Estimation of glomerular filtration rate in liver-transplanted children:Comparison of simplified procedures using 51Cr-EDTA and endogenous markers with Sapirstein’s method as a reference standard

2010 ◽  
Vol 14 (6) ◽  
pp. 786-795 ◽  
Author(s):  
Georg Berding ◽  
Siegfried Geisler ◽  
Michael Melter ◽  
Patricia Marquardt ◽  
Astrid Lühr ◽  
...  
2008 ◽  
Vol 65 (10) ◽  
pp. 729-732 ◽  
Author(s):  
Marija Dopudja ◽  
Boris Ajdinovic ◽  
Ljiljana Jaukovic ◽  
Marijana Petrovic ◽  
Zoran Jankovic

Background/Aim. The most frequent method for the assessment of glomerular filtration rate GFR) in clinical practice is clearance of creatinine, clearance of chromium-51 radiolabelled ethylene diamine tetraacetic acid (51Cr-EDTA) and clearance of technetium-99m radiolabelled diethylene triamine pentaacetic acid (99mTc-DTPA). The Gates method for glomerular filtration rate assessment is based on distribution of 99mTc-DTPA in the kidney 2-3 minute after its applying. Calculation of GFR is corrected for the background and depth of the kidney and finally expressed as a percentage of the net injected counts. This value of GFR highly correlates with biexponential model as the most accurate method for the assessment of GFR. The aim of this study was to determine the influence of different background sites on GFR rate assessment using the Gates method. Methods. We analysed 50 patients who were divided into two groups: the group of healthy subjects (21 subjects, mean age 47.38 yrs) and the group of subjects with unilateral kidney damage (29 subjects, mean age 39.79 yrs). Three different background activity regions were chosen: a region drawn below the lower pole of each kidney, region drawn by the lateral side of each kidney and region drawn around the whole kidney. Results. Gromerular filtration rate calculated by the use of a region under the lower pole is statistically significantly higher than GFR calculated using a region by the lateral side and around the whole kidney (p < 0.0001). Glomerular filtration rate calculated using the region by the lateral side and region around the whole kidney did not show statistically significant difference (p > 0.05). Conclusion. The selection of background activity region has a significant influence on GFR rate measured by the Gates method. It is recommended to use only one method for choosing the region of background activity.


2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Chee Keong Thye ◽  
Yee Wan Lee ◽  
Maisarah Jalalonmuhali ◽  
Soo Kun Lim ◽  
Kok Peng Ng

Abstract Background and Aims All living kidney donors undergo assessment of renal function by evaluation of Glomerular Filtration Rate (GFR). 51Cr-EDTA is one of the most widely used marker for measuring GFR but it is hampered by cost and laboriousness as well as not being widely available in Malaysia. Measuring 24-hour urine for creatinine clearance (Ccr) is a common alternative when exogenous filtration markers are not available. Ccr suffers from over/underestimation of measured GFR (mGFR) due to errors in urine collection and tubular secretion of creatinine. This is a study to compare the correlation of Ccr against 51Cr-EDTA in measuring GFR among the living donors in Malaysian population. Method This is a cross-sectional, single-centre study of a cohort of living kidney donor candidates from January 2007 to March 2019. All candidates who had mGFR done with both 51Cr-EDTA and Ccr in University Malaya Medical Centre were enrolled. Special consideration was taken to account for adequate urine sampling for Ccr. Clinical data was analysed for correlation, bias, precision and accuracy between Ccr and 51Cr-EDTA. Results A total of 83 living kidney donors with a mean age of 45.60 ± 11.06 years and body mass index (BMI) of 24.36 ± 4.03 were enrolled. Female comprised 74.7% of the donors while Chinese, Malay and Indian accounted for 67.5%, 20.5% and 7.2% of the donors respectively. The study group had a mean serum creatinine of 63.37 ± 16.00 umol/L with a urine volume of 2.03 ± 0.81 L (range 0.70 – 3.82). mGFR from 51Cr-EDTA was 125.56 ± 27.64 ml/min/1.73m2 (range 77.0 – 194.3) whereas calculated Ccr was 136.05 ± 36.15 ml/min/1.73m2 (range 75.32 – 280.06). The correlation coefficient between Ccr and 51Cr-EDTA is moderate (r = 0.43) (p &lt; 0.01). Mean absolute bias between Ccr and 51Cr-EDTA was 10.59 ± 37.99 ml/min/1.73m2 (p &lt; 0.05). The accuracy of Ccr within 30% of 51Cr-EDTA was 77.11%. Conclusion Our study showed that Ccr significantly overestimates mGFR compared to 51Cr-EDTA. However, there is a significantly moderate positive correlation between Ccr and 51Cr-EDTA. Thus, in the absence of 51Cr-EDTA, Ccr is a clinically acceptable alternative if utilized with care and understanding its limitations.


Sign in / Sign up

Export Citation Format

Share Document