A closed-loop selective harmonic compensation with capacitor voltage balancing control of cascaded multilevel inverter for high-power active power filters

Author(s):  
Chen Junling ◽  
Li Yaohua ◽  
Wang Ping ◽  
Yin Zhizhu ◽  
Dong Zuyi
2016 ◽  
Vol 6 (5) ◽  
pp. 1133-1138 ◽  
Author(s):  
T. Demirdelen ◽  
R. I. Kayaalp ◽  
M. Tumay

In recent years, shunt hybrid active power filters are being increasingly considered as a viable alternative to both passive filters and active power filters for compensating harmonics. In literature, their applications are restricted to balanced systems and low voltage applications and therefore not for industrial applications. This paper investigates the performance of a modular cascaded multilevel inverter based Shunt Hybrid Active Power Filter (SHAPF) for reactive power compensation and selective harmonics elimination under distorted/unbalanced grid voltage conditions in medium voltage levels. In the proposed control method, reactive power compensation is achieved successfully with a perceptible amount and the performance results of harmonic compensation are satisfactory. Theoretical analysis and simulation results are obtained from an actual industrial network model in PSCAD. The simulation results are presented for a proposed system in order to demonstrate that the harmonic compensation performance meets the IEEE-519 standard.


2020 ◽  
Vol 8 (5) ◽  
pp. 4952-4961

Majority of loads in use today are power electronics based non-linear devices. Despite being compact and providing low energy consumption these loads generate inherent harmonics. Harmonics have several adverse effects such as interference with the communication lines, incorrect meter readings, increased losses, increased heating of electrical and sensitive electronic equipment. Sophisticated power electronic converter based filters named as Shunt Active Power Filters (SAPF) are widely being employed that provide superior harmonic filtering capabilities. Basic objective of SAPF is to generate or absorb currents that compensate harmonic currents produced by non- linear loads. These currents should be opposite in phase but have equivalent magnitude as that of harmonic currents. As compared to Diode-Clamped and Flying capacitor multilevel inverters, Cascaded multilevel configuration is employed for many applications due to ease of control and simple structure. In this research paper, power quality in a three-phase threewire system is improved by reducing source side current harmonics produced by a non-linear load. Initially a three-level Cascaded multilevel inverter based SAPF is developed and its performance is analyzed by using advanced Adaptive Neuro Fuzzy Inference System (ANFIS) controller. DC link capacitor voltage and percentage Total Harmonic Distortion (%THD) in source currents is measured at PCC for balanced loading conditions and results are compared. In this paper, it is also proposed to incorporate multilevel inverter topology concepts by employing Five-Level and Seven-Level Cascaded Multilevel Inverters as VSI circuit for SAPF. Performance of these multilevel Shunt Active power filters is analyzed by ANFIS controller. Instantaneous Active-Reactive power theory is implemented to compute reference compensating currents for all Shunt Active power filter models. Phase Disposition type Pulse Width modulation is chosen for generating gate pulses for VSI circuits of all Cascaded multilevel inverter configurations. Three-level, Five-level and Seven-level Shunt active power filter models are developed and simulated using MATLAB/ Simulink and results are presented.


Electronics ◽  
2020 ◽  
Vol 9 (12) ◽  
pp. 2052
Author(s):  
Odair de Barros Junior ◽  
Thiago Silva Amorim ◽  
Daniel Carletti ◽  
Anselmo Frizera Neto ◽  
Lucas Frizera Encarnação

The increasing number of electronic loads has introduced several harmonics into the power system, leading to a growth in the importance of filters intended for their mitigation. Thus, it is important to have the knowledge to select operational limits of each new filter connected in the power grid. Likewise, obtaining these harmonics requires robust tracking systems that provide enough information for better filter selectivity. This paper proposes a selective harmonic active filter control based on Fourier linear combiner (FLC) algorithms for a three-phase electrical grid. The presented system is enabled to track each harmonic order and sequence components with great robustness, extracting positive, negative, and zero sequence information from each harmonic for further filter selectivity. It also proposes a new strategy to improve the FLC-based algorithms in tracking frequencies in power grid disturbances. Simulated results of the algorithm and a real-time simulation of a selective active power filter (SAPF) were presented, validating the performance in several scenarios.


Sign in / Sign up

Export Citation Format

Share Document