SU-E-T-85: Total Body Irradiation (TBI) Optically Stimulated Luminescence In Vivo Dosimetry

2013 ◽  
Vol 40 (6Part11) ◽  
pp. 223-223 ◽  
Author(s):  
C Holloway ◽  
S Mahendra ◽  
D Kaurin ◽  
L Sweeney
Blood ◽  
2013 ◽  
Vol 122 (21) ◽  
pp. 4565-4565
Author(s):  
Sebastian Giebel ◽  
Leszek Miszczyk ◽  
Krzysztof Slosarek ◽  
Leila Moukhtari ◽  
Fabio Ciceri ◽  
...  

Background Total body irradiation (TBI) is widely used for conditioning prior to both allogeneic and autologous hematopoietic stem cell transplantation. Myeloablatitve doses of TBI are considered highly effective but also associated with relevant toxicity. Both, the efficacy and toxicity may depend on many methodological aspects of TBI. The goal of the survey was to explore current practice across centers collaborating in the European Group for Blood and Marrow Transplantation (EBMT). Methods The questionnaire sent to all EBMT centers included 19 questions regarding the doses used for myeloabaltive TBI, the way of fractionation, the modes of delivering the dose, type of immobilization, methods of dosimetry and organ shielding. 56 centers from 23 countries responded. Results All centers differ with regard at least one of the methodological aspects. The total dose of TBI used for myeloablative transplantation ranges from 8 to 14.4 Gy, the number of fractions ranges from 1 to 8, while the dose per fraction is 1.65 – 8 Gy. Altogether 16 modalities of dosing/fractionation have been identified with 6 x 2 Gy being the most frequent one (n=36, 64%). The dose rate in the axis of the beam ranges from 4.5 – 30 cGy/min (27 modalities; most frequently 18 cGy/min, 5%). The treatment unit is regular linac (n=51, 91%) or cobalt unit (n=5, 9%). Beams used for regular linac are 6 to 23 MV (most frequently 6 MV, n=26, 51%). The most frequent technique used for irradiation is “patient in one field” using two fields per fraction and two patient positions per fraction (n=36, 64%), however, altogether 11 modalities were described with regard to the technique, number of fields and positions per fraction. Source to surface distance is 2 to 5 m (most frequently 4 m; n=10, 18%). In 23 (41%) centers patients are immobilized during TBI, using 9 different types of device. Fifty-two centers (93%) measure acquired dose of irradiation using 5 types of detectors for in vivo dosimetry (most frequently semiconductors; n=37, 66%). Accepted discrepancy between planned and measured dose ranges from 1.5 to 10%. In 47 (84%) centers lungs are shielded during irradiation and lung density is considered for treatment planning. Maximum accepted dose for lungs ranges from 6 to 12 Gy. Additionally, in some centers lenses (14%), thyroid gland (7%), larynx (4%), kidneys (4%) and/or salivary glands (2%) are shielded. Conclusions TBI is an extremely heterogeneous treatment modality. Differences between centers regard all methodological aspects. Our findings should warrant caution in interpretation of clinical studies involving TBI. Further investigation is needed to evaluate whether differences between treatment modalities influence the efficacy and safety of the TBI procedure. Finally, efforts to standardize the method should be considered. Disclosures: No relevant conflicts of interest to declare.


2005 ◽  
Vol 32 (6Part9) ◽  
pp. 1996-1996 ◽  
Author(s):  
TM Briere ◽  
RC Tailor ◽  
NB Tolani ◽  
KL Prado ◽  
RG Lane ◽  
...  

2014 ◽  
Vol 39 (4) ◽  
pp. 354-359 ◽  
Author(s):  
David J. Eaton ◽  
Alison J. Warry ◽  
Rachel E. Trimble ◽  
Maria J. Vilarino-Varela ◽  
Christopher H. Collis

2012 ◽  
Vol 37 (4) ◽  
pp. 214 ◽  
Author(s):  
K Ganapathy ◽  
P. G. G. Kurup ◽  
V Murali ◽  
M Muthukumaran ◽  
N Bhuvaneshwari ◽  
...  

2020 ◽  
Vol 61 (6) ◽  
pp. 959-968
Author(s):  
Yuichi Akino ◽  
Shintaro Maruoka ◽  
Katsuyuki Yano ◽  
Hiroshi Abe ◽  
Fumiaki Isohashi ◽  
...  

Abstract The goal of total body irradiation (TBI) is to deliver a dose to the whole body with uniformity within ±10%. The purpose of this study was to establish the technique of TBI using plastic bead bags. A lifting TBI bed, Model ORP-TBI-MN, was used. The space between the patient’s body and the acrylic walls of the bed was filled with polyacetal bead bags. Patients were irradiated by a 10 MV photon beam with a source to mid-plane distance of 400 cm. The monitor unit (MU) was calculated by dose-per-MU, tissue-phantom-ratio and a spoiler factor measured in solid water using an ionization chamber. The phantom-scatter correction factor, off-center ratio and the effective density of the beads were also measured. Diode detectors were used for in vivo dosimetry (IVD). The effective density of the beads was 0.90 ± 0.09. The point doses calculated in an I’mRT phantom with and without heterogeneity material showed good agreement, with measurements within 3%. An end-to-end test was performed using a RANDO phantom. The mean ± SD (range) of the differences between the calculated and IVD-measured mid-plane doses was 1.1 ± 4.8% (−5.9 to 5.0%). The differences between the IVD-measured doses and the doses calculated with Acuros XB of the Eclipse treatment planning system (TPS) were within 5%. For two patients treated with this method, the differences between the calculated and IVD-measured doses were within ±6% when excluding the chest region. We have established the technique of TBI using plastic bead bags. The TPS may be useful to roughly estimate patient dose.


Author(s):  
Eilen Llanes Veiga ◽  
Rodolfo Alfonso Laguardia ◽  
Roberto Caballero Pinelo

Sign in / Sign up

Export Citation Format

Share Document