Feasibility study of 8-MeV H− cyclotron to charge the electron cooling system for HESR

2008 ◽  
Vol 5 (2) ◽  
pp. 107-115
Author(s):  
V. Parkhomchuk ◽  
A. Papash
2021 ◽  
Vol 32 (10) ◽  
Author(s):  
Mei-Tang Tang ◽  
Li-Jun Mao ◽  
Hai-Jiao Lu ◽  
Li-Xia Zhao ◽  
Jie Li ◽  
...  

2016 ◽  
Vol 36 (1) ◽  
pp. 6-13
Author(s):  
Leonardo Frizziero ◽  
Luca Piancastelli

<p>A feasibility study for the installation of a CRDID (Common Rail Direct Injection Diesel) on a light helicopter is introduced. The total mass available for the CRDID is evaluated starting from fuel consumption and helicopter data. The conversion of an automotive unit was discarded to excessive mass and excessive costs of the conversion. A derivative of an automotive engine was then considered. This solution proved to be feasible. The installation of the new CRDID was then studied. The turbocharger and the cooling system were defined for the application. The result was the evaluation of the power plant installation mass that proved to be much lower than the maximum admissible. The installation is then possible.</p>


Author(s):  
Yu Korotaev ◽  
I Meshkov ◽  
A Petrov ◽  
A Sidorin ◽  
A Smirnov ◽  
...  

Author(s):  
S. Nagaitsev ◽  
D. Broemmelsiek ◽  
A. Burov ◽  
K. Carlson ◽  
C. Gattuso ◽  
...  

Author(s):  
E.I Antokhin ◽  
V.N Bocharov ◽  
A.V Bubley ◽  
A.D Goncharov ◽  
B.I Grishanov ◽  
...  

Author(s):  
Jae Dong Chung ◽  
Yoon-Pyo Lee ◽  
Hoseon Yoo ◽  
Jae-Heon Lee ◽  
Chang-Jun Lee ◽  
...  

The district-cooling system (DCS) was in service in Sang-am in Seoul, Korea after 2005. The facility capacity of the DCS in Sang-am is 111Gcal/h at 2011 and 63Gcal/h of facility is planned to install till 2025. However, the cooling demand is increased due to new high-rise building blocks, and the required facility capacity is expected to be 101Gcal/h. A difficulty comes from building new plan in the existing plant. This paper is on the feasibility study for the new requirement under the restrictions of existing pipeline, limited space and regulation on the usage of electric driven chiller. Precise estimation of the diversity factor is essential to determine the required capacities. For this, every building in the area was categorized and the cooling loads were measured for the summer seasons of 2010 and 2011. The large energy capacity of ice slurry can potentially increase the cooling capacity in existing plants while maintaining the same flow rate and pumping power. Thus under the restriction of existing pipeline system, introducing ice slurry is expected as potential solution to the significantly increased cooling load without requiring increases in pipe size or system flow rates.


2016 ◽  
Vol 13 (7) ◽  
pp. 792-795
Author(s):  
M. I. Bryzgunov ◽  
A. V. Bubley ◽  
A. D. Goncharov ◽  
V. M. Panasyuk ◽  
V. V. Parkhomchuk ◽  
...  

Author(s):  
Y. Gao ◽  
W. Lin ◽  
K. A. Brown ◽  
X. Gu ◽  
G. H. Hoffstaetter ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document