Crystallization in a saturated magma Part II (Example) A three phase equilibrium approach to the Bishop Tuff

Author(s):  
Eugenio Aragón
2016 ◽  
Vol 873 ◽  
pp. 18-22
Author(s):  
Ming Li Huang ◽  
Xue Shen ◽  
Hong Xiao Li

The equilibrium alloys closed to Mg-Nd side in the Mg-rich corner of the Mg-Zn-Nd system at 400°C have been investigated by scanning electron microscopy, electron probe microanalysis and X-ray diffraction. The binary solid solutions Mg12Nd and Mg3Nd with the solubility of Zn have been identified. The maximum solubility of Zn in Mg12Nd is 4.8at%, and Mg12Nd phase can be in equilibrium with Mg solid solution. However, only when the solubility range of Zn in 26at%~32.2at%, Mg3Nd can be in two-phase equilibrium with Mg solid solution. As the results, two two-phase regions as Mg+Mg12Nd and Mg+Mg3Nd and a three-phase region as Mg+Mg12Nd+Mg3Nd in Mg-Nd-Zn ternary isothermal section at 400°C have been identified.


2007 ◽  
Author(s):  
Abbas Firoozabadi ◽  
Kjetil Braathen Haugen ◽  
Lixin Sun

CORROSION ◽  
1956 ◽  
Vol 12 (11) ◽  
pp. 23-32 ◽  
Author(s):  
W. K. FOSTER ◽  
M. H. LEIPOLD ◽  
T. S. SHEVLIN

2019 ◽  
Vol 173 ◽  
pp. 525-535
Author(s):  
Ehsan Ranjbar ◽  
Seyyed M. Ghaderi ◽  
Hossein Nourozieh ◽  
Anjani Kumar ◽  
Ali Takbiri-Borujeni

Electronics ◽  
2018 ◽  
Vol 7 (9) ◽  
pp. 167 ◽  
Author(s):  
Jin-Wook Kang ◽  
Seung-Wook Hyun ◽  
Jae-Ok Ha ◽  
Chung-Yuen Won

This paper investigates the fault-tolerance control of a multilevel cascaded NPC/H-bridge (CNHB) inverter. The fault-tolerance control method has been widely used for multilevel inverters, such as the neutral-point voltage-shifting control, which can operate for a certain period of time by compensating for the phase voltage of a faulty stack even if one stack is broken. Even though the three-phase equilibrium is maintained in the case of failure by using the conventional neutral-point voltage-shifting control, an imbalance in the output power occurs between each stack, which causes problems for maintenance and lifetime. Therefore, this paper proposes a fault-tolerance control that can maintain three-phase equilibrium in a case of stack failures and minimize power imbalances between the stacks. The problem of the conventional neutral-point voltage-shifting control is presented based on the output power. In addition, the power imbalance is improved by performing selective neutral-point voltage-shifting control according to the reference voltage range. To verify the principle and feasibility of the proposed neutral-point voltage-shifting control method, a simulation and an experiment are implemented with the CNHB inverter.


Sign in / Sign up

Export Citation Format

Share Document