Modelling and fault diagnosis of rotor inter turn short circuit fault in a doubly fed induction generator-based wind turbine

Author(s):  
Fatma Bouaziz ◽  
Olfa Awedni ◽  
Lotfi Krichen
2012 ◽  
Vol 512-515 ◽  
pp. 782-787
Author(s):  
Jia Jun Zhai ◽  
Bu Han Zhang ◽  
Kui Wang ◽  
Wen Shao ◽  
Cheng Xiong Mao

Doubly fed induction generator (DFIG) is now becoming one of most widely used wind turbines in global market for wind power generation, due to its outstanding advantages. However, the DFIG is sensitive to grid faults. The DFIG will have to be removed from the grid if there’s no protection appliance in it. Therefore, the crowbar protection is widely used in the world for improving the low voltage ride-through ability of wind turbines. This paper analysed the operating characteristics and short-circuit current of DFIG under symmetrical short-circuit fault with respect to different sags to grid voltage, which on the basis of DFIG wind turbine with crowbar protection. And the expressions of short-circuit current under symmetrical short-circuit fault for DFIG were derived. The effectiveness of the expression was simulated in PSCAD/EMTDC.


2021 ◽  
Vol 15 (1) ◽  
pp. 37-44
Author(s):  
Thai Hiep Le ◽  
◽  
Duong Hoang Phuc Tran

In this paper, the operating mode of a doubly fed induction generator (DFIG) wind turbine is studied in order to evaluate its fault ride-through and transient stability with a grid’s short circuit fault at near the wind power plant. Based on the structure of DFIG, external resistors are directly connected to rotor windings, then the generator operates as a wound rotor induction generator (WRIG) when there is a short circuit fault on the grid. According to the simulation results in Matlab, the active power is consumed on the crowbar resistor, causing the active power characteristic of generator is changed from high to low. As a result, the amount of excess mechanical energy is not much, so the generator be not accelerated significantly. These simulation results show that it is appropriate to use the crowbar resistor to change the power characteristic of the DFIG. Thanks to this change, the generator is still connected to the grid, stable operation both during and after a short circuit.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2471 ◽  
Author(s):  
Jing Li ◽  
Tao Zheng ◽  
Zengping Wang

An accurate calculation of short-circuit current (SCC) is very important for relay protection setting and optimization design of electrical equipment. The short-circuit current for a doubly-fed induction generator wind turbine (DFIG-WT) under excitation regulation of a converter contains the stator current and grid-side converter (GSC) current. The transient characteristics of GSC current are controlled by double closed-loops of the converter and influenced by fluctuations of direct current (DC) bus voltage, which is characterized as high order, multiple variables, and strong coupling, resulting in great difficulty with analysis. Existing studies are mainly focused on the stator current, neglecting or only considering the steady-state short-circuit current of GSC, resulting in errors in the short-circuit calculation of DFIG-WT. This paper constructs a DFIG-WT total current analytical model involving GSC current. Based on Fourier decomposition of switch functions and the frequency domain analytical method, the fluctuation of DC bus voltage is considered and described in detail. With the proposed DFIG-WT short-circuit current analytical model, the generation mechanism and evolution law of harmonic components are revealed quantitatively, especially the second harmonic component, which has a great influence on transformer protection. The accuracies of the theoretical analysis and mathematical model are verified by comparing calculation results with simulation results and low-voltage ride-through (LVRT) field test data of a real DFIG.


2017 ◽  
Vol 2 (2) ◽  
Author(s):  
N. Boumalha ◽  
R. Hachelef ◽  
D. Kouchih ◽  
M. Tadjine ◽  
M.S. Boucherit

This paper describes a Fault Tolerant Control (FTC) of a doubly-fed induction generator (DFIG) based wind turbine model suitable for the simulation of this generator in the mode faulty mode. The dynamic model of a DFIG with stator inter-turn short circuit fault is proposed. A model (abc) is developed, which can represent both the healthy and faulty conditions. The DFIG is directly connected to the grid whereas the rotor winding is fed by back-to-back PWM converters .the Control schemes for active and reactive power regulation are designed firstly. Under different wind speed, maximum power point tracing (MPPT) control is implemented to ensure the optimum active power output. The numerical simulation developed in Matlab/Simulink studies the effects of stator inter-turn short-circuit in the DFIG. Afterward, the application of Approach technique of Adaptive Obs