Dual mobility cups for recurrent dislocation of total hip arthroplasty

Author(s):  
Afshin Taheriazam
2018 ◽  
Vol 43 (10) ◽  
pp. 2245-2251 ◽  
Author(s):  
Chahine Assi ◽  
Jacques Caton ◽  
Wissam Fawaz ◽  
Camille Samaha ◽  
Kaissar Yammine

2019 ◽  
pp. 112070001987361 ◽  
Author(s):  
Jesús Moreta ◽  
Iker Uriarte ◽  
Xabier Foruria ◽  
Ioar Urra ◽  
Urko Aguirre ◽  
...  

Background: Cementation of polyethylene liners into well-fixed cementless metal shells has become an option during revision total hip arthroplasty (THA). We report the results of cementing a dual-mobility (DM) component into a stable acetabular shell in high-risk patients undergoing revision THA. Methods: A single-centre series of 10 patients undergoing revision THA with a DM cup cemented into an existing well-fixed shell between 2012 and 2016 were retrospectively reviewed. Failure due to aseptic loosening or instability and implant survival at last follow-up were analysed. The average age was 79.2 years and mean follow-up was 3.5 years. Indications were recurrent hip dislocation in 8 cases and intraoperative instability with moderate abductor insufficiency in 2 cases. In cases with recurrent dislocation, the aetiology of instability was classified by Wera type. Results: At the latest follow-up, Harris Hip Scores had improved from 49.3 preoperatively to 71.3 postoperatively ( p = 0.098). In the 8 patients with recurrent dislocation, 4 cases (50%) had an unclear aetiology (Wera type 6), 2 (25%) abductor deficiency (Wera type 3) and 2 (25%) late polyethylene wear (type 5). Postoperative recurrent dislocation occurred in 1 hip (10%). No cases of intraprosthetic dislocation, aseptic loosening of the previous shell or dissociation at the cement-cup interface were identified. Conclusion: Although the follow-up of this series is short, cementation of a DM cup into a previous well-fixed socket seems to be a viable option to treat and prevent instability after revision THA, without providing constraint at the cement-cup interface.


2012 ◽  
Vol 8 (3) ◽  
pp. 251-256 ◽  
Author(s):  
Patrice Mertl ◽  
Antoine Combes ◽  
Frédérique Leiber-Wackenheim ◽  
Michel Henri Fessy ◽  
Julien Girard ◽  
...  

2020 ◽  
Vol 04 (02) ◽  
pp. 090-093
Author(s):  
John M. Tarazi ◽  
Hytham S. Salem ◽  
Joseph O. Ehiorobo ◽  
Nipun Sodhi ◽  
Luke J. Garbarino ◽  
...  

AbstractModular dual mobility cups have been developed to potentially address postoperative hip instability, which can occur in nearly 20% of all revision total hip arthroplasty (THA) patients. By having a prosthetic construct that contains two points of articulation between the femoral head and liner and between the liner and shell, joint stability can be increased. The purpose of this study was to report on dual mobility cup survivorships, patient satisfaction outcomes, complications, and radiographic outcomes at a minimum 7-year follow-up. A high-volume academic surgeon performed a total of 143 consecutive dual mobility primary THAs on patients who had a minimum follow-up of 7 years (range, 7–8.5 years). The study cohort consisted of 77 females (54%) and 66 males (46%) who had a mean age of 65 years (range, 34–90 years). Aseptic, septic, and all-cause survivorship was determined by Kaplan-Meier analysis. Harris Hip Scores (HHS), postoperative complications, and radiographs were also assessed. No cup failures were observed. Overall, septic survivorship was 99.3% (95% confidence interval [CI]: 0.98–1.0) and all-cause survivorship was 98.6% (95% CI: 0.97–1.0). Two patients (1.4%) required revision surgery unrelated to the use of a modular dual mobility cup. Of these, one patient experienced femoral stem loosening and the other developed a periprosthetic infection that was treated with a two-stage revision. The mean total HHS was above 95 points at the most recent follow-up. Three patients (2.3%) experienced medical complications, including two deep vein thromboses and one for nonfatal pulmonary embolism. Radiographic evidence revealed incomplete seating of the metallic liner in one patient. Dual mobility cups were developed in an attempt to decrease the rate of instability following THA. The results from this study indicate that excellent clinical and patient-reported outcomes can be achieved at 7-year follow-up in patients who undergo THA with a dual mobility cup. Therefore, dual mobility cups appear to be an appropriate treatment option for primary THA.


2020 ◽  
Vol 35 (2) ◽  
pp. 513-519 ◽  
Author(s):  
Gary Sayac ◽  
Thomas Neri ◽  
Loïc Schneider ◽  
Rémi Philippot ◽  
Frédéric Farizon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document