Cementation of the highly cross‐linked polyethylene liner into a well‐fixed acetabular shell to treat patients with recurrent dislocation after total hip arthroplasty

2020 ◽  
Author(s):  
Pai‐Han Wang ◽  
Shang‐Wen Tsai ◽  
Cheng‐Fong Chen ◽  
Po‐Kuei Wu ◽  
Chao‐Ming Chen ◽  
...  
2004 ◽  
Vol 39 (7) ◽  
pp. 766
Author(s):  
Byung Woo Min ◽  
Ki Cheol Bae ◽  
Kyung Jae Lee ◽  
Sung Won Sohn ◽  
Chul Hyung Kang

2019 ◽  
Vol 101 (5) ◽  
pp. 421-428 ◽  
Author(s):  
Stephen M. Petis ◽  
Bernd Kubista ◽  
Robert U. Hartzler ◽  
Matthew P. Abdel ◽  
Daniel J. Berry

2002 ◽  
Vol 12 (3) ◽  
pp. 303-307
Author(s):  
M.D.A. Fletcher ◽  
J.C.J. Webb ◽  
T. Maung

Dislocation is a serious complication of total hip arthroplasty occurring in up to 9% of cases. Recurrent dislocation accounts for 4% of revisions in the Swedish Hip Arthroplasty Study. Soft tissue balancing is one of the factors, independent of the surgical approach used, that is involved in producing a stable total hip replacement. We describe a proximal referencing system for use with the Charnley low friction arthrosplasty (LFA), which optimises this factor. The dislocation rate, using this method, is 0.3% (in 333 cases performed by a single surgeon over a 5 year period). This system should prove valuable to orthopaedic surgeons in training, ensuring they achieve correct soft tissue balance in total hip arthroplasty.


2019 ◽  
Vol 101-B (6_Supple_B) ◽  
pp. 123-126 ◽  
Author(s):  
M. El-Husseiny ◽  
B. Masri ◽  
C. Duncan ◽  
D. S. Garbuz

AimsWe investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores.Patients and MethodsWe retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications.ResultsAt ten years, the Kaplan–Meier survivorship for dislocation was 95.6% (95% confidence interval (CI) 90 to 98), with 101 patients at risk. At 20 years, the survivorship for dislocation was 90.6% (95% CI 81.0 to 95.5), with one patient at risk. Eight patients (7.2%) had a dislocation of their constrained liners. At ten years, the survival to any event was 89.4% (95% CI 82 to 93.8), with 96 patients at risk. At 20 years, the survival to any event was 82.5% (95% CI 71.9 to 89.3), with one patient at risk. Five hips (4.4%) had deep infection. Two patients (1.8%) developed dissociated constraining rings with pain but without dislocation, which required re-operation. Two patients (1.8%) had periprosthetic femoral fractures, without dislocation, that were treated by revision stems along with exchange of the well-functioning constrained liners.ConclusionConstrained tripolar liners used at revision hip arthroplasty provided favourable results in the long term for treatment of recurrent dislocation and for patients at high risk of dislocation. Cite this article: Bone Joint J 2019;101-B(6 Supple B):123–126.


2019 ◽  
pp. 112070001987361 ◽  
Author(s):  
Jesús Moreta ◽  
Iker Uriarte ◽  
Xabier Foruria ◽  
Ioar Urra ◽  
Urko Aguirre ◽  
...  

Background: Cementation of polyethylene liners into well-fixed cementless metal shells has become an option during revision total hip arthroplasty (THA). We report the results of cementing a dual-mobility (DM) component into a stable acetabular shell in high-risk patients undergoing revision THA. Methods: A single-centre series of 10 patients undergoing revision THA with a DM cup cemented into an existing well-fixed shell between 2012 and 2016 were retrospectively reviewed. Failure due to aseptic loosening or instability and implant survival at last follow-up were analysed. The average age was 79.2 years and mean follow-up was 3.5 years. Indications were recurrent hip dislocation in 8 cases and intraoperative instability with moderate abductor insufficiency in 2 cases. In cases with recurrent dislocation, the aetiology of instability was classified by Wera type. Results: At the latest follow-up, Harris Hip Scores had improved from 49.3 preoperatively to 71.3 postoperatively ( p = 0.098). In the 8 patients with recurrent dislocation, 4 cases (50%) had an unclear aetiology (Wera type 6), 2 (25%) abductor deficiency (Wera type 3) and 2 (25%) late polyethylene wear (type 5). Postoperative recurrent dislocation occurred in 1 hip (10%). No cases of intraprosthetic dislocation, aseptic loosening of the previous shell or dissociation at the cement-cup interface were identified. Conclusion: Although the follow-up of this series is short, cementation of a DM cup into a previous well-fixed socket seems to be a viable option to treat and prevent instability after revision THA, without providing constraint at the cement-cup interface.


Sign in / Sign up

Export Citation Format

Share Document