Preoperative Thoracic Spine Magnetic Resonance Imaging for Spinal Cord Stimulation: Should Such a Recommendation Be an Absolute Requirement?

Author(s):  
Benjamin J. Best ◽  
Mokshal H. Porwal ◽  
Peter A. Pahapill
Pain ◽  
1997 ◽  
Vol 70 (1) ◽  
pp. 95-97 ◽  
Author(s):  
Liong A Liem ◽  
Vincent C.P.C van Dongen

2013 ◽  
Vol 3;16 (3;5) ◽  
pp. E295-E300
Author(s):  
Thomas T. Simopoulos

Background: The use of magnetic resonance imaging (MRI) is continuously escalating for the evaluation of patients with persistent pain following lumbar spine surgery (LSS). Spinal cord stimulation (SCS) therapy is being clinically applied much more commonly for the management of chronic pain following LSS. There is an increased probability that these 2 incompatible modalities may be accidentally used in the same patient. Objectives: The purpose of this case report is to: (1) summarize a case in which a patient with a thoracic spinal cord stimulator underwent a diagnostic lumbar MRI, (2) describe the 3 magnetic fields used to generate images and their interactions with SCS devices, and (3) summarize the present literature. Study design: Case report. Setting: University hospital. Results: Aside from mild heat sensations in the generator/pocket site and very low intensity shocking sensations in the back while in the MRI scanner, the patient emerged from the study with no clinically detected adverse events. Subsequent activation of the SCS device would result in a brief intense shocking sensation. This persisted whenever the device was activated and required Implantable Pulse Generator (IPG) replacement. Electrical analysis revealed that some of the output circuitry switches, which regulate IPG stimulation and capacitor charge balancing, were damaged, most likely by MRI radiofrequency injected current. Limitations: Single case of a patient with a thoracic SCS having a lumbar MRI study. Conclusion: This case demonstrates the lack of compatibility of lumbar MRI and the Precision SCS system as well as one of the possible patient adverse events that can occur when patients are exposed to MRI outside of the approved device labeling. Key words: Spinal cord stimulation devices, magnetic resonance imaging


2019 ◽  
Vol 15 (2) ◽  
pp. 262
Author(s):  
Jeong-Yoon Lee ◽  
Jun-Sang Sunwoo ◽  
Kyum-Yil Kwon ◽  
Kyung Bok Lee ◽  
Moo-Young Ahn ◽  
...  

Neurosurgery ◽  
2014 ◽  
Vol 61 ◽  
pp. 221-222
Author(s):  
Milind Deogaonkar ◽  
Chima Oluigbo ◽  
Dylan Nielson ◽  
Xiangyu Yang ◽  
Mayur Sharma ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document