scholarly journals The all-ceramic, inlay supported fixed partial denture. Part 3. Experimental approach for validating the finite element analysis

2012 ◽  
Vol 57 (1) ◽  
pp. 23-30 ◽  
Author(s):  
MC Thompson ◽  
CJ Field ◽  
MV Swain
Ceramics ◽  
2021 ◽  
Vol 4 (2) ◽  
pp. 199-207
Author(s):  
Lohitha Kalluri ◽  
Bernard Seale ◽  
Megha Satpathy ◽  
Josephine F. Esquivel-Upshaw ◽  
Yuanyuan Duan

This study was performed as an adjunct to an existing clinical study to validate the effect of veneer: framework thickness ratio on stress distribution in an implant-supported all-ceramic fixed partial denture. Two commercially available titanium dental implants with corresponding customized abutments and a patient-retrieved all-ceramic fixed partial denture were scanned using a high-resolution micro-CT scanner. Reconstructed 3D objects, along with a simulated bone surface, were incorporated into a non-manifold assembly and meshed simultaneously using Simpleware software (Synopsys Simpleware ScanIP Version P-2019.09; Mountain View, CA). Three such volume meshes (Model A, Model B, Model C) corresponding to veneer: framework thickness ratios of 3:1, 1:1, and 1:3 respectively were created, and exported to a finite element analysis software (ABAQUS). An axial load of 110 N was applied uniformly on the occlusal surfaces to calculate the static stresses and contour plots were generated in the post-processing module. From the data obtained, we observed optimum stress distribution in Model B. Also, the tensile stresses were concentrated in the posterior connector region of the prosthesis in all three models tested. Within the limitations of this study, we can conclude that equal thickness of veneer and framework layers would aid in better stress distribution.


2009 ◽  
Vol 5 (4) ◽  
pp. 1349-1355 ◽  
Author(s):  
Marc Philipp Dittmer ◽  
Philipp Kohorst ◽  
Lothar Borchers ◽  
Meike Stiesch-Scholz

2015 ◽  
Vol 56 (4) ◽  
pp. 215-222 ◽  
Author(s):  
Syuntaro Nomoto ◽  
Satoru Matsunaga ◽  
Toru Sato ◽  
Mamoru Yotsuya ◽  
Shinichi Abe

2016 ◽  
Vol 61 (2) ◽  
pp. 843-846 ◽  
Author(s):  
J. Żmudzki ◽  
P. Malara ◽  
G. Chladek

Abstract Implant and a tooth supported dentures are avoided by dentists because of uneven distribution of occlusal loads between a stiffer implant and a more pliable tooth. The hypothesis was that a 3-point all-ceramic bridge supported on a natural second premolar tooth and a two-pieces typical implant bears safely mastication loads. The finite element analysis showed that the implant splinted by all-ceramic zirconium bridge with the second premolar was safe under lateral mastication load, but there was found an overload at wide zone of bone tissue around the implant under the load of 800 N. The patients can safely masticate, but comminution of hard food should be avoided and they should be instructed that after such an indiscretion they need to contact a dental professional, because, in spite of integrity of the prosthesis, the bone tissue around the implant may fail and there is a hazard of intrusion of the tooth.


Sign in / Sign up

Export Citation Format

Share Document