Peripheral dose measurements for 6 and 18MV photon beams on a linear accelerator with multileaf collimator

2008 ◽  
Vol 35 (10) ◽  
pp. 4396-4403 ◽  
Author(s):  
Michalis Mazonakis ◽  
Fotini Zacharopoulou ◽  
Haralambos Varveris ◽  
John Damilakis
2006 ◽  
Vol 11 (6) ◽  
pp. 281-285 ◽  
Author(s):  
R. Balasubramanian ◽  
P. Sellakumar ◽  
Ramesh S. Bilimagga ◽  
Sanjay S. Supe ◽  
B.N. Sankar

2017 ◽  
Vol 23 (4) ◽  
pp. 115-119 ◽  
Author(s):  
Md Abdullah Al Mashud ◽  
M Tariquzzaman ◽  
M Jahangir Alam ◽  
GA Zakaria

Abstract The aim of this study is to present the results of commissioning of Elekta Synergy linear accelerator (linac). The acceptance test and commissioning were performed for three photon beams energies 4 MV, 6 MV and 15 MV and for the multileaf collimator (MLC). The percent depth doses (PDDs), in-plane and cross-plane beam profiles, head scatter factors (Sc), relative photon output factors (Scp), universal wedge transmission factor and MLC transmission factors were measured. The size of gantry, collimator, and couch isocenter were also measured.


1999 ◽  
Vol 26 (9) ◽  
pp. 1874-1882 ◽  
Author(s):  
K. De Vlamynck ◽  
H. Palmans ◽  
F. Verhaegen ◽  
C. De Wagter ◽  
W. De Neve ◽  
...  

2008 ◽  
Vol 33 (3) ◽  
pp. 114 ◽  
Author(s):  
R Mohan ◽  
K Jayesh ◽  
RC Joshi ◽  
Maha Al-idrisi ◽  
P Narayanamurthy ◽  
...  

2019 ◽  
Vol 9 (2Apr) ◽  
Author(s):  
A Kajaria ◽  
N Sharma ◽  
Sh Sharma ◽  
S Pradhan ◽  
A Mandal ◽  
...  

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosimetric features including lateral profiles, central axis depth dose, photon and electron spectra were calculated for flattened and unflattened cases, separately.Results: An increase in absolute depth dose with a factor of more than 2.4 was observed for unflattened beam which was dependent on depth. PDDs values were found to be lower for unflattened beam for all field sizes. Significant decrease in calculated mlc leakage was observed when the flattening filter was removed from the beam line. The total scatter factor, SCP was found to show less variation with field sizes for unflattened beam indicating a decrease in head scatter. The beam profiles for unflattened case are found to have lower relative dose value in comparison with flattened beam near the field edge, and it falls off faster with distance.Conclusion: Our study showed that increase in the dose rate and lower peripheral dose could be considered as realistic advantages for unflattened 6MV photon beams.


2008 ◽  
Vol 35 (2) ◽  
pp. 464-472 ◽  
Author(s):  
Giorgia Nicolini ◽  
Antonella Fogliata ◽  
Eugenio Vanetti ◽  
Alessandro Clivio ◽  
Daniel Vetterli ◽  
...  