RPM-Based Approach to Extract Power System Steady State and Small Signal Stability Information From the Time-Domain Simulation

2011 ◽  
Vol 26 (1) ◽  
pp. 261-269 ◽  
Author(s):  
Menghua Fan ◽  
Venkataramana Ajjarapu ◽  
Chengshan Wang ◽  
Dan Wang ◽  
Cheng Luo
Author(s):  
Ohnmar Swe

This paper presents the small signal stability of multi-machine power system over the 58-Bus, 26-Machine, Yangon Distribution Network and is validated with MATLAB software under various disturbance conditions. Time-domain solution analysis is employed to determine the small signal dynamic behavior of test system. Transtability model is used to perform time-domain simulation in SIMULINK. The simulation is carried out for normal condition, reference voltage of regulator (Vref) disturbance, mechanical torque (Tm)disturbance and network (fault) disturbance and the conditions of change in center of inertia for rotor angle (delta COI),  slip for center of inertia (slip COI), field current and mechanical torque are observed. According to the simulation results, perturbation of Vref shows only instability on the system. But ramping of Tm and network disturbance can cause large disturbance on the system and unstable conditions can be observed.


This paper focuses on methodologies for calculation and examination of oscillatory security of interconnected power system network against constant disturbances. For instance, voltage soundness, transient dependability and oscillatory behaviors are also the measure of power system stability, which must be evaluated. For that proposed strategies based on proportional integral and fuzzy logic controlling techniques are implemented. The integral controller-based technique provides the zero steady-state error and with adequate damping, time to reach steady state can be reduced, on the cost of oscillation in frequency and tie-line power. On the contrary, fuzzy logic has demonstrated that strategies of computational intelligence can alleviate the quick appraisal of oscillatory solidness with less time to reach steady state. Furthermore, Eigenvalues are constructed for small signal stability analysis, utilizing a parallel variation of Arnoldi technique, reducing the time essential for calculation of vast Multi-Area power frameworks. For exhibit purposes, models have been composed utilizing MATLAB/SIMULINK and with the assistance of the fuzzy logic.


2009 ◽  
Vol 129 (11) ◽  
pp. 1290-1298
Author(s):  
Hiroyuki Ishikawa ◽  
Yasuyuki Shirai ◽  
Tanzo Nitta ◽  
Katsuhiko Shibata

Sign in / Sign up

Export Citation Format

Share Document