Fabrication of Zn(II) Selective Polyvinyl Chloride Membrane Electrode based on N,N'-bis(1-hydroxynaphthalene-2-carbaldehyde)-o-phenylenediamine as an Ionophore: Experimental and Theoretical Approaches

2019 ◽  
Vol 74 (2) ◽  
pp. 134-142 ◽  
Author(s):  
Karamjeet Kaur ◽  
Jatinder Singh Aulakh ◽  
Ashok Kumar Malik
1991 ◽  
Vol 40 (1) ◽  
pp. 1-6 ◽  
Author(s):  
Takashi MASADOME ◽  
Toshihiko IMATO ◽  
Nobuhiko ISHIBASHI

2020 ◽  
Vol 40 (6) ◽  
pp. 481-485 ◽  
Author(s):  
Shankar Suman ◽  
Ram Singh

AbstractA synthesized Schiff base 2-acetylthiophene semicarbazone (3) was used for the preparation of Ni2+ selective polyvinyl chloride (PVC) membrane electrode. The prepared electrode with the optimized composition, PVC:3:sodium tetraphenylborate:di-n-butylphthalate as 33:6:3:58 exhibited a Nernstian response over the working range of 5.0 × 10−6–5.0 × 10−2 mol l−1 with a slope of 29.0 ± 0.3 mV/concentration. The electrode showed good selectivity towards Ni2+ with respect to several metal ions in the pH range of 2.5–10.0 in <15 s with a detection limit of 4.7 × 10−6 mol l−1. The electrode showed the additional benefit of working in partially nonaqueous media having up to 15% (v/v) methanol or ethanol. This electrode was also successfully applied in Ni2+ ion potentiometric titration with ethylenediaminetetraacetic acid as an indicator electrode.


2014 ◽  
Vol 92 (4) ◽  
pp. 324-328 ◽  
Author(s):  
Muberra Andac ◽  
Fatih Coldur ◽  
Seda Bilir ◽  
Aysenur Birinci ◽  
Serkan Demir ◽  
...  

A miniaturized solid-contact polyvinyl chloride membrane electrode based on the bis[(2-(hydroxyethylimino)phenolato]copper(II) complex has been prepared for the determination of Cu(II) ion in real samples. The influence of coating membrane composition, pH, and possible interfering cations on the response of the ion-selective electrode was investigated. A number of membranes at different compositions were prepared and their Cu2+ sensing capabilities were investigated. The best results for Cu2+ sensing was obtained for the electrode membrane containing ionophore − 2-nitrophenyloctyl ether – polyvinyl chloride and potassium tetrakis(p-chlorophenyl)borate in a ratio of 4:65:30:1 (w/w, mg), respectively. The prepared electrode exhibited a near-Nernstian response (28.3 mV/decade) to Cu2+ in the concentration range from 1.0 × 10−6 to 1.0 × 10−1 mol/L with a limit of detection of 8.3 × 10−7 mol/L. The potentiometric response of the electrode was independent from the pH of the test solution in the pH range of 3.0–6.0. The electrode has a very short response time, about 15 s, and it can be used over a period of 3 months without any divergence in potential. The electrode has been successfully applied as an indicator electrode in potentiometric titration of Cu(II) ions with ethylenediaminetetraacetic acid and in the determination of Cu(II) in wastewater of the copper processing industry.


2017 ◽  
Vol 35 (9) ◽  
pp. 934-940
Author(s):  
Jingui HE ◽  
Yong LI ◽  
Xiangxin XUE ◽  
Hongqiang RU ◽  
Xiaowei HUANG ◽  
...  

2000 ◽  
Vol 35 (13) ◽  
pp. 1979-1990 ◽  
Author(s):  
YUKIO SAKAI ◽  
ROBERT W. CATTRALL ◽  
IAN D. POTTER ◽  
SPAS D. KOLEV ◽  
ROHANI PAIMIN

Sign in / Sign up

Export Citation Format

Share Document