An Evaluation of Three-Dimensional Diarthrodial Joint Contact Using Penetration Data and the Finite Element Method

2001 ◽  
Vol 123 (4) ◽  
pp. 333-340 ◽  
Author(s):  
W. L. Dunbar, ◽  
K. U¨n ◽  
P. S. Donzelli ◽  
R. L. Spilker

We have developed an approximate method for simulating the three-dimensional contact of soft biphasic tissues in diarthrodial joints under physiological loading. Input to the method includes: (i) kinematic information describing an in vitro joint articulation, measured while the cartilage is deformed under physiological loads, (ii) geometric properties for the relaxed (undeformed) cartilage layers, obtained for the analyses in this study via stereophotogrammetry, and (iii) material parameters for the biphasic constitutive relations used to represent cartilage. Solid models of the relaxed tissue layers are assembled in physiological positions, resulting in a mathematical overlap of the cartilage layers. The overlap distribution is quantified and converted via the biphasic governing equations into applied traction boundary conditions for both the solid and fluid phases for each of the contacting layers. Linear, biphasic, three-dimensional, finite element analysis is performed using the contact boundary conditions derived for each of the contacting layers. The method is found to produce results consistent with the continuity requirements of biphasic contact. Comparison with results from independent, biphasic contact analyses of axisymmetric problems shows that the method slightly underestimates the contact area, leading to an overestimation of the total traction, but yields a good approximation to elastic stress and solid phase displacement.

2005 ◽  
Vol 128 (1) ◽  
pp. 124-130 ◽  
Author(s):  
Kerem Ün ◽  
Robert L. Spilker

In this study, we extend the penetration method, previously introduced to simulate contact of linear hydrated tissues in an efficient manner with the finite element method, to problems of nonlinear biphasic tissues in contact. This paper presents the derivation of contact boundary conditions for a biphasic tissue with hyperelastic solid phase using experimental kinematics data. Validation of the method for calculating these boundary conditions is demonstrated using a canonical biphasic contact problem. The method is then demonstrated on a shoulder joint model with contacting humerus and glenoid tissues. In both the canonical and shoulder examples, the resulting boundary conditions are found to satisfy the kinetic continuity requirements of biphasic contact. These boundary conditions represent input to a three-dimensional nonlinear biphasic finite element analysis; details of that finite element analysis will be presented in a manuscript to follow.


2020 ◽  
Vol 8 (03) ◽  
pp. 084-091
Author(s):  
Himani Jain ◽  
Tarun Kalra ◽  
Manjit Kumar ◽  
Ajay Bansal ◽  
Deepti Jain

Abstract Introduction This study was undertaken to assess the influence of different superstructure materials, when subjected to occlusal loading, on the pattern of stress distribution in tooth-supported, implant-supported, and tooth implant-supported fixed partial prostheses, using the finite element analysis with a comparative viewpoint. Materials and Methods The geometric models of implant and mandibular bone were generated. Three models were created in accordance with the need of the study. The first model was given a tooth-supported fixed partial prosthesis. The second model was given tooth implant-supported fixed partial prosthesis, and the third model was given implant-supported fixed partial prosthesis. Forces of 100 N and 50 N were applied axially and buccolingually, respectively. Results The present study compared the stresses arising in the natural tooth, implant, and the whole prostheses under simulated axial and buccolingual loading of three types of fixed partial dentures, namely, tooth-supported, tooth implant-supported, and implant-supported fixed partial dental prostheses using three different types of materials. Conclusion The pattern of stress distribution did not appear to be significantly affected by the type of prosthesis materials in all models. The maximum stress concentrations were found in the alveolar bone around the neck of the teeth and implants.


2018 ◽  
Vol 29 (20) ◽  
pp. 3902-3922 ◽  
Author(s):  
Nguyen Van Viet ◽  
Wael Zaki ◽  
Rehan Umer

We propose a new analytical model for a superelastic shape memory alloy prismatic cantilever beam subjected to a concentrated force at the tip. The force is gradually increased and then removed and the corresponding distribution of phase transformation fields in the beam is determined, analytically, in both the transverse and longitudinal directions. Analytical moment–curvature and shear force–shear strain relations are also derived during loading and unloading of the beam. The proposed model is validated against an exact numerical beam model as well as a three-dimensional finite element analysis model for the same beam, with very good agreement in each case. Moreover, an experiment is proposed and carried out to characterize the load–deflection response of a shape memory alloy beam under the same boundary conditions as those considered in deriving the model. The obtained response is in good agreement with the analytical model as well as three-dimensional finite element analysis simulations. The analytical method provides a direct mathematical way for describing the material and structural properties of the beam and the distribution of the different solid phase regions as they change under the influence of an applied load and allows the determination of details such as the boundaries of solid phase regions immediately and accurately using equations. The same would require postprocessing at possibly significant computational cost and personal effort if finite element analysis or similar numerical methods are used.


Sign in / Sign up

Export Citation Format

Share Document