostic testing methods, the practical parameter-based FRA interpretation is not possible. To deal with this problem, the paper proposes a new approach based on the combination of different measured driving-point impedances and relevant analysis of the duality-based equivalent circuit in determining frequency dependent parameters associated with transformer windings. Results show that the physical FRA interpretation can be reasonable obtained for the test transformer in low and medium frequency range.


2000 ◽  
Vol 41 (4) ◽  
pp. 481-492
Author(s):  
Naohiko Takahashi ◽  
Morio Ito ◽  
Shuji Ishida ◽  
Takao Fujino ◽  
Mikiko Nakagawa ◽  
...  

2017 ◽  
Vol 137 (2) ◽  
pp. 147-153
Author(s):  
Akinori Hori ◽  
Hiroki Tanaka ◽  
Yuichiro Hayakawa ◽  
Hiroshi Shida ◽  
Keiji Kawahara ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document